PMT18-01149 City of Menifee Permit No.: PMT18-01149
29714 HAUN RD.
�/►C.CEL.A? MENIFEE, CA 92586 Type: Residential Plumbing
MENIFEE Date Issued: 03114/2018
PERMIT
Site Address: 28704 ERIDANUS DR, MENIFEE, CA Parcel Number: 339-272-020
92586 Construction Cost: $1,213.00
Existing Use: Proposed Use:
Description of REPLACE 40 GAL GAS WATER HEATER IN GARAGE, BRADFORD WHITE URG140T6N
Work:
Owner Contractor
KATHLEEN MOORE WATER HEATERS ONLY INC
28704 ERIDANUS DR 970 E MAIN STREET#200
MENIFEE, CA 92586 GRASS VALLEY, CA 95945
Applicant Phone:8008358345
STEVEN SCHNIERER License Number: 374573
WATER HEATERS ONLY INC
970 E MAIN STREET#200
GRASS VALLEY, CA 95945
Fee Description -Ott Amount($)
Residential Water Heater 1 83.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
General Plan Maintenance Fee- Plumbing 1 4.15
$115.15
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpl Page 1 of 1
Wa4er "¢-'C¢ DrIl1y CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter!)(commencing with section 7000)of Division 3 of the Business and o I am exempt from licensure under the Contractors State License Law for
Professions Code and my license is in full force and effect. the following reason:
License Class 3t License No. 3-N-S-7 By my signature below 1 acknowledge that,except for my personal residence
Expires S 3111 9 Signature ...-,.z� 1 in which I must have resided for at least one year prior to completion of
WORKER'S COMPENSATION DECLARATION improvements covered by this permit.I cannot legally sell a structure that I
have built as an owner-builder if it has not been constructed in its entirety by
�- hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
6e and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,Is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which www.leginfo.ca.gov/calaw.htmi.permit is issued.
Policy# y_S'il�c7'-✓•-q Date
o I have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT
section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property
this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this
number are: application and the information I have provided is correct.I agree to comply
with all applicable city and county ordinances and state laws relating to
Carrier building construction.I authorize representatives of this city or county to
Policy# Expires enter the above identified property for inspection purposes.
(This section need not to be completed is the permit is for one-hundred ��
dollars($100)or less - v� ate
3 / I$
PROPERTY OWNER OR AUTHORIZED AGENT
o I certify that in the performance of the work for which this permit is issued,
I shall not emolov any persons in any manner so as to become subject to the CITY BUSINESS UCENSE# 03 S8S' 5
workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the workers compensation provisions of Section 3700 of the Labor
Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a
Applicant ie - r I S mixture containing a hazardous material equal to or greater that the
amounts�s�ecified on the Hazardous Materials Information Guide?
WARNING:FAILURETO SECUREWORKER'S COMPENSATION COVERAGE IS oYesi�rvo
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYERTO CRIMINAL PENALTIES Will the intended use ofthe building bythe applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,0013),IN occupant require a permit for the construction or modification from South
ADDITIONTOTHE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for gulde'nes
CONSTRUCTION LENDING AGENCY 0Yes No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is issued outer bouJdary of a school?
(Section 3097 Civil Code) o Yes �tfJO
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of
Contractors License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25505 and 25534 concerning
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 zardous material reporting. `
Business and Professions Code).Any city or county that requires a permit to '2
construct,alter,improve,demolish or repair any structure,prior to its -
issuance,also requires the applicant for the permit to file a signed statement PROPERTY OWNER OR AUTHORIZED AGENT
that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING IRRP)
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500). managers who do the paint-disturbing work themselves or through their
❑1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.eov/lead or contact the National Lead Information Center at
not Intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. o No EPA Lead-Safe Certified Firm is required for this project because:
o I,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK
4�y
Menifee
DATE 03/14/2018 PERMIT/PLAN CHECK NUMBER DSO
TYPE: ❑COMMERCIAL F RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑ADDITION ❑ALTERATION [-]DEMOLITION [-]ELECTRICAL []MECHANICAL
❑NEW ❑✓ PLUMBING ❑RE-ROOF-NUMBEROFSQUARES
DESCRIPTION OF WORK Replace 40 gallon gas water heater in garage, Bradford White URG140T6N
PROJECTADDRESS 28704 Eridanus Drive
ASSESSOR'S PARCEL NUMBER 31 - a-to-c)ao LOT TRACT
OWNER NAME Kathleen Moore
ADDRESS 28704 Eridanus Drive Sun City, CA 92586
PHONE (951)756-5094 EMAIL
APPLICANT NAME Steven Schnierer
ADDRESS 31225 La Baya Drive Suite 213 Westlake Village,CA 91362
PHONE (818)735-7876 EMAIL swschnierer@roadrunner.com
CONTRACTOR'S NAME Water Heaters Only Inc. OWNER BUILDER? ❑YES❑✓NO
BUSINESS NAME Water Heaters Only Inc.
ADDRESS 970 E Main Street#200 Grass Valley, CA 95945
PHONE (530)274-3001 EMAIL
CONTRACTOR'S STATE LIC NUMBER 374573 LICENSE CLASSIFICATION C36
VALUATION$ $ 1.213.00 SQ FT L SO FT
APPLICANT'S SIGNATURE DATE 0 3/1 412 0 1 8
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUNNE55 LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE I GREEN P SMIP
INVOICE 1
AMOUNT II�5
,115 PAID AMOUNT
O CASH O CHECK# O CREDR CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT OCASH OCHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
mm
" o, W
W w ha C. " O ' _ m ' m 1° rC F+ N a m ti m A o b
.s o. m m mmb. _ » 3w -. -I a Z 1
YGGu CCam" 1° N' 2' wmS. 0 c N � tyiZF .
M o T u b y O ui n a N n _ ry A
c > Z a0 ns.
'4
N 0 .m.3 w ' 2
a o m w £ d m. .u. N n 3 O (o�
DO
..�
mom ? ap o • � uum` m Z o him Q
m n
o
3
w
• ti �• ' .N 1 � M < c O N m m
m N ro J j N fi 1 N
p Tom' m m o S3 r•' Sa
3 m d 3
M W C7
° rn <�do z C•`G
3 m N m m u g
T) � w
o
E t a cm
u gn;N = axo _ -O -Et
p1 '—' oo •' fD
EL
CL
i
m N '
.. .Z' r 'J'
o
a n `.w u
N
h
p - n_ n..ti -n •n .7
n .R
N 1. •'N. lm'•
A 0 0 m A
w w s
w' 3
,ilk/���/ 0�� ■
NN la b ry Z ya y �+b m < +F m 'loll A Lf N 1+ O l0 6l J dl UI A O T
A 9 �i. G�SI j O ? b m a L ID G4 ° G iq r�fi
x
- O1 ` 0° rvIq
2 OT
if
'n m y� a � = � o• � n •c •e m o w c m
- - � A, �•. O � c -� n o d e " m b m i N `" oq = m o. Inif
F — O
_ - � O 'm Z' h � .c g •* m 3 s a 3 v- " i n c m
EL
3 d c m 01 � °.m Y -^ , •e w 2
a A o b » n w m C c 5 °
w j N
'° C m w oe w
O S m o °uN9 m H 3 3
.w "_11 4' m � S ° � u O `e S3 � � •c in _ i � c�i
• T.. a » � w nH '�° m me owm af3
w m of —y m z c s a :;� ^' c
c' T w
'C °
eL
•f, u P6m- o cl_ 2r 0Gr
w
ur
w m w N . �• u
RL
lm Ur
ma
N
m .o- m
' J n
Vim] w 0 5 0 3 m 'o
.w d 6 .E N C m.
N
m
o' b
. �R
06144
BRADFORD WHITE®
W A T E R H E A T E R S City of Menifee
Residential Ultra Low NOx Building Dept.
Gas Water Heater MAR 1 4 2018
=k: The FVIR Eco-Defender Safety System°Models Feature: ^ A,y
T T�ICE r: ■ Bradford White ICON System"—Intelligent gas control with tl wee nology
and built-in piezo igniter.A standard,off the shelf thermopile n h t energy from the pilot
-- —1 flame into electrical energy to operate the gas valve and microprocessor.No need for external
electricity.
— Enhanced Performance—Proprietary algorithms provide enhanced First Hour Rating and tighter
temperature differential.
—Advanced Temperature Control System—Microprocessor constantly monitors and controls
burner operation to maintain consistent and accurate water temperature levels.
— Intelligent Diagnostics—An exclusive green LED light prompts the installer during start-up and
provides ten different diagnostic codes to assist in troubleshooting.
— Pilot On Indication—Flashing green LED provides positive indication that pilot is on.
—Separate Immersed Thernowell—High-strength advanced polymer composite thermowell
provides isolation between electric temperature sensor and surrounding water.No need to drain
the tank when removing gas valve.
■ Defender Combustion Chamber—Incorporates the Advanced ScreenLok•Technology Flame
Arrestor and large split-door design to prevent ignition of flammable vapors outside the water heater.
■ Ultra Low NOx Burner with Primary and Secondary Air Distribution Devices—Ensures proper
air to gas ratio for reduction of NOx generated by the combustion process.
■ Digital Thermal Sensor and Resettable Thermal Switch—Coordinates with self diagnostic
control to prevent water heater operation when needed.
■ Maintenance-Free—No regular cleaning of air inlet openings or flame arrestor is required under
normal conditions.
■ Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and
burner.
'g _ ■ Factory-Installed Hydrojet"Total Performance System—Sediment reducing device that also
Increases first hour rating of hot water while minimizing temperature build-up In tank.
"_��• �' ■ Vitro las•Lining—An An exclusive) engineered enamel formula that provides superior tank protection
�� �...../ 9 9— Y 9 P P
r:,r from the highly corrosive effects of hot water.This formula(Vitraglas's)is fused to the steel surface by
l jl 6 l firing at a temperature of over 1600°F(871"C).
■ Insulation System—Non-CFC foam covers the sides and top of the tank,reducing heat loss.This
results in less energy consumption,improved efficiencies,and jacket rigidity.
Photo is of ■ Pedestal Base—Rugged and durable base allows easy transport and positioning and corrosion-
resistant contact with floor.
■ Water Connections--V4"(19mm)NPT factory-installed true dielectric fittings extend water heater
life and simplify water line connections.
■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in piping
and eliminates the potential for noise generation.
■ Protective Magnesium Anode Rod—Provides added protection against corrosion for long-term,
trouble-free service.
FEATURING: - --- _-- ■ 3x4"Snap Lock"Draft Diverter—Allows either 3"(76mm)or 4" (102mm)vent connections with
inputs of 40,000 BTU/Hr.or less.Over 40,000 BTU/Hr.has a 4"(102mm)"Snap Lock"Draft Diverter.
ICON ■ Flue Baffle—Maximizes the amount of heat absorbed by the tank and reduces heat loss during
,system ,°,�_� � standby periods.
°""^'°•"a""" ■ Steel Tank—Heavy gauge steel automatically formed,rolled,and welded.
■ T&P Relief Valve—installed.
■ Low Restrictive Brass Drain Valve—Durable tamper proof design.
■ Design Certified by CSA International(formerly AGA/CGA).
■ Complies with the latest Ultra Low NOx requirement(10 ng/J NOx limit).
a 6 or 10-Year Limited Tank Warranties/6 or 10-Year Limited Warranty on Component Parts.
SA• ® For more information on warranty,please visit www.bradfordwhite.com
Far products installed in USA,Canada,and Puerto Rico.Some states do not allow limitations on warranties.See complete copy
of the warranty included with the heater.
MANUFACTURED UNDER ONE ON MORE OF THE FOLLOWING U.S.PATENTS:5,682,666;7,634.976;5,660,165;5.954.492;6.056.542;6.M.280:5,372,185;5,485.979:5,574,M;7.971,560;7.992.526;6.684.821;
6.442,178;7.334.419;7,866,168;7,270,097;7,007,748;5,596,952;6,142.216;7,699,026;5,341,770:7,337.517:7.665.211;7,665,210;7,063.132;7,063,133;7,559.293:7,900,589;5,943,984;8,082,888;5,988,117;
7,621238;7.650.859;5,761,379;7,409,925;5,277,171;8.146.772;7,458.341;2,262,174.OTHER U.S.AND FOREIGN PATENT APPLICATIONS PENDING.CURRENT CANADIAN PATENTS:2,314,845;2,504,824;2,108,186;
2,143.031;2.409,271;2.548.958;2,112.515;2,476,685;2,239,007;2,092,105:2,107,012.Delender Safety System-.SoreenLok",VlOeglar and Hydroler are registered hademarle of Bradford While-Corporation.
111R_R_011R
ResidentiatAra tow 1V�x Las ater Heater
Ultra Low NOx Models Meet or exceed ASHRAE 911.1b(current standard)C.E.C.Listed
NATURAL GAS Recovery elliciency ranging up to 80%
Model Nominal Recovaryat A B C D E F G Approx.
Number Capacity DOE 90•F Rise' Floor Jacket Vent Floor Floor Floor Depth Shipping
Rated First to Dia. Size to to to Weight
Storage Nat. Hour Uniform Nat. Nat. Flue T&P Gas Water
U.S. Imp. Volume BTU/Hr. Retin Energy U.S. Imp. Conn. Conn. Conn. Conn.
Gal. Gal. (Gal.) Input (Gal.) Factor GPH GPH In. In. in. In. In. in. In. Its.
URG13OT6N- 30 25 29 27,000 46 0.54 29 24 591/8 16 3x4 493/4 1563/8 113A 575h 195/2 112
URG230T6N• 30 25 29 32,000 60 0.60 34 28 59T1a 18 3x4 4971.1563h 113/, 57 2111, 119
URG140T6N• 40 33 38 34,000 64 0.59 37 31 60314 18 3x4 515/2/595/2 11 ah 591/s 211h 130
URG240T6N• 40 33 38 40.000 75 0.64 43 36 605/4 20 3x4 50/56s/a 113h 571h 231h 137
URG240S6N- 40 33 38 40,0001 69 0.58 43 36 515fa 22 3x4 41/479A 11ah 495/a 255/2 149
URG15OT6N• 50 42 47 34,000 75 0.63 37 31 59% 20 3x4 50/56s/e 11a14 58 231h 153
URG250T6N• 50 42 48 4a,ODO 81 0.63 43 36 1 603ha 1 22 3x4 49zh157 1 113/, 585h5 255/2 160
URG25OL6N 48 90 47 40,000 77 0.63 43 36 1 51s/a 24 3x4 405/a 1 1131, 493/a 271/r 174
URG250S6N• 1 50 42 47 50,000 75 0.63 54 45 1 5911s 22 1 4 1 497h/57 1 1134 5821% 255/2 169
Model Nominal Recovery at A 8 C D E F G Approx.
Number Capacity DOE 50"C Him- Floor Jacket Vent Floor Floor Floor Depth Shipping
Rated First to Dia. Size to to to Weight
Storage Nat. Hour uniform Not. Flue T&P Gas Water
Volume kW Rating Energy Liters/ Conn. Conn. Conn. Conn.
Liters (Liters) Input (Liters) Factor Hour mm. mm. mm. mm. MM. mm. mm. kg.
URG13OT6N• 114 110 7.9 174 0.54 110 1502 406 76002 1264/1432 330 1461 495 51
URG230T6N• 114 110 9.4 227 0.60 129 1521 457 76x102 1267/1432 298 1448 546 54
URG140T6N• 151 144 10.0 243 0.59 139 1543 457 76x102 1308/1511 330 1502 546 59
URG24OT6N• 151 144 11.7 284 0.64 163 1530 508 76x102 1270/1438 298 1461 597 62
URG240S6* 151 1 144 11.7 262 0.58 163 13i1 559 76x102 1041/1200 298 1248 648 68
URG150T6N• 189 178 10.0 284 0.63 139 1514 Stiff 76x102 1270/1;i 2 330 1473 597 69
URG25OT6N• 189 182 11.7 307 0.63 163 1 1529 559 76x102 11267/1448 298 1 1481 648 73
URG250L6N 182 178 11.7 292 0.63 163 1311 610 76x102 1032 298 1254 699 79
URG25OS6N• 1B9 178 143 284 0.63 2D4 1511 559 102 11267/14481 298 1 1478 1 648 1 77
Available in Natural Gas only. Fc
For 10 year models,change suffix from"6"to"10".
' Based on manufacturers rated recovery efficiency.
•Models feature opfional top T&P location and must be specified when ordering.
Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings.
NRG130T,URG140T,&URG150T available with top T&P location ONLY)
® a
G
A
F •Optional T&P
o• Location Dimension
"D"dimension listed
as side/top.
E o
General: o
Meets NAECA Requirements.
All gas water heaters are certified at 300 PSI test pressure(2068 kPa)end 150 PSI working pressure(1034 kPa).All water connections are 314"NPT III 9mm)
on B"(203mm)centers.All gas connections are 12'(13mm).All models design-certified by CSA International(formerly AGA/CGA),to meet ANSI standard
Z21.10.1 and peak performance rated.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Suitable for Water(Potable)Heating and Space Heating.Toxic chemicals,such as those used for boiler treatment,shall NEVER be introduced Into this
system.This unit may NEVER be connected to any existing heating system or component(s)previously used with a non-potable water heating appliance.
4M
BRADFORD WHITE'
WATER HEAT E PS
Ambler,PA
For U.S.and Canada field service,contact your professional installer or local Bradford White sales representative.
Sales 800-523.2931•Fax 215-641-1670/Technical Support 800-334.3393•Fax 269.795.1089•Warranty 8OD-531-2111•Fax 269-795-1089
ov International:Telephone 215-641.9400"Telefax215.641-9750/www.bradfordwhitecom
BRADFORD WHITE- Sales/Technical Support 866-690-Ml/905.203.06OD•Fax 905-MOW6/www.bradfordwhite.com
.ATEP MEATE PS
Built to be the Be
0201 S.Bradford White Corporation.All rights reserved.
1113-B-0118 Printed in U.S.A.