PMT18-00960
City of Menifee Permit No.: PMT18-00960 29714 HAUN RD. �CCEL/ MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0311512018 PERMIT Site Address: 30584 GREEN VISTA DR, MENIFEE, CA Parcel Number: 358-671-015 92584 Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR SYSTEM, 9 PANELS, 9 MICROINVERTERS, 2.880 KW Work: DAKOTA TR 32025 LOT 112 Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET, STE 100 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone: 3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA33172 Fee Description 99C Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Pennil_Tempiate.rpt Page 1 of 1 BUILDING & SAFETY • APPLICATION Y Menifee DATE 02/28/2018 PERMIT/PLAN CHECK NUMBER °RMT4� TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL []MULTI-FAMILY ❑MOBILEHOME POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION []ALTERATION ❑DEMOLITION [Z]ELECTRICAL ❑MECIfMenifee ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES Building Dept. DESCRIPTION OF WORK INSTALL 2.880kW ROOF MOUNTED PV SYSTEM ryp / PROJECTADDRESS 30584 GREEN VISTA DRIVE, MENI FEE,CA Received Q V ASSESSOR'S PARCEL NUMBER 358-671-015 LOT 112 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES ✓❑NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $7,626.00 SQ FT L SO FT APPLICANT'S SIGNATURE DATE 02/28/2018 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE ^! PAID AMOUNT O AMOUNT O O CASH O CHECK# CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0CASH 0 CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM S1ZE 12.880KW I LOCATIONS INDICATED BY THE ILLUSTRATION. OD MULE 9 PCS. LG I LG320EIK-A5(320W) BUYER: - '- INVERTER 1 9 PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE I CONC.TILE DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MINNOW MOD OTY 4 5 NA NA BUYER: TILT I III- 1 18° 1 NA' NA' City AWBnifAH '! AZIMUTH 165° 255° NA' NA' �7 Building Dept, «- MAR 0 2 2018 Received 2'-I' 16'-9'ARRAY ) r a a e a h N M_ �D NEMA 3R JUNCTION BOX �? (1'OUTSIDE ARRAY) + u+ PV AC DISCONNECT EXTERIOR-GARAGE L'Approvai UTILITY METER a Q /Mi MAIN SERVICE PANEL I G A (VERIFIED BY BUILDER) 5'-6' PLANe A AC COMBINER BOX —i ^ I'R D E f th se p!a an violat NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF nd Inalc Oft PLAN 4 ELEVATION C-LEFT-ENH REAR/LIV ORIENTATION 2 LOT#112 ORIGINAL BY:KIM ABCOUWER DATEA8.02.27 DAKOTA AT WOODSIDE HOMES: 11870 PIERCE STREET,SUITE#100 REVIEWED BY:BRI MORRIS I DATE:18.02.28 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namasGib some DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 30584 GREEN VISTA DRIVE MENIFEE fi70T VSui70 Circle Suite PLOT PLAN 1/16'=1'-0' der. O8 0007 SYSTEM LAYOUT .CA Boulder. 303.447 70.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 9 1 LG LG320EIK-A5(320W) ACPV MODULE W/ INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 2 1 TBD TBD PV ROOF JUNCTION BOX.NEMA 3R SOLAR 3 1 CUTLER-HAMMER D0221URB PV AC DISCONNECT.NEMA 3R.24OV.30A SOLAR 4 I ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 I ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 6 I ENPHASE TBD PV BREAKER,I X 20A-2P,I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL.200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER.IPH.120/24OV.200A BLDR.ELEC. 10 1 Teo I TBD I GROUNDING ELECTRODE.UFER I BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 38 BUS RATING AMPS 200 TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TOELTA) Timm-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD, PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 1.17A x 901OD51- 10.53A OF CMRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(DO 320 19.53A X 1.25= 13.16A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED MESSER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE /RANGE AC MODULE SPEC VOLTS(AC) 240/ZII-264 NOMINAL OUTPUT CURRENT(AC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC ULI741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC OTY 9 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC'MOD.OTY Be) AMPS(AC) 10.53 AC MODULE QUANTITY,TOTAL MOD.OTY T OTY 9 TOTAL SYSTEM OUTPUT IHAXTs I (IAC•MOD.OTY T) AMPS(AC) 1 I0.53 CONDUCTOR SIZING CALCULATIONS D CONDITION OF USE(COU): (AMPACITY-TEMP.DERATE •FILL DERATE)vs.REDID(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REO'D,(IMAX- 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REDID OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COO 30 0.76 1.0 22.80 10.53 TERM 25 25 13.16 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 20 CONDUCTOR SCHEDULE KEY 1CONDUCTORS MAIL TYPE LOCATION TRADE q I-#12 ENPHASE 0 CABLE.1-#6G,FREE AIR CU OL3003,DG CABLE ARRAY SOLAR 9 B 1 3-#10`,I-#10 EGL I CU I NM-B(ROMEX) I INTERIOR I SOLAR O C 1 3-#10,I-#IO EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR M 'NEUTRAL CAPPED AND NOT USED '.IFEE Cl) © 'DSAFETY MES ; ✓AL © 20A2220A/2P shallnolbe onsln I 1 1 If any prov' ions( ROOF EXTERIOR-GARAGE This set ol appro ELECTRICAL DIAGRAM 2.88OKW LOT# 112 ORIGINAL BY:KIM ABCOUWER I DATE:18.02.27 WOODSIDE HOMES: DAKOTA AT REVIEWED BY:BRI MORRIS I DATE:18.02.28 11870 PIERCE STREET.SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY I DATE I DESCRIPTION •� na SOLAR DWG TITLE: PAGE#: SCALE. SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 30584 GREEN VISTA DRIVE der, P O8 PLOT PLAN 2 NTS MENIFEE.CA Boulder,C080301 ELECTRICAL 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ID ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10% =�� MEN BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 1Yi1. 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. r to be a I ermit fo z federa,state c Plans in ist be k, ORIGINAL BY:KIM ABCOUWER DATEf8.02.27 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:BRI MORRIS DATEf8.02.28 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION b namaste 30(AS DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 30584 GREEN VISTA DRIVE Suite 700 PLOT PLAN 3 NTS MENIFEE.CA Boulder,CO 80301 NOTES 344 03. 7.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BO% 0' OUTSIDE ARRAY) PV AC.DISCONNECT EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR 'G7J D ATE PV POWER SOURCE — AC SPECS it AC OPERATING VOLTAGE: 240 V PHOTOVOLTAIC SYSTEM EQUIPPE WITH RAPID SHUTDOWN e AC OPERATING CURRENT: 10.53A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:HIM ABCOUWER I DATEi8.02.27 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:BRI MORRIS DATE18.02.28 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION sbd tl I.W eouv DWG TITLE: PAGEJ11SCALE; SITE LOCATION: 6707VOnr esterCircle INDIVIDUAL 30584 GREEN VISTA DRIVE Suite700 PLOT PLAN 4TS MENIFEE,CA Boulder,CO 80301 PLACARDS 303.447.0300