Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-00953
City of Menifee Permit No.: PMT18-00953 29714 HAUN RD. �ACCEL/�. MENIFEE, CA 92586 Type: Residential Electrical ae. MENIFEE Date Issued: 0311512018 PERMIT Site Address: 24709 COLDWATER CANYON TR, Parcel Number: 358-671-012 MENIFEE,CA 92584 Construction Cost: $6,779.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR SYSTEM, 8 PANELS,8 MICROINVERTERS,2.560 KW Work: DAKOTA TR 32025 LOT 109 Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET,STE 100 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI,CA 33172 Fee Description Gil( Amount t5[ Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_elpg_Permit Template.rpt Page 1 of 1 availa a � • a • r- ;s ..'Menifee DATE, 02/28/2018 PERMIT/PLAN CHECK NUMBER PMftT027M— TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [-]SIGN SUBTYPE: ❑ADDITION []ALTERATION ❑DEMOLITION ❑✓ ELECTRICAL ❑MECHAf�J�{�gL [—]NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES CItyOMenlfee DESCRIPTION OF WORK INSTALL 2.560kW ROOF MOUNTED PV SYSTEM Y PROJECT ADDRESS 24709 COLDWATER CANYON, MEN[FEE, CA Rmcevis ASSESSOR'S PARCEL NUMBER 358-671-012 LOT 109 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN.MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES ✓❑NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $6,779.00 SO FT L SO FT APPLICANT'S SIGNATURES DATE 02/28/2018 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREENINVOICE SMIP AMOUNT W PAID AMOUNT , • O CASH O CHECK q O CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0 CHECK N OCREDITCARD VISA/Mc OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER U YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULE BEINSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTA THE SYSTEM SIZE 2.560 XW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8PCS. LG I LG320EIK-A5(320W) BUYER: INVERTER 8PCS. ENPHASE I 106PLUS-72-ACM-US ROOF TYPE CONIC. TILE DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MODOTY 8 Nq NA NA BUYER: TILT 23' NA° NA- NA' AZIMUTH 180- NA' NA- NA' DATE: City of Menifee Building Dept. MAR 0 2 2018 Received r 1 i I � I i I 9'-2' 18'-4'ARRAY I 1 t I I _ I I = I I NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) -- 0 I I CI ry I PV AC DISCONNECT ( 13 IL[ EXTERIOR-GARAGE i UTILITY METER 8 P AN MAIN SERVICE PANEL — (VERIFIED BY BUILDER) — AC COMBINER BOX —-i VIE 'Alprova ap roval recuMoi jot site al NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2 ELEVATION C LEFT ORIENTATION 3 LOT#109 ORIGINAL BY: JIM PARKS DATE: 18.02.27 DAKOTA AT WOODSIDE HOMES: 1187E PIERCE STREET.SUITE#100 REVIEWED BY: DAN BOWLING I DATE: 18.02.28 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION b namasbe SMA. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VSufte7 0 Circle INDIVIDUAL 24709 COLDWATER CANYON TRAIL der, O8 PLOT PLAN I I/16`= I'-0' MENIFEE.CA Boulder,7.030E t SYSTEM LAYOUT 303.947.030E ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 B 1 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 TBD TBD PV ROOF JUNCTION BOX.NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR 4 1 ENPHASE IQ ENVOY ENV-IOAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 20A-2P,I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL.200A BUS BLDR. ELEC. 9 1 TBD TBD UTILITY METER, IPH,120/24OV.200A BLDR. ELEC. 10 1 TBD I TBD I GROUNDING ELECTRODE,UFER I BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% -C 38 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN •C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 ALLOWED PV PER NEC AMPS 40 TEMP.DELTA LOW(TDELTA) TMIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 20 MOD.MANUFACTURER AC MODULE SPEC LG. INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC -G320EIK-A5(320W) 1.17A x B(MODS)- 9.36A OF CMENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 9.36A x 1.25= II.70A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED MR ER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/ZII-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 I IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY Bc OTY 8 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC•MOD.PTY Bc) AMPS(AC) 9.36 AC MODULE QUANTITY,TOTAL MOD.0TY T 0TY 8 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD.OTY T) AMPS(AC) 9.36 CONDUCTOR SIZING CALCULATIONS n CONDITION OF USE(COU): (AMPACITY •TEMP.DERATE •FILL DERATE)n.REO'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REO'D,(IMAX• 1.25) KEY SIZE I CU/AL INSULATION CAI-C. AMPACITY W/O TEMP. FILL RESULT REG'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #IZ CU THWN-2 COU 30 TERM 25 0.76 1.0 25.80 11i70 20 MENIF EE B 710 CU NM-B COU 40 0.91 1.0 36.40 9.36 TERM 35 35 111.70 20 iG AND SA C #10 CU I NM-B COU 40 0.91 1.0 36.40 1 9.36 TERM 35 35 1 11.70 20 ?PROV kL CONDUCTOR SCHEDULE KEY 1CONDUCTORS CU/AL TYPE LOCATION TRADE q I-#12 ENPHASE 0 CABLE, I-#bG,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR ED BY B 3-#10•. I-#10 EGL CU NM-B(ROMEX) INTERIOR SOLAR 9 L 3-#10, -010 EGC CU NM-B(ROMEX) INTERIOR SOLAR 'NEUTRAL CAPPED AND NOT USED M -- eseplans all nt y violation tany n ordinano . Tha 4 f 5A/2P c mpleu0n. O 7 O © � 20A/2 2 20A/2P G G G A B C C — 10 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.560KW LOT#109 ORIGINAL BY: JIM PARKS I DATE: 18.02.27 DAKOTA AT WOODSIDE HOMES: REVIEWED BY: DAN BOWLING DATE: 18.02.28 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namaste SOIAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 24709 COLDWATER CANYON Suke700 PLOT PLAN 2 NTS MMIEEE,CA Boulder,CO$0301 ELECTRICAL I 303.AG7.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 11)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AM LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690,12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS, 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IO MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF 2)EQUIPMENT GROUNDINACE AND G COND BE UCTORS WILL BEAGED IN A R SIZED IN ACC ACCORDANCE WITH NEC TABLE 250.1221 •TY DEPARTME T 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 1 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE ERING MINIMUM HEIGHT t. DAl 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. COnstrued to be a permit r,Dr an 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. 11510ns Of the federal,state rO1tlI of approved plans must be ept on I ORIGINAL BY: JIM PARKS DATE:18.02.27 DAKOTA AT WOODSIDE HOMES: REVIEWED BY: DAN BOWLING I DATE:18.02.28 11870 PIERCE STREET.SUITE#100 AUDIE MURPHY RIVERSIDE.CA 92505 REV.# BY DATE DESCRIPTION namasCe f OIAR DWG TITLE: PAGE*: I SCALE: SITE LOCATION: 6707 Winchester Cirda INDIVIDUAL 2470E COLDWATER CANYON der, 700 O8 PLOT PLAN 3 NTS WBAIEEE.CA BnNBe4 C NOTES 303.447.03M300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.36A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: JIM PARKS DATE: 18.02.27 DAKOTA AT WOODSIDE HOMES: REVIEWED BY: DAN BOWLING DATE: 18.02.28 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namastAR SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 8707 Vder Circe ufte 7O INDIVIDUAL 2470E COLDWATER CANYON der.CO PLOT PLAN 4 NTS RBWIEEE.CA Baultler, O 80307 PLACARDS 1 1 303.447.0300