PMT18-00628 City of Menifee Permit No.: PMT18-00628 29714 HAUN RD. <-�CCF—L� MENIFEE,CA 92586 Type: Residential Electrical '"""'" MENIFEE Date Issued: 03/16I2018 PERMIT Site Address: 29053 BAYLEAF CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,420.64 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 10 MODULES, 10 MICROINVERTERS,3.20kW LOT 54 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number. 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description gty Amount fSl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDIN & SAFETY PERMIT/PLAN CHECK APPLICATION t- Menifee DATE:2/5/2018 PERMIT/PLAN CHECK NUMBER (gr �(09S TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- 3.20 kW, 10 pcs, Master Solar Permit No: PMT 17-00129 Plan No: 2686 PROJECTADDRESS 29053 Bayleaf Cir ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT 54 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANTNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO BUSINESS NAME Lennar Homes of California ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8,420,64 SQ FT LSQ FT APPLICANT'S SIGNATURE DATE 2/5/2018 _CITYST DEPARTMENT DISTRIBUTION ACCEPTED BYE T +ice/ �p.� CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE {/`� PERMIT FEE 5014 U� SMIP Q. GREEN I PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZEDLE17ER O YES O NO City of Menifee Building&Safety Department 29714 HDun Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.200 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS.1 LG I LG320EIK-A5(320W) BUYER: INVERTER 1 IO PCS.1 ENPHASE I 106PLUS-72-ACM-US _ ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION CITY OF MENIF EE ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 �� MOD OTY 10 NA NA NA BUYER: �Q h TILT 23' NA' I NA' NA, AZIMUTH 1 257° 1 NA' I NA- NA' City OI Menrfe+ DATE: Building Dept. FEB 1 " 2018 REVIEWED A Received 3' II'-I' App rovaloftheseplans shda approval of,any violatim of any regulations and ordkm is. Thli jobsite until compktlom rz �a r P LL 00 1 SOLADECK WIRE TRANSITION BO% (UNDER ARRAY) O PV AC DISCONNECT EXTERIOR-GARAGE _ UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BO% NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2628 ELEVATION B-LEFT ORIENTATION 3 LOT#54 IN LENNAR: ORIGINAL BY:DAN BOWLING DATE:18.01.09 HERITAGE HEIGHTS 980 MONTECITO DRIVE.#302 REVIEWED BY:ARTHUR HICKS JDATE:18.09.10 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namast� soLAe DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Wnchesler Cirde INDIVIDUAL 29053 BAYLEAF CIRCLE Sub 700 PLOT PLAN 1 1/16'=Y-0' MENIFEE,CA Bodder,GO 80301 SYSTEM LAYOUT 1 303.447,0300 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES nBLDR. DE 1 10 LG LG320EIK-AS(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLU5-72-ACM- R 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3RR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV,30AR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V R 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX R DE 6 1 ENPHASE TBD PV BREAKER,I X 20A-2P.I X 5A-2PR TY 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P.RATING MAY VARYAR 8 I TBD TBD SERVICE PANEL,200A BUS . ELEC. 9 1 TBD TBD UTILITY METER.[PH.120/24OV,200A . ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,UFER . ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 ALLOWED PV PER NEC AMPS 40 c oll&A TEMP.DELTA LOW(TELLTA) THIN-TTEST 'C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: Allonsof MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) LI7A X ID(MODS)= 1I.70A OF CURRENT 0 ppm MOD.POWER STC(P) AC MODULE SPEC WATTS(m) 320 II.7Da X L25= 1 611 PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 2BARP 2 SPACE PV BACKFEEO BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC I VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/ IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 - AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC GTY 10 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC-MOD.QTY 80 AMPS(AC) 11.70 AC MODULE QUANTITY,TOTAL MOD.OTY T OTY 10 TOTAL SYSTEM OUTPUT IMAXTS (IAC-MOD.QTY T) AMPS(AC) 11.70 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COLD: (AMPACITY- TEMP.DERATE-FILL DERATE)vs.REO'D(TMAX) 2)TERMINALS(TERM AMPACITY AT TERMINALS.VS.REG'D,([MAX• 1.25) KEY S12E I CU/AL INSULATION CALL AMPACITY W/O TEMP. FILL RESULT REG'D 920 TYPE DERATES DERATE DERATE (A) (A) A %12CUTHWN-2 COU 30 .76 1.0 22.80 11.70 TERM 25 25 14.63 B NM-B COU 40 .91 .036.40 11.70 TERM 35 35 14.63 C NM COU 40 .91 L0 36.40 11.70 TERM 35 35 14.63 CONDUCTOR SCHEDULE ti KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENPHASE Q CABLE.I-#6G,FREE AIR Cu UL3003,OG CABLE ARRAY SOLAR B 3-#10'.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10,1-#10 EGC CU NM-8(ROMEX) INTERIOR SO'NEUTRAL CAPPED AND NOT USED4Q3O 5A/2P 06 zoazP G G� R EXTERIOR- ROOF GARAGE ELECTRICAL DIAGRAM 3.2OOKW LOT#54 ORIGINAL BY:DAN BOWLING DATE:18.01.09 HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE.#302 REVIEWED BY:ARTHUR HICKS DATE: 18.09.10 CORONA,CA 92879 REV.# BY DATE DESCRIPTION �Sncimasbd SOLAR DWG TITLE: PAGE tt: SCALE: SITE LOCATION: 6707 Vdrrhester Circle INDIVIDUAL 29053 BAYLEAF CIRCLE Su8e700 PLOT PLAN 2 NTS MENIFEE,CA Boulder,CO 80301 ELECTRICAL 303AA7.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. �� 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(k)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(10 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SMALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. , 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. Q BIRDSTOP TO BE SPECIFIED.BY ROOFER PRIOR TO INSTALLATION. be a pei `ederal, fans mu: ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE-2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO.PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT ip. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRINGIRACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SMALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110-26.. ORIGINAL BY:DAN BOWLING DATE:I .01.09 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATE:18.09.10 980 MONTECITO DRIVE,4302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION masbA Six seecR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VvSnUrester Circle INDIVIDUAL 29053 BAYLEAF CIRCLE Suite 700 PLOT PLAN 3 NTS MENIFEE.CA Boulder,CO 8=1 NOTES 303.447.03DD CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ! I ARE LOCATED AS SHOWN. or an r city kept on the SOIADEC(WIRE TRANSITION BO% DINER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING DATE:18.01.09 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATE:18.09-10 CO NA,CA I92 DRIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION smast6 ,na sC DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL MENIF E.CA F CIRCLE SURder. O8 700 PLOT PLAN 4 NTB MENIFEE.CA BODIDBC C0800 PLACARDS 003,AgT.0300