Loading...
PMT18-00627 City of Menifee Permit No.: PMT18-00627 29714 HAUN RD. �1-�CCELJ-> MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 03116f2018 PERMIT Site Address: 29039 BAYLEAF CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES,7 MICROINVERTERS,2.24kW LOT 53 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qty. Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee- Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK Menifee DATE:2/5/2018 PERMIT/PLAN CHECK NUMBER ' - DOLv TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- 2.24 kW, 7 pcs, Master Solar Permit No: PMT 17-00129 Plan No: 1678 PROJECTADDRESS 29039 Bayleaf Cir ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT 53 TRACT31582 OWNERNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com ' CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME Lennar Homes of California ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 5,613.76 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 2/5/2018 DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE - PERMITFEE C 3 L 0 SMIP — GREEN PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityqfmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM I OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.24OKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 7 PCS.1 LG I LG320EIK-A5(320W) BUYER: INVERTER 1 7 PCS.1 ENPHASE I I06PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION - MOD OTY ARRAY#I ARRAY AA#2 ARRAY A#3 ARRAY AA#4 BUYER: ME IFE! TILT 23' NA' NA' NA' AZIMUTH 257- NA' NA. IN DATE: BUILDINGD City of menifee PLAN APPR VAl Building Dept. FEB 1 h 20V REVIEWED EY4 Received 'Approval of these ph ns IsM 3' 5._6* approval of,any viola ion of a regulations and ordin nces. 1 jobsite until completi n. i u >z ai .� ► c a QJ Nj SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV DISCONNECT EXTEE RIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL Tsp (VERIFIED BY BUILDER) b AC COMBINER BOX , 60 9 4111111111111111111 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1678 ELEVATION C RIGHT ORIENTATION 3-RIGHT LOT#53 IV ORIGINAL BY:DAN BOWLING DATE: 18.01.09 HERITAGE HEIGHTS LENNAR: 980 MOMECITO DRIVE.#302 REVIEWED BY:ARTHUR HICKS DATE: IB.01.10 CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vniarric3sr6 30LA� DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 Wrlcheeler Circle INDIVIDUAL 29039 BAYLEAF CIRCLE Su8e 700 PLOT PLAN 1 1/16'=1'-0' MENIFEE.CA 9oulder,CO WWI SYSTEM LAYOUT 303.447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES TRADE 1 7 1 LG LG320EIK-A5(320W) ACPV MODULE W/ INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF.JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,24OV.30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER, I X 20A-2P,I X SA-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.RATING MAY VARY SOLAR n 8 1 TED TBD SERVICE PANEL.200A BUS BLDR. ELEC. Y 9 1 TBD TBD UTILITY METER, IPH, 120/24OV,200A BLDR.ELEC. le 1 TBD TBD GROUNDING ELECTRODE.LIFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATION ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS I 40 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 1 20 MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: a Contra MOD, PART NUMBER AC MODULE SPEC LG320EIK-A5(32OW) 1.17A X 7(Ma0S)° E,19A aF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(aa) 320 8.19A X 1.25= 10.2AA It A shins e PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEEa BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 ( s NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT OAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC U1_1741 /IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BC OTY 7 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC-MOD.GTY 80 AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD.QTY T OTY 7 TOTAL SYSTEM OUTPUT IMAXTS (JAC'M00. OTY T) AMPS(AC) 8.19 ` CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COLD: (AMPACITY`TEMP.BERATE°FILL BERATE)VS.REO'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS.REO'D,(IMAX-1.25) KEY SIZE CU/AL INSULATION CALL' AMPACITY W/O TEMP. FILL RESULT REQ'D BCD TYPE BERATES DEBATE BERATE (A) (A) USED(A) A #1 CCU THWN-2 COU 30 .76 L0 22.80 8.19 TERM 25 25 10.24, 20 B #10 CU NM-B COU 40 .91 1.0 36.40 19 TERM 35 35 10.24 20 C #10 CU NM-B COU 40 .91 L0 36.40 8.19 TERM 35 35 10.24 20 CONDUCTOR SCHEDULE AM KEY CONDUCTORS CU/AL TYPELOCATION TRADE I_012ENPHASE Q CABLE,F#6G.FREE AIR CU UL3003,DG CABLE ARRAY SOLAR _ B 3-#10',I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10,1-#10 EGL CU NM-B(ROMEX) INTERIOR SOLAR i O 'NEUTRAL CAPPED AND NOT USED B 4 e O SA/2P O O © 2OA 2F 2 20A/2P _ 'N G G G� A B C I I ROOF EXTERIOR GARAGE ELECTRICAL DIAGRAM 2.24OKW LOT#53 ORIGINAL BY:DAN BOWLING DATE: LENNAR: 18.01.09 HERITAGE HEIGHTS REVIEWED BY:ARTHUR HICKS DATE: 1B.01.I0 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY I DATE I DESCRIPTION namast8 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VAnchester Circle INDIVIDUAL 29039 BAYLEAF CIRCLE Suite 700 PLOT PLAN 2 NTS MENIFEE,CA Boulder,CO 8B307 ELECTRICAL 303.4A7.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED ARDUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% 11)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE I APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO.BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. fe JorA di ipl fnNNtl ELECTRICAL NOTES: GENERAL- 0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 5)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT e. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DAN BOWLING DATE:18.01.09 HERITAGE HEIGHTS 980 MO: REVIEWED BY:ARTHUR HICKS DATE:18.01.10 CO NA,CA I92 DRIVE,#302 -' CORONA,GA 92879 REV.# BY DATE DESCRIPTION namastd S.L.l DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 W(nrhes rGlcle INDIVIDUAL 29039 BAYLEAF CIRCLE Solte 700 PLOT PLAN 3 NTS BoWtler,CO 80301 NOTES MENIFEE.CA =mTMKKI CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS T ARE LOCATED AS SHOWN. 1 r,'dr �l lr city ept on ` SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 6 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8.19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING I DATE:18.01.09 LENNAR: HERITAGE HEIGHTS REVIEWED BY: HICKS DATE: IB.OI.IO 980 MONTECITO DRIVE,#302 CORONA.CA 92879 REV.# BY DATE DESCRIPTION Vnamasb6 SMAY DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 Winchester Circle INDIVIDUAL 29039 BAYLEAF CIRCLE Suhe700 PLOT PLAN 4 NTS MENIFEE.CA Boulder,CO B0301 PLACARDS 303.447.0300