Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT18-00626
City of Menifee Permit No.: PMT18-00626 29714 HAUN RD. Type: Residential Electrical <ACCEL/7 MENIFEE,CA 92586 " MENIFEE Date Issued: 03/16/2018 PERMIT Site Address: 29025 BAYLEAF CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 7 MICROINVERTERS,2.24kW LOT 52 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description gtv Amount ISI Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing bulliding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK A. • • ..y "Wenifee DATE:2/5/2018 PERMIT/PLAN CHECK NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- 2.24 kW, 7 pcs, Master Solar Permit No: PMT 17-00129 Plan No: 1782 PROJECTADDRESS 29025 Bayleaf Cir Zip 92584 ASSESSOR'S PARCEL NUMBER LOT 52 TRACF31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES O NO BUSINESS NAME Lennar Homes of California ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 5,613,76 SQFT LSQFT APPLICANT'S SIGNATURE DATE 2/5/2018 DEPARTMENT DISTRIBUTION ACCEPTED BY: 0 t/J_ CITY OF MENIFEE BUSINESS LICENSE NUMBER /r(/)1!(� BUILDING PLANNING ENGINEERING FIRE PERMITFEE �, �V SMIP GREEN I PLAN CHECK FEE INVOICETOTAL OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES 0 NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityoftenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. I MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.24OKW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 7 PCS.1 LG I LG320EIK-A5(32OW) BUYER: INVERTER 1 7 PCS.1 ENPHASE I 105PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 CITY OF M NII MOD OTY 7 NA NA NA BUYER: DIN G ANI TILT 23• NA' NA' NA' tSUIL AZIMUTH 257• NA' NA" Cit NA' DATE: y of Nlenifee R01 Building Dept. FEB I ` 201P REVIEWS Received 'Approvalofth eplee 3 5'-e• approval of,any o* regulations and rdirun " jobsito until cal 113101 >z �g ±e LL H: SOLADECK WIRE TRANSITION BOX CINDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX v NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1782 ELEVATION B LEFT ORIENTATION 3 LOT#52 ORIGINAL BY:DAN BOWLING DATE:18.01.09 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATE: 18.01.10 CORONNA.A.C CA 980 DRIVE.#302 REV.# BY DATE DESCRIPTION A 92879 namasCi§ DWG TITLE: PAGE#: SCALE: rCiml SITE 6707 VSufte ter Ci¢le INDIVIDUAL 29025 E.CA F CIRCLE SUIIe 700 O8 PLOT PLAN /Ib'=I'-0' MENIFEE.CA Ba303.4 CO3DO SYSTEM LAYOUT �,gg7.08pp ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES I TRADE I 7 LG LG320EIK-A5(320W) ALPV MODULE W/ INTEGRATED ENPHASE I06PLU5-72-ACM-US MICROINVER7ER SOLAR 2 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,2LOV,50A SOLAR L ENPHASE IQ ENVOY ENV-IOAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER.I X 20A-2P.I X SA-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLARLr 8 1 TBD TBD SERVICE PANEL.200A BUS BLOB. ELEC.91 TBD TBD UTILITY METER.IPH.120/24OV,200A BLDR. ELEC. 10 I TBD TBD GROUNDING ELECTRODE,UFER BLDR. ELEC.AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATI ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMaR TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 1 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 MAIN DISCONNECT I AMPS 1 200 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC I AMPS 1 40 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED I AMPS j 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) I.17A x](MOOS)= 8.19A OF CURRENT any MOD. POWER STC(P) AC MODULE SPEC WATTS(CC) 320 8.19A x 1.25= 10.24A j PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20Al2P 2 SPACE PV SACKFEEO BREAKER P jp MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59-3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.QTY 8C OTY 7 BRANCH CIRCUIT OUTPUT, IM LXSC (LAC-MOD.QTY 8C) AMPS(AC) 8.19 1 AC MODULE QUANTITY,TOTAL MOD. QTY T QTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD.QTY T) AMPS(AC) 1 8.19 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COU): EAMPACITY MP.DERATE•FILL DEBATE)vs.REOT(IMAX) 2)TERMINALS(TERM): ERMINALS.v5.REQ'0,(IMAX - 1.25) KEY SIZE CU/AL INSULATION CALL. TEMP. FILL RESULT REQD OCD TYPE DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 16 10 22.80 8.19 TERM 25 10.24 20 B #10CUNM-B LOU 911036.40 5.19 TERM 35 10.24 20 C #10 LU NM-B COU .911036.40 0.19 TERM 35 10.24 20 CONDUCTOR SCHEDULE 0 KEY CONDUCTORS CU/AL TYPE .LOCATION TRADE A I-4 12 ENPHASE Q CABLE,1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR O — B 1 3-910•.1-#10 EGC CU NM-B(ROMEX) INTERIOR I SOLAR C 3-#10.1-*10 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR O'NEUTRAL CAPPED AND NOT USED B 4 e O3 O SA/2P O O © 20A/2P 20A/2P L __— AN, G G A B C C = 10 ROOF I ERTEnf6R� GARAGE ELECTRICAL DIAGRAM 2.240KW LOT#52 ORIGINAL BY:DAN BOWLING DATE:18.01. LENNAR: 09 HERITAGE HEIGHTS REVIEWED BY:ARTHUR HICKS I DATE: 18.01.10 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION �Sniannast;d SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 6707 VAndlester Circle INDIVIDUAL 29025 BAYLEAF CIRCLE Suite 700 PLOT PLAN 2 NTS MENIFEE,CA Boulder,C080301 ELECTRICAL 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV RDOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. _ 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. AP RTM 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH Q1 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS.TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF S. f 10 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. �I 14)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. :d t be I PIS thi Cede* ved Otmfou ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT Al ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SWILL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE.OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- (9)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26, ORIGINAL BY:DAN BOWLING DATE:18.01.09 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATE:18.01-10 980 MONTECITO DRIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION tit musbob SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707V6n&.4er Clyde INDIVIDUAL 29025 SAYLEAF CIRCLE Suite 700 PLOT PLAN 3 NTS MENIFEE,CA Boulder,CO SM01 NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE T UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. wo oA I t or CRY kept on tla .43 XX SOLADECI(WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DAN BOWLING DATE:18.01.09 HERITAGE HEIGHTS LENNAR: REVIEWED BV:ARTHUR HICKS DATE:1 980 MONTECITO DRIVE,#3G2 8.01.10 CORONA,CA 92879 REV.# I BY DATE I DESCRIPTIONt. namasbd POLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6797 VArwhester Circe INDIVIDUAL 29025 BAYLEAF CIRCLE Suite 70D PLOT PLAN 4 NTS MENIFEE,CA BDulder,CO WWI PLACARDS 303.447.0300