Loading...
PMT18-00622 City of Menifee Permit No.: PMT18-00622 29714 HAUN RD. '/,CCEC? MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 3/1 612 01 8 PERMIT Site Address: 29036 BAYLEAF CIR, MENIFEE,CA Parcel Number: 92584 Construction Cost: $8,420.64 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 10 MODULES, 10 MICROINVERTERS,3.20kW LOT 48 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number. 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description QtV Amount($) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee- Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA Bldg_Permit_Template.rpt Page 1 of 1 SAFETYBUILDING & PERMIT/PLAN CHECK APPLICATION r�: .•=Menifee DATE:2/5/2018 PERMIT/PLAN CHECK NUMBER TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- 3.20 kW, 10 pcs, Master Solar Permit No: PMT 17-00129 Plan No: 2686 PROJECTADDRESS 29036 Bayleaf Cir ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT 48 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANTNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES O NO BUSINESS NAME Lennar Homes of California ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8,420.64 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 2/5/2018 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: O 1 PERMITFEE W SMIP GREEN PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 HDun Rd. Menifee, CA 92586 951-672-6777 www.cityofTIenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.200 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS.1 LG I LG320EIK-A5(320W) BUYER: -- INVERTER 1 10 PCS.1 ENPHASE I IGOPLUS-72-ACM-US `j j`�ENI EE ROOF TYPE TILE W7 COMPOSITE SHINGLE UNDER ARRAY DATE:SUB-ARRAY INFORMATION BU IDLI NG AN 8A ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 10 NA NA NA y�� BUYER: RO TILT 23' NA' NA' NA* City Of Menifee PLAN DATE: AZIMUTH 270• M. NA "A' Building Dept. FEB j�E 1 'I 20?8 REVIEWED B Received 'Approval of these plans Ad approval of,any violatioi i of on) s' regulations and ordlunc m Thl jobsite until completim i SOL �y aLL -= V r ADECK WIRE TRANSITION BOX (UNDER ARRAY) O PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 2628 ELEVATION A-RIGHT ORIENTATION LOT#0048 ORIGINAL BY:ANGELA BURKE DATE:09.20.17 HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE.#302 REVIEWED BY:ARTHUR HICKS I DATE:09.21.17 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast� SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 W,,c ster Circe INDIVIDUAL 29036 BAYLEAF CIRCLE Suite 700 PLOT PLAN I 1/16'=1'-0' MENIFEE.CA Boulder,CO 80301 SYSTEM LAYOUT 303.447.0300 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 10 1 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 1 RSTC/SOLADECK 0766-3115 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 I CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 4 I ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR Hy DE 5 I ENPHASE X-I0-AMI-240-B AC COMBINER BOX SOLAR 6 I ENPHASE TBD PV BREAKER.I X 2OA-2P.I X SA-21? SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P,RATING MAY VARY SOLAR 8 I TBD TBD SERVICE PANEL.200A BUS BLDR.ELEC. 9 I TBD TBD UTILITY METER, IPH, 120/24OV,200A BLDR.ELEC. 10 I TBD TBD GROUNDING ELECTRODE.UFER BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 200 TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN •C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TEEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 Ions d TEMP.DELTA LOW(TELLTA) THIN-TTSST •C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: two MOD. PART NUMBER AC MODULE SPEC LG320EIK-AS(320W) I.I7A x m(MODS)= IIJDA OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(130 320 1I.70A x 1.25• 14.63A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-tN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEEI547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY.BC' CITY 10 BRANCH CIRCUIT OUTPUT,IMAXBC (IAC-MOD.QTY SO AMPS(AC) 11.70 ` AC MODULE QUANTITY,TOTAL MOD.CITY T QTY 10 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD.OTY T) AMPS(AC) 11.70 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COU): (AMPACITV' TEMP. DEBATE`FILL DEBATE)v5.REQ'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REO'D,([MAX• 1.25) KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REQ'D BCD TYPE BERATES BERATE DEBATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 .76 1.0 22.80 11.70 TERM 25 25 14.63 20 B #10 CU NM-S LOU 40 .91 LO 36.40 IL70 TERM 35 35 14.63 20 C #10 CU NM-B COU 40 .91 L0 36.40 11.70 TERM 35 35 14.63 20 CONDUCTOR SCHEDULE KEY 1 CONDUCTORS 1 CU/AL 1 TYPE LOCATION 1 TRADE 9 A I-#12 ENPHASE G CABLE.1-#6G,FREE AIR CU UL3003.DG CABLE ARRAY SOLAR B 3-#10-.I-410 EGC CU NM-B(ROMEX) INTERIOR SOLAR O C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR 'NEUTRAL CAPPED AND NOT USED O 4 O3 0 !'2P 7O20A/2P R G ■ G G� A B C I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.20OKW LOT#004E ORIGINAL EY:ANGELA BURKE I DATE:09.20.17 HERITAGE HEIGHTS LENMAR: 980 REVIEWED BY:ARTHUR HICKS DATE:09.21.17 CORONNA,A.L CA A 92 DRIVE,#302 879 REV.# BY DATE DESCRIPTION I�Rmamast;d SOLAR OWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VVinoheeter Circa INDIVIDUAL 29036 BAYLEAF CIRCLE Suite 700 PLOT PLAN 2 NTS MENIFEE,GA BDuIOeT,CO 80301 ELECTRIC I 303.447.D3DO INSTALLATION NOTES: _ SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. RTM 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. '•I 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH({')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. - 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. ID 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. be a poi 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. federal,'. tans mu ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT l'. IB)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED-PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:ANGELA BURKE DATED9.20.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATED9.21.17 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namaste aaeAe DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707WNO h.ter Cimle INDIVIDUAL 29036 BAYLEAF CIRCLE Suite 700 PLOT PLAN 3 NTS MENIFEE,CA BoVder,CO S0301 NOTES 303.447A300 CAUTION: T POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. r,a n or city a kept on 04 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:ANGELA BURKE I DATE:09.20.17 LENNAR: HERITAGE HEIGHTS REVIEWED BY:ARTHUR HICKS DATE99.21.17 980 MONTECITO DRIVE,#302 CORONA,CA 92979 REV.# BY DATE DESCRIPTION tit mva masb6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 6707 VVIIIIcIvate,Circe INDIVIDUAL 29036 BAYLEAF CIRCLE Suite 700 PLOT PLAN 4 NTS MENIFEE.CA BouNer,CO W30T PLACARDS I 303.447A300