Loading...
PMT18-00618 City of Menifee Permit No.: PMT18-00618 29714 HAUN RD. <ACCELi%> MENIFEE, CA 9258E Type: Residential Electrical MENIFEE Date Issued: 03/16/2018 PERMIT Site Address: 29095 BAYLEAF CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,420.64 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 10 MODULES, 10 MICROINVERTERS,3.20kW LOT 56 Owner Contractor LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 SAMANTHA MAZELLA License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Qtv Amount 1$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE:2/5/2018 PERMIT/PLAN CHECK NUMBER 1" -Te s TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: C ADDITION O ALTERATION O DEMOLITION C ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit - 3.20 kW, 10 pcs, Master Solar Permit No: PMT 17-00129 Plan No: 2686 PROJECTADDRESS 29095 Bayleaf Cir ZIP 92584 ASSESSOR'S PARCEL NUMBER LOT 56 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME Lennar Homes of California ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-8173539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8,420.64 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 21512018 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE SMIP a� GREEN ( � PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE!# NOTARIZED LETTER O YES C. NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.200 KW LOCATIONS INDICATED BY THE ILLUSTRATION, MODULE 10 PCS.j LG I LG320EIK-A5(32OW) BUYER: INVERTER I 10 PCs. ENPHASE I IO6PLUS-72-AGM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION _ ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 10 NA NA NA a of Men'rfee BUYER: TILT 23° NA' NA' "A° Building Dept. 4--imm MOP AZIMUTH 270° NA• NA° NA• DATE: IGID 10 alop I 44 FEB 1 2Q'3 URJ0 J0 Imued a9e9P Received 55�x1 1N3 KZ SOLADEC N ag ns WIRE TRANSITION BOX V (UNDER ARRAY) AC DISCONNECT _ EXTERIOR-GARAGE UTILITY METER e RAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION A-LEFT ORIENTATION 3 LOT#56 LENNAR: ORIGINAL BY:T HAMMERBACHER DATE:IJ.I2.O4 HERITAGE HEIGHTS REVIEWED BV:KIM ABCOUWER DATE:17.12.05 CONA.CA I92 DRIVE.#302 CORONA,LA 92879 REV.# BY DATE I DESCRIPTION namasti§ SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4B I&r.BroadwayCO8Slreet INDIVIDUAL MENIF E.CA F CIR BO3D3.4C080804 PLOT PLAN 1 I/16'= I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES TRADE 1 10 1 LG LG320EIK-A5(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR, Z40V SOLAR 5 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR ' 6 1 ENPHASE TOD PV BREAKER,I X 20A-2P.I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. Jj. W�IS� 9 1 TBD TBD UTILITY METER,IPH,120724OV.200A BLDR.ELEC. 7�y 10 1 TBD TBD GROUNDING ELECTRODE,LIFER BLDR.ELEC. !mqA( Imp AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIO PIP01 ITEM NOTE/CALC UNIT DETAIL ITEM UNIT 1 PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HA TEMP.AMBIENT HIGH(THAX) ASHRAE 2% 'C 37 BUS RATING AMPS 1 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 1 40 TEMP,DELTA LOW MELTS) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5 MR) I.DA x l0(MOOS)= 11.70A OF NRRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 11.70A x 1.25- 14.63A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A ZOA/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(.AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT OAC) AC MODULE SPEC AMPS(AC) 1.I7 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/JEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC QTY 10 BRANCH CIRCUIT OUTPUT.IMAXEC (IAC•MOD.GTY BC) AMPS(AC) 11.70 AC MODULE QUANTITY,TOTAL MOD.QTY T OTY 10 TOTAL SYSTEM OUTPUT lmxTs (IAC•MOO.OTY T) AMPS(AC) IL70 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE`FILL DERATE)vs.REO'D OMAR) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REQ'D.(IMAX• 1.25) ZKEYCUIAL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD TYPE OERATES DERATE DEBATE (A) (A) USED(A) THWN-2 COU 30 .76 1.0 22.B0 11.70 TERM 25 25 14.63 20 NM-B COU 40 .91 1.0 36.40 11.70 TERM 35 35 14.63 20 NM-B COU 40 .91 1.0 36.40 11.70 TERM 35 35 14.63 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE q I-#12 ENPHASE G CABLE,146G.FREE AIR I CU UL3003,DG CABLE ARRAY SOLAR 9 B 1 3-#10•.170 EGC CU NM-B(ROMEX) I INTERIOR SOLAR C 1 3-#10, 1-#10 EGC CU NM-B(ROMEX) I INTERIOR I SOLAR O 'NEUTRAL CAPPED AND NOT USED B OSA12P I 7 O © ou o4rz t_r � N D ' G A B C C = 10 ROOF EXTEHIIXt-GAAAGE 1 ELECTRICAL DIAGRAM 3.200xW LOT#56 ORIGINAL BY:T HAMMERBACHER I DATE:17.12.04 HERITAGE HEIGHTS LENNAR: REVIEWED BY:KIM ABCOUWER I DATE:17.12.05 980 MONTECITO DRIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasw$ SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadxay Street INDIVIDUAL 29095 BAYLEAF CIR Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303,447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 'OO IdwoOl 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(")SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. DUE if pa B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. IpJo`'_ 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 14OIA A 1 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. ID 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE jei I mom APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. u 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.K•>t E an BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. .y fav NIF90 1N N A ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SMALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC7CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS.WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:T HAMMERBACHER I DATE17.12.04 HERITAGE HEIGHTS LENNAR:980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ABCOUWER I DATE17.12.05 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vncimast;6 DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Smadway SiI INDIVIDUAL 29095 BAYLEAF CIR BONder,GO WM4 PLOT PLAN 3 NTS MENIFEE.CA 303,447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE aI!ggo( UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS eInBU ARE LOCATED AS SHOWN. o.dde :addy SOLADECX WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL-14 (VERIFIED BY BUILDER) AC COMBRRR BO% SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE — AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL MIT HAMMERBACHER IDATH7.12.OL HERITAGE HEIGHTS REVIEWED BY:KIM ABCOUWER DATE17.12.05 CO NA,CA I92 DRIVE,#302 CORONA,CA 92879 REV.# BY DATE I DESCRIPTION VnaMCI,OLA, DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Steel INDIVIDUAL 29095 BAYLEAF CIR Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300 PLACARDS