PMT18-00614 City of Menifee Permit No.: PMT18-00614
29714 HAUN RD.
�CCEL/!? MENIFEE,CA 92586 Type: Residential Electrical
`- " t 911k"' MENIFEE Date Issued: 03/16/2018
PERMIT
Site Address: 29092 BAYLEAF CIR, MENIFEE, CA Parcel Number:
92584 Construction Cost: $6,315.48
Existing Use: Proposed Use:
Description of SOLAR TR 31582 HERITAGE HEIGHTS
Work: 8 MODULES,8 MICROINVERTERS,2.56kW
LOT 44
Owner Contractor
LENNAR HOMES OF CA, INC LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
SAMANTHA MAZELLA License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description Qtv Amount($)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee- Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK A. • •
I'Menifee
DATE:2/5/2018 PERMIT/PLAN CHECK NUMBER o-Tk _(JI J101
TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
ONEW OPLUMBING CRE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-2.56 kW, 8 pcs, Master Solar Permit No: PMT 17-00129
Plan No: 2131
PROJECTADDRESS 29092 Bayleaf Cir Zip 92584
ASSESSOR'S PARCEL NUMBER LOT 44 TRACr31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO
BUSINESS NAME Lennar Homes of California
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 6,315.48 SQ FT L SQ FT
APPLICANT'S SIGNATURE DATE 2/5/2018
DEPARTMENT DISTRIBUTION �Jry CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY:
PERMIT FEE �• W SMIP — GREEN f
PLAN CHECK FEE INVOICE TOTAL
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O-YES O NO
City of Menifee Building&Safety Department 29714 HDun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.560KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 8PCS. LG I LG320EIK-A5.(320W) BUYER:
INVERTER 1 8 PCS.I ENPHASE I 106PLUS-72-ACM-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE-
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 8 NA NA NA BUYER:
TILT IV NA' I NA* NA'
AZIMUTH 1 270• 1 NA• I NA' I NA' City of Menife:e DATE:
Building Dept. C; f y , MEI
FU 9 2012 FAALDI G A
Received CLAN A PRI
REVIEW
5'-6- 3'
'Approval of a ese pie
awrovRlcf,a VIOld
re0ationsan o*m
i jobsite until c
I
�g
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY) 'w
PV AC DISCONNECT (�
EXTERIOR-GARAGE b y—
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER) n
AC COMBINER BOX
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF Al
PLAN 2131 ELEVATION A-RIGHT ®
ORIENTATION I LOT#44
ORIGINAL BY:T HAMMERBACHER DATE:17.12.05
HERITAGE HEIGHTS LENNAR:
980 MONTELITO DRIVE.#302 REVIEWED BY:KIM ABCOUWER I DATE:17.12.05
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
;Pmarnast;6
feLM
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
INDIVIDUAL 4B Idw.0 a8 304
29092 E.CA F LIR Ba303.4 7. 30004
PLOT PLAN I/16'=I'-0- MENIFfE.CA 303.447.0300
SYSTEM LAYOUT
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY I MANUFACTURER MODEL NOTES TRADE
1 8 1 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR
2 1 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.240V.30A SOLAR
L I ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR.240V SOLAR
5 I ENPHASE X-IG-AMI-240-B AC COMBINER BOX SOLAR
b I ENPHASE T8D PV BREAKER,I X 20A-2P.I X SA-2P SOLAR
7 I CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR
8 I TBD TBD SERVILE PANEL,200A BUS BLDR. ELEL.
9 I TBD TBD UTILITY METER,IPH,120/240V.200A BLDR.ELEL.
10 I TBD TBD GROUNDING ELECTRODE,UFER BLOB.ELEL.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIO En
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMME
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 BUS RATING AMPS 200
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 MAIN DISCONNECT AMPS 20 1
TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 ALLOWED PV PER NEC AMPS 40
TEMP.DELTA LOW(TELLTA) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS:
MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) I.OA x 8(MODS)= 9.36A OF CORRENT
MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 9.36A x I.25= 11.70A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A MA12P 2 SPACE PV SACKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 2B0 lali nct be C0A
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 '�yy��.�,
NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 ;any n01N
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 This at al OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I >
COMPLIANCE AC MODULE SPEC U11741/ IEEE1547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD.OTY eC OTY 8
BRANCH CIRCUIT OUTPUT.IMAMC (IAC'MOD.GTV BC) AMPS(AC) 9.36
AC MODULE QUANTITY,TOTAL MOD.QTY T GTY 8
TOTAL SYSTEM OUTPUT IMAXTS OAC•MOD.QTY T) AMPS(AC) 1 9.36
CONDUCTOR SIZING CALCULATIONS
U CONDITION OF USE(COL): (AMPACITY ' TEMP.DERATE -FILL DERATE)VS.REQ'D(IMAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REG'D,(IMAX• 1.25)
KEY SIZE CU/AL INSULATION CALL' AMPACITY W/O TEMP. FILL RESULT REO'D OCD
TYPE DERATES DERATE DERATE (A) (A) USED(A)
A #12 CU THWN-2 COU 30 .76 1.0 22.80 9.36
TERM 25 25 11.10 20
B #10 LU NM-B COU Lx .91 1.0 36.40 9.36
TERM 35 35 11.70 20
C #10 CU NM-B COU 40 .91 1.0 36.40 9.36
TERM 35 35 11.70 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENPHASE Q CABLE,I-#6G,FREE AIR CU I UL3003,DG CABLE I ARRAY SOLAR
B 1 3-#10•,I-#10 EGC I LU I NM-B(ROMEX) I INTERIOR I SOLAR q
C 1 3-#10.1410 EGG I CU I NM-9(ROMEX) I INTERIOR I SOLAR
'NEUTRAL CAPPED AND NOT USED O—
co)
4 3Q
O 5W2P
gmiO 200.
O 6
mu 'x
GF
A a c c =10
L I I
ROOF EXTERIOR-GMAGE
ELECTRICAL DIAGRAM 2.56OKW
LOT#44
LENNAR: ORIGINAL BY:T HAMMERBACHER DATE:17.12.05
HERITAGE HEIGHTS
9B0 REVIEWED BY:KIM ABCOUWER DATE:17.12.05
N
CORONA,A,C CA A 92879 DRIVE,#302 REV.# BY DATE DESCRIPTION
ll�Pnionnusr,0
SOLI.
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571&o.CO8d"y Street
PLOT PLAN 2 NTS M9092 E,CA AF CIR BO303.4C030309
ELECTRICAL MENIFEE,CA 303.497.0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
40 SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND -
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-. .S�
11)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(11 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. _
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE, COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
r
� bepu
the(edwA I
ELECTRICAL NOTES: )Ped I 1xw"
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SMALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W7 ENPHASE MICRO-INVERTER SYSTEM.
ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SMALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT;-.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY to'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:T HAMMERBACHER DATE]I.12.0S
HERITAGE HEIGHTS LENNAR' REVIEWED BY:KIM ABCOUWER DATE17.12.05
980 MONTECITO DRIVE,#302it
CORONA,CA 92879 REV.# BY DATE DESCRIPTION •,
namasb6
,ouu.
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
ay Steel
INDIVIDUAL 4Bo der,COB304
PLOT PLAN 3 NTS 29092 E.CA F CIR BO303.4CO30006
NOTES MENIFEE.CA 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
OJT
for,or
or dhr
kept oalies
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOX
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 9.36A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
: ORIGINAL BY:T HAMMERBACHER DATE17.12.05
HERITAGE HEIGHTS LENNAR REVIEWED BY:KIM ABCOUWER DATE17.12.05
CO NA,CA I92 DRIVE.#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION tit
masb6
CLAY
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29092 BAYLEAF CIR Boulder,CO 80304
PLOT PLAN A NTS MENIFEE,U
PLACARDS 303.447.0300