Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-04411
City of Menifee Permit No.. PMT17-04411 29714 HAUN RD. Type: Residential Electrical <ACCELA-')' MENIFEE,CA 92586 MENIFEE Date Issued: 1211512017 PERMIT Site Address: 30465 BRISTOL GATE LN, MENIFEE,CA Parcel Number: 364-350-022 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of INSTALL SOLAR PV SYSTEM, 2.560KK 8 MODULES, 8 INVERTERS Work: TR 30422 LOT 41 Owner Contractor LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE SUITE 302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 LENNAR HOMES OF CALIFORNIA INC License Number:728102 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA92656 Phone:9493498269 Fee Description Qtv Amount f$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise slated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Blog_Permil_Templale.rpt Page 1 of 1 APPLICATION BUILDING & SAFETY PERMIT/PLAN CHECK ''Menifee DATE: 12/12/2017 PERMIT/PLAN CHECK NUMBER I" IT I -1 -C)q q TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- 2.560 kW, 8 pcs, Master Solar Permit No: PMT 16-00910 Plan No: 2129 PROJECTADDRESS 30465Bristol Gate Lane ZIP 92584 ASSESSOR'S PARCEL NUMBER 364-350-022 LOT 41 TRACT30422-3 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME Lennar Homes of California ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 6328*72 SQFT LSQFT APPLICANT'S SIGNATURE DATE 12/12/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENC&EERING FIRE ACCEPTED BY: PERMITFEE SMIP GREEN PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZEDLETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.dtyqfmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL / ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.560 KW Mike Dufaul[ LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 8PCS. LG LG320EIK-A5(3207) SrVPOpemt[ons INVERTER 1 8 PCS.l ENPHASE I06PLU5-72-ALM-US SSW 1001133 Class B BUYER: —_ ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 8 NA NA NA BUYER: TILT 23' NA' NA' NA' AZIMUTH 231- NA' NA. NA' DATE: 3' 11'-1, r I = I , - I I N h� I M I I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) W � PV AL DISCONNECT Q �' EXTERIOR-GARAGE ; SIR UTILITYMETER MAIN SERVICE PANEL (VERIFIED BY BUILDER) i m AC COMBINER BOX L-------- -- - 'RA ---- , u. UJI W � Q . -. a _ Z G m o W O z yL 9 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF � m PLAN 2129 ELEVATION A-LEFT ORIENTATION 3 LOT#41 MARIPOSA AT LENNAR: ORIGINAL BY:DESIREE WILLIAMS DATE:IJ.9.29 980 MONTECITO DRIVE.#302 REVIEWED BY:JIM PARKS DATE:17.9.29 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION namastl§ SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 der,Bruadway Street PLOT INDIVIDUAL 30465 BRISTOL GATE LANE BoWtle4 7. 30009 PLOT PLAN I I/16"= I'-0" MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES E6LDRELEC. 1 8 LG LG320EIK-AS(32OW) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER 2 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A 4 1 ENPHASE 10 ENVOY ENV-IGAMI-240 PV DATA MONITOR,IZOV 5 1 ENPHASE X-IG-AMI-240-B AC COMBINER BOX 6 1 ENPHASE TBD PV BREAKER.I X 20A-2P.I X SA-2P 7 1 CUTLER-HAMMER TBD PV BREAKER.I X 2OA-2P.RATING MAY VARY 8 I TED TBD SERVICE PANEL,200A BUS 9 1 TBD TBD UTILITY METER,IPH, 1201240V.200A BLDR.ELEC. 10 1 TBD TBD GROUNDING ELECTRODE,LIFER BDR. ELEC. II I TED TBD GROUNDING ELECTRODE. 690.47(D) SOLAR AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TOELTA) TMIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320EIK-A5(3207) I.I7A x II(MODS)= 9.36A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 9.36A x 1.25- IIJOA PEAK OUTPUT POWER STC IN AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 20ARP 2 SPACE PV SACXFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 .�,.-T� NOMINAL OUTPUT CURRENT(IAL) AC MODULE SPEC AMPS(AC) 1.17 Mike UfdUReR NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 Mikelt D OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I Sr VIS R COMPLIANCE AC MODULE SPEC ULI741 /IEEE1547 Uc#1001133 Clan B GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY BC OTY 8 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC'MOD.GTY BO) AMPS(AU 9.36 AC MODULE QUANTITY,TOTAL MOD.OTY T QTY 8 TOTAL SYSTEM OUTPUT IMAXTS OAC•MOD.OTY T) AMPS(AC) 1 9.36 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY'TEMP.DERATE 'FILL DEBATE)9S. REO'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.M.REQ'D,(IMAX• 1.25) KEY SIZEKCUIA� INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DERATES DERATE DEBATE (A7 (A) USED(A) A #12THWN-2 COU 30 0.76 1.0 22.80 9.36 TERM 25 25 11.70 20 B #10NM-B COU 40 0.91 1.0 36.40 9.36 TERM 350C *10NM-B COU 40 0.91 1.0 36.40 9.36 TERM 35 35 1 11.70 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TVPE LOCATION TRADE A 1-#12 ENPHASE Q CABLE,I-#6G,FREE AIR CU UL3003.DG CABLE ARRAY SOLAR B 3-#10, 1-#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR C 3-#10, 1-#10 EGC CU I NM-B(ROMEX) INTERIOR SOLAR 9 D 1-#6 GEC. 2016 CEC 690.47(D) CU I BARE INT/EXT SOLAR O NOTE:NEUTRAL CAPPED AND NOT USED 8 4 3Q O Se/zP O N© m z 0GR 'N D A B C C =OO _ II ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.56OKW LOT#41 LENNAR: ORIGINAL BY:DESIREE WILLIAMS DATE:17.9.29 MARIPOSA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:17.9.29 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION n SOL.. souv DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4B Ider,CBwd 8Street PLOT PLAN 2 NTS 30465 BRISTOL GATE LANE BoNO9P,CO B0004 ELECTRICAL MENIFEE,LA 303.447.0300 INSTALLATION NOTES: Mike Du(aulL SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. SFVPOpwaNOns 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. Lid)1001133 Oars B 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH Q')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2 1 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. ID 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 909C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703.IEC61646,IEC6I730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- I5)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS, 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 16)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- I9)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DESIREE WILLIAMS DATE)7.9.29 MARIPOSA AT LENNAR: REVIEWED BY:JIM PARKS DATE17.9.29 980 MONTECITO DRIVE,9302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namaste DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4571 Bmadway Sueel PLOT PLAN 3 NTS 30465 BRISTOL GATE LANE Boulder,0080304 NOTES MENIFEE,CA 303.447.0300 Mike Dufaul[ Sr VP OpereNons Licit 1001133 Class B CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.36A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DESIREE WILLIAMS DATEJ7.9.2 980 MONTECITO DRIVE,#302 9 MARIPOSA AT LENNAR: REVIEWED BY:JIM PARKS I DATE:17.9.29 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTIONti namasbe vo�ev DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmad y Street INDIVIDUAL 30465 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS