Loading...
PMT17-04404 City of Menifee Permit No.: PMT17-04404 29714 HAUN RD. T Residential Electrical -ACCELA�. MENIFEE,CA 92586 Type: MENIFEE Date Issued: 1 2/1 512 01 7 PERMIT Site Address: 30141 BRISTOL GATE LN, MENIFEE, CA Parcel Number: 364-370-007 92584 Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of INSTALL SOLAR PV SYSTEM-2.915 KW, 11 MODULES& 11 INVERTERS Work: CAMELLIA-LOT66 Owner Contractor LENNAR HOMES LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DRIVE SUITE 302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 LENNAR HOMES OF CALIFORNIA INC License Number:728102 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Q�t Amount tSl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 PERMIT/PLANBUILDING & SAFETY APPLICATION Menifee DATE: 12/12/2017 PERMIT/PLAN CHECK NUMBER — L TYPE: O COMMERCIAL O RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- 2.915 kW, 11 pcs, Master Solar Permit No: PMT 14-02630 Plan No: 2399 PROJECTADDRE55 30141 Bristol Gate Lane ZIP 92584 ASSESSOR'S PARCEL NUMBER 364-370-007 LOT 66 TRACT30422-3 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com APPLICANTNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO BUSINESS NAME Lennar Homes Of California ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE 951-817-3539 EMAIL samantha.mazella@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 7650.40 SQ FT LSO FT APPLICANT'S SIGNATURE DATE 12/12/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE p��I O SMIP UO GREEN 1 .00 PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED OYES O NO DRIVERS UCENSE# NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.915 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE II PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER I It PCS.1 ENPHASE I 106-60-2-US -- ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY II NA NA NA BUYER: TILT 23' NA' NA- NA° AZIMUTH 270' NA- NA' NA' DATE: 29'-B'ARRAY 30'-6'FLASHING 8'-8, 1 v t. TRANSITION LADECK WIRE TRANSITION BOX (UNDER ARRAY) 1 n PV AC DISCONNECT o m 2 EXTERIOR-GARAGE —— ? ) UTILITY METER 8 �+ __ __ MAIN SERVICE PANEL �. f r7; ' i 111_ (VERIFIED BY BUILDER) ' I---------- AC COMBINER BOX H o (EXTERIOR-GARAGE) o � N n d O O 9 N N v s doe s � � W N IN PLANE OF ROOF ®Z PLAN 2 ELEVATION A RIGHT ORIENTATION 4. LOT#66 LENNAR: ORIGINAL BY:KIM ABCOUWER DATE:IJ.10.04 CAMELLIA AT 980 REVIEWED BY:CHRISTINE MARTINI DATE:17.10.04 CA I 92 DRIVE.#302 THE LAKES CORONNA,A.CA 879 REV.# BY DATE I DESCRIPTION •, namasC6 souv DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway, 8 Street INDIVIDUAL MENI BRISTOL GATE LANE Boulder,C000 80004 PLOT PLAN I I/16'=I'-0' MENIFEE,CA 303.497.03W SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(THAR) ASHRAE 2% 'C 37 INV.MODEL INVERTER SPEC IQ6-60-2-US TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(A0 330 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS 00 48 TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 INV.OUTPUT V,(VAc MOM) INVERTER SPEC VOLTS(ACT 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.96 MOD.POWER STC(P) MODULE SPEC WATTS(130 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DC) 23B COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED ` MOD. OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(oc) 38.10 INV.QTY,MAX/BRANCH CCT. INV.QTYec QTY 11 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAxBC I(IAC-INV.QTYOC) I AMPS(AU 1 10.56 MOD. MAX VOLTAGE(VMAxMDD) (VOC t(TD'COEF)) VOLTS(UC) 41.18 INV.QUANTITY.TOTAL I INV.QTYT I OTY I II MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(OC) 5.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC`INV.QTYT) I AMPS(AC) 110.56 MOD. SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(DU 9.00 MOD. MAXIMUM CURRENT(IMAX) (Isc°1.25) AMPS(DOT 11.25 MIN.AMPACITY REG'D,PER NEC (IMAX' 1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY CITY MANUFACTURER MODEL NOTES TRADE 1 11 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 II ENPHASE IQ6-60-2-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IOAMI-240 PV DATA MONITOR,120V SOLAR 6 1 ENPHASE X-10-AMI-25-8 AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER,I X 20A-2P,I X 5A-2P SOLAR 8 I CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P.RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLOR. ELEC. 10 TBD T80 UTILITY METER,IPH.120/240V,200A BLOB. ELEC. II TBD TBO GROUNDING ELECTRODE,UFER BLOR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU):. (AMPACITY°TEMP.DEBATE•FILL BERATE)vs.REOT(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs. REQ'D.(IMAX° 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE DEBATES DEBATE DEBATE (A7 (A) UBED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 ID 22.80 10.56 ALLOWED PV PER NEC AMPS 40 TERM 25 25 1320 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COu 40 0.91 1.0 56.40 10.56 INTERCONNECTION CALCS: TERM 35 1 35 13.20 20 0.96A x IRMODS)° 10.56A OF CURRENT C #10 CU NM-B COU 40 0.91 11.0 136.40 10.56 IO.SbA X 1.25° 13.20A TERM 35 35 13.20 20 TIE-IN WITH A ZOA/2P 2 SPACE PV BACKFEED BREAKER CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL 1 TYPE i LOCATION 1 TRADE A 1-#12 ENPHASE Q CABLE,I-#6G,FREE AIR CU ULM=BIG CABLE ARRAY SOLAR B 3-#10,I-#10 EGG CU I NM-B(ROMEX) INTERIOR BOLAR 10 C I 3-#10, 1410 EGC CU I NM-8(ROMEX) I INTERIOR I SOLAR NOTE:NEUTRAL WPM AND NOT USED O- Q 5 O SA/2P 8 O 0O /2P O 20A/ N A B C C = II ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.915KW LOT#66 ORIGINAL BY:KIM ABCOUWER DATE:17.10.04 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:CHRISTINE MARTINI I DATE:17.10.04 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamasuii SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway SVeeU INDIVIDUAL 30141 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE.CA 303.447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(,9 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-- I1)26 GAUGE INTERLOCKING FLASHING'SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO.PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES:GENERAL- 0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730- 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING 7 PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE.OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:KIM ABCOUWER DATE17.1 LENNAR: 0.04 CAMELLIA AT REVIEWED BY:CHRISTINE MARTINI I DATE)7.10.04 980 MONTECITO DRIVE.#302 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION tit maMA. saiev DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571lder,C a8 Street PLOT PLAN 3 NTS MENU BRISTOL GATE LANE Ba303. C080004 NOTES MENIFEE.CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX (EXTERIOR-GARAGE) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 10.56A I PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY:KIM ABCOUWER DATEi7.10.04 CAMELLIA AT REVIEWED BY:CHRISTINE MARTINI DATH7.10.04 930 NA,CA I92 DRIVE,#302 THE LAKES CORONA,LA 92879 REV.# BY DATE DESCRIPTION •, namast6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 BroeNvay Street PLOT PLAN 4 NTS 30141 BRISTOL GATE LANE B —..CO 8D304 PLACARDS MENIFEE,CA 303.447.0300