PMT17-04264 City of Menifee Permit No.: PMT17-04264
29714 HAUN RD. Type: Residential Electrical
�l-�CCEL/-> MENIFEE, CA 92586
MENIFEE Date Issued: 01/02/2018
PERMIT
Site Address: 24793 COLDWATER CANYON TR, Parcel Number: 358-671-005
MENIFEE, CA 92584 Construction Cost: $7,626.00
Existing Use: Proposed Use:
Description of ROOF MOUNTED PV SOLAR,2.8801KW
Work: TR 32025
Owner Contractor
WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC
11870 PIERCE STREET SUITE 250 760 NORTHWEST 107 AVENUE
MIAMI, FL 33172
Applicant Phone:3054854110
SUNSTREET ENERGY GROUP LLC License Number: 1001133
760 NORTHWEST 107 AVENUE
MIAMI, CA 33172
Phone:3054854110
Fee Description QQt r� Amount(SI
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY • APPLICATION
- Menifee
DATE 11/20/2017 PERMIT/PLAN CHECK NUMBER PMT17-02705
TYPE: ❑COMMERCIAL O✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [-]SIGN
SUBTYPE: ❑ADDITION ALTERATION ❑DEMOLITION [Z]ELECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK 2.88OkW ROOF MOUNTED PV SYSTEM
PROJECT ADDRESS 24793 COLDWATER CANYON TRAIL
ASSESSOR'S PARCEL NUMBER 358-671-005 LOT 102 TRACT 32025
PROPERTY OWNER'S NAME WOODSIDE HOMES
ADDRESS 11870 PIERCE STREET SUITE 250
PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM
APPLICANT NAME KRISTEN MURRAY
ADDRESS 6531 IRVINE CENTER DR SUITE 200
PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM
CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES ✓❑NO
BUSINESS NAME SUNSTREET ENERGY GROUP LLC
ADDRESS 6531 IRVINE CENTER DR SUITE 200
PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM
CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B
VALUATION$ $7.626.00 SO FT 200 L SO FT
APPLICANT'S SIGNATURE "&iet& DATE 11/2012017
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN L SMIP
INVOICE /j0I'b �Q PAIDAMOUNT
AMOUNT Q�_t ��L OCASH OCHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# 0CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES C NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
"SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY I MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.880 KW I I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 9 PCS.1 LG I LG320EIK-A5(32OW) BUYER:
INVERTER 9 PCS.1 ENPHASE I 106PLUS-72-ACM-US
ROOF TYPE CONIC. TILE DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#MOM
MOD CITY 9 NA NA BUYER:
TILT 18° NA° NA°
DATE:
AZIMUTH 180° NM NA°
16'-9'ARRAY 2'-l'
f
C ITYNEIrret'3I79t11ARFAR
i P.UILDO&MB SAFE DE A TMENT _
PLAN APPROVAL SOON NOW
PV AC DISCONNECT
i EXTERIOR
`-GARAGE
REVI ,�pERe
I V
Zvi t
(VERIFIED BY BUILDER) WE
COMBI ER BO
aproval OI�IIM p�rM t�uM not be construed tp be permit for,or an
-oval of,any violallon of any provisions of the federal,state or city
i ,,afions■Id OrdIl-,F This set of approved plans must be kept on the
s site urrtll cwoWJoe°
NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 4 ELEVATION C-LEFT IV
ORIENTATION 3 LOT#102
WOODSIOE HOMES: ORIGINAL BY:KIM ABCOUWER DATE:17.11.14
DAKOTA AT REVIEWED BY:ARTHUR HICKS JEAM17.11.15
AUDIE MURPHY 11870 PIERCE STREET.SUITE#100 REV.# BY DATE DESCRIPTION a�
RIVERSIDE.CA 92505 namasCc
SMAP
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 24793 COLDWATER CANYON TRAIL Boulder,CO 80304
PLOT PLAN 1/16-=1'-0' MENIFEE.CA 303.447.0300
SYSTEM LAYOUT
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY I MANUFACTURER MODEL NOTES TRADE
1 9 1 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 1O6PLUS-72-ACM-US MICROINVERTER SOLAR
2 I 1 TBD TBD PV ROOF JUNCTION BOX,NEMA 3R SOLAR
3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V. 30A SOLAR
4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR
5 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR
6 1 ENPHASE TBD PV BREAKER, I X 20A-2P.I X 5A-2P SOLAR
7 1 CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.RATING MAY VARY SOLAR
B I TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC.
9 1 TBD TBD UTILITY METER.IPH.120/240V,200A BLDR. ELEC.
10 1 TBD I TBD I GROUNDING ELECTRODE.UFER I BLDR. ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200
TEMP.AMBIENT LOW(Tm110 ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200
TEMP, MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40
TEMP,DELTA LOW(TDELTA) TmIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20
MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS:
MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 1.17A x v(MODS)= 10.53A OF CNRRENT
MOD.POWER STC(P) AC MODULE SPEC WATTS(Oc) 320 1O.53a x 1.25= 13.16A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-iN WITH A 20AnP 2 SPACE PV BACKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT UAC) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC ULI741 / IEEE1547
GROUNDING AC MODULE SPEC ISOLATED
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20
AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD.QTY Bc OTY 9
2RANCN CIRCUIT OUTPUT.IMAXBC (IAC'MOD.QTY BC) AMPS(AC) 10.53
C MODULE QUANTITY,TOTAL MOD. OTY T OTY 9
TOTAL SYSTEM OUTPUT IMAXTs I 0Ac•MOD.OTY T) IAMPS(AC) I0.53
CONDUCTOR SIZING CALCULATIONS
1)CONDITION OF USE(COU): I (AMPACITY'TEMP.DERATE'FILL DERATE)vs.REO'D OMAXg20
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REO'D,(IMAx' 1.25)
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D
TYPE DERATES DERATE DERATE (A) (A) USED
A #12 CU THWN-2 COU 30 0.76 1.0 22,80 10.53
TERM 25 25 13.16
B #to CU NM-B COU 40 0.91 1.0 36.40 10.53
TERM 35 35 13.16 C #10 CU NM-B COU 40 0.91 1.0 36.40 10.53
ERM 35 35 13.16
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL 1
TYPE LOCATION TRADE O
p -#12 ENPHASE Q CABLE.1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR 9
B 3-#10',1-#10 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR
C 1 3-#10.I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O
'NEUTRAL CAPPED AND NOT USED
8
4 Q
O SA/2P 0
O6 2OA/2 '
2
20A/2
�N
G G
A B C C = 10
I I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.8BOKW
LOT#102
ORIGINAL BY:KIM ASCOUWER DATE:17.11.14
DAKOTA AT WOODSIDE HOMES: REVIEWED BY:ARTHUR HICKS DATE:17.11.15
1187 PIERCE STREET.SUITE#100
AUDIE MURPHY RIVERSIDE.CA 92505 REV.# BY DATE I DESCRIPTION
Vnamast36
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4671 Broadway Street
INDIVIDUAL 24793 COLDWATER CANYON TRAIL Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300
ELECTRICAL
INSTALLATION NOTES:
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,
APRIL 2016 EDITION
6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
8)PV PANEL HAS BEEN TESTED BASED ON UL 1703.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
IU ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS.
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90'C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
ID)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:KIM ABCOUWER DATE17.11.14
DAKOTA AT WOODSIDE HOMES: REVIEWED BY:ARTHUR HICKS DATE17.11.15
11870 PIERCE STREET.SUITE#100
AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION
t2namast;6
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: Steel
457I&n,CO 8 3N
INDIVIDUAL 24793 COLDWATER CANYON TRAIL Boulder,CO
PLOT PLAN 3 MS MENIFEE,CA 303.447.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
NEMA 3R JUNCTION BOX
(I'OUTSIDE ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER&
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOA
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 10.53A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:KIM ABCOUWER DATE17.11.14
DAKOTA AT WOODSIDE HOMES: REVIEWED BY:ARTHUR HICKS I DATE17.11.15
11870 PIERCE STREET,SUITE#100
AUD I E MURPHY RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION .
namastd
SOAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Brwdway Street
INDIVIDUAL 24793 COLDWATER CANYON TRAIL Boulder,CO 80304
PLOT PLAN 4 NTS MENIFEE,CA 303.44T030D
PLACARDS