Loading...
PMT17-04263 City of Menifee Permit No.: PMT17-04263 29714 HAUN RD. Type: Residential Electrical �CCELA�. MENIFEE, CA 92586 MENIFEE Date Issued: 01/02/2018 PERMIT Site Address: 24788 COLDWATER CANYON TR, Parcel Number: 358-370-014 MENIFEE, CA 92584 Construction Cost: $6.778.00 Existing Use: Proposed Use: Description of ROOF MOUNTED PV SOLAR, 2.56KW Work: TR 32025 Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET SUITE 250 760 NORTHWEST 107 AVENUE MIAMI, FL 33172 Applicant Phone:3054854110 SUNSTREET ENERGY GROUP LLC License Number: 1001133 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Phone:3054854110 Fee Description Q1 Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_BIdg_Pennit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION `Menifee DATE 1 11/20/2017 PERMIT/PLAN CHECK NUMBER PMT17-02705 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION []ALTERATION ❑DEMOLITION [Z]ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK 2.56kW ROOF MOUNTED PV SYSTEM PROJECT ADDRESS 24788 COLDWATER CANYON TRAIL ASSESSOR'S PARCEL NUMBER 358-370-014 LOT 63 TRAGT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑✓NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $6,778.00 SO FT 200 L SO FT APPLICANT'S SIGNATURE S DATE 11/20/2017 rYSTAFFUSEONLYM DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP MO AMO 0� PAIDAMOUNT UN d"� � O CASH C CHECK N O CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT CLASH ^CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER 0 YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-6 72-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 •SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SY STEM SIZE 2.560KW LOCATIONS INDICATED BY THE ILLUSTRATION.. MODULE 8 PCS.1 LG I LG320EIK-AS(320W) BUYER: INVERTER 1 8 PCS.1 ENPHASE I IO6PLUS-72-ACM-US ROOF TYPE I CONC. TILE DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 1 8 NA NA NA BUYER: TILT 27° NA* I NA* I NA' AZIMUTH 270° NA* NA* NA' DATE: a CITY OF MENIFEE n BUILDING AND S! PLAN APPROVA^ NEMA 3R JUNCTION BOX (1'OUTSIDE ARRAY) REVIEWED BY PV DISCONNECT EXTEE RIOR-GARAGE %T UTILITY METER& MAIN SERVICE PANEL r (VERIFIED BY BUILDER) 'Approval of these plans shall not he onstr he A approval of,any violation of any prov io the r AC COMBINER BOX rpida6ons and ordinances. This set proved pta ust he to lO N until completion. now ei NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN I ELEVATION C ENH-RIGHT ORIENTATION I LOT#63 DAKOTA AT WOODSIDE HOMES: ORIGINAL BY:KIM ABCOUWER DATE:17.11.14 11870 PIERCE STREET,SUITE#100 REVIEWED BY:ARTHUR HICKS I DATE:17.11.15 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namaStA SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4Bo Broadway,GO8Street INDIVIDUAL MENIF COLOWATER CANYON TRAIL Boulder,C08U009 PLOT PLAN I/16'=I'-0' MENIFEE.CA 303.497.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 8 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 1O6PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 TBD TBD PV ROOF JUNCTION BOX,NEMA 311 SOLAR 3 1 CUTLER-HAMMER DGZZIURB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR 4 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,240V SOLAR 5 1 ENPHASE X-IQ-AMI-240-8 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER, I X 20A-2P.I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER, IX 20A-2P,RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL.200A BUS BLDR. ELEC. 9 1 TBD TBD UTILITY METER,IPH,120/240V.200A BLDR.ELEC. 10 1 TBD I TBD I GROUNDING ELECTRODE,UFER I BLDR.ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALL UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE.CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST •C -27 PV OCPD DEVICE USED AMPS 1 20 MOD.MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) 1.17A X$(MODS)- 9.36A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(oc) 320 9.36A x 1.25= II.70A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20Al2F 2 SPACE Pv RACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 /IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY Bc QTY 8 BRANCH CIRCUIT OUTPUT.IMAXBC (IAC-MOD.OTY sC) AMPS(AC) 9.36 AC MODULE QUANTITY,TOTAL MOD. QTY T OTY 8 TOTAL SYSTEM OUTPUT IMAXTS I OAC-MOD.OTY T) I AMPS(AC) 1 9.36 CONDUCTOR SIZING CALCULATIONS D CONDITION OF USE(COU): I (AMPACITY• TEMP. DERATE'FILL DERATE)vs.REQ'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.Vs.REQ'D,(IMAX - 1.25) KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A Z#12CUTHWN-2 COU 30 0.76 1.0 22.80 9.36 TERM 25 25 11.70 20 B NM-B COU 40 0.91 1.0 36.40 9.36 TERM 35 35 11.70 20 C NM-S COU 40 0.91 1.0 36.40 9.36 TERM 35 35 11.70 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENPHASE 0 CABLE, -#6G,FREE AIR CU UL3003.DG CABLE ARRAY SOLAR 0 B 1 3-#10•. I-010 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR C 1 3410, 1-#10 EGC I GU I NM-B(ROM EX) INTERIOR SOLAR M 'NEUTRAL CAPPED AND NOT USED Q 4 O3 (D SA 2P 0 O © 2car2 F 2 20A/2 N A B C C to- ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.560KW LOT#63 DAKOTA AT WOODSIDE HOMES: ORIGINAL BY:KIM ABCOUWER DATE:17.11.14 11870 PIERCE STREET.SUITE#100 REVIEWED BY:ARTHUR HICKS DATE:17.11.15 AUDIE MURPHY RIVERSIDE.CA 92505 REV.# BY DATE I DESCRIPTION �Pnamast;6 SOLAq DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4573 Broa ay Street 24788 COLDWATER CANYON TRAIL Booker,CO 80304 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH W)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ID ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND.LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646. IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IN MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT}'. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10', BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:KIM ABCOUWER DATE17.11.14 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:ARTHUR HICKS GATEi7.11.15 1IB70 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION �2amasGe roue DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway 8 Street INDIVIDUAL 24780 COLDWATER CANYON TRAIL Boulder, PLOT PLAN 3 1'FS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA 3R JUNCTION BOX U'OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER.) LqL AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.36A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:KIM ABCOUWER DATE:17.11.IL DAKOTA AT WOODSIDE HOMES: REVIEWED BY:ARTHUR HICKS DATE:I7AI.IS 11870 PIERCE STREET,SUITE 9100 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BV DATE DESCRIPTION bnamasGe sovnv DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway SBeet INDIVIDUAL 24788 COLDWATER CANYON TRAIL Boulder,CO 803N PLOT PLAN L PITS MENIFEE,CA 303.447.03DO PLACARDS