Loading...
PMT17-03883 City of Menifee Permit No.: PMT17-03883 29714 HAUN RD. T Residential Electrical <A— =LAB. MENIFEE, CA 92586 ype' MENIFEE Date Issued: 11/06/2017 PERMIT Site Address: 24824 COLDWATER CANYON TR, Parcel Number: 358-370-017 MENIFEE,CA Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of SOLAR TR 32025 DAKOTA-PLAN 3 Work: 9 MODULES, 9INVERTERS,2.880 KW Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET SUITE 250 760 NORTHWEST 107 AVENUE MIAMI, FL 33172 Applicant Phone: 3054854110 MENIFEE,CA License Number: 1001133 Phone: 9494505840 Fee Description Qty Amount I$) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requidng the correction of errors in the plans and specifications or from preventing builiding operations being pried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 • & SAFETY PERM IT/PLAN APPLICATION Menifee DATE 10/30/2017 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILE HOME POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION []ALTERATION ❑DEMOLITION ❑✓ ELECTRICAL [-]MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK 2.880kW ROOF MOUNTED PV SYSTEM PROJECT ADDRESS 24824 COLDWATER CANYON ASSESSOR'S PARCEL NUMBER 358-370-017 LOT 66 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑✓NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $7,626.00 SO FT 200 L SO FT APPLICANT'S SIGNATURE '\&"tn' DATE 10/30/2017 DEPARTMENT DISTRIBUTION ) CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I / SMIP VV INVOICE {(00 PAIDAMOUNT AMOUNT U . ;.► OCASH OCHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.BBO KW LOCATIONS INDICATED BY THE ILLUSTRATION, MODULE 9 FCS.I LG I LG320EIK-A5(320W) BUYER: INVERTER 9 PCS.1 ENPHASE I 106FLUS-72-ACM-US ROOF TYPE CONC. TILE DATE: SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 5 4 NA NA BUYER:. TILT 23" 23° NA' NA° AZIMUTH 197° 197- NA' NA' DATE: } NEMA 3R JUNCTION BOX 4' 13'-5'ARRAY V 10'-I'ARRAY W (I'OUTSIDE ARRAY) I IN W La Q (— s N PV AC DISCONNECT _ p S• p• , EXTERIOR-GARAGE Da c e E A UTILITY METER fl Q �� a a MAIN SERVICE PANEL LU .o v (VERIFIED BY BUILDER) _ W a o 0 a in AC COMBINER BOX > _ W $ o 1� Q s a W Uj Y/ LL. in W q W Q ir C9 0 � za W s �� o o 3 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF z W y n JQ W PLAN 3 ELEVATION ENH-LEFT ORIENTATION I DAKOTA AT WOODSIDE HOMES: ORIGINAL BY:CHRISTINE MARTINI DATE:I7.10.27 II870 PIERCE STREET.SUITE#100 REVIEWED BY:JIM PARKS DATE:17.10.27 Vnamast6 AUDIE MURPHY RIVERSIDE.CA 92505 REV.# BY DATE I DESCRIPTION OIAt DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway SBeel ZLB24 COLDWATER CANYON TR. PLOT PLAN I I/16'=I'-0' MENIFEE.CA Boulder,CO 80304303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 9 LG LG320EIK-AS(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 2 TBD TBD PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IOAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-10-AMI7240-8 AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER,I X 2OA-2P, I X 5A-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL, 200A BUS BLDR. ELEC. 9 1 TBD TBD UTILITY METER.[PH, 120/240V,200A BLDR.ELEC. 10 1 TBD I TBD I GROUNDING ELECTRODE.UFER IBLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% -C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TEEST) MODULE SPEC 'C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TOELTA) THIN-TTEsT •C -27 PV OCPD DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(3257) I.17A X 9NOD5)= 10.53A OF CI.RRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DO 320 10.53A X I2s= 13.'A PEAK OUTPUT POWER STC IN AC MODULE SPEC WATTS(AC) 290 TIE-IN INITH A ZOARP z SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC IN AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741/IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD.QTY BC QTY 9 BRANCH CIRCUIT OUTPUT, IMAXBO (IAC•MOD.QTY Bc) AMPS(AC) 10.53 AC MODULE QUANTITY,TOTAL MOD. OTY T 0TY 9 TOTAL SYSTEM OUTPUT IMAXTs (IAc•MOD. QTY T) AMPS(AC) 10.53 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COLD: I (AMPACITY• TEMP.DERATE•FILL DERATE)V . REO'0(TMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REDID.(IMAX• 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 I TEMP. FILL RESULT REO'D OCD TYPE DERATES DEBATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.53 TERM 25 25 13.16 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 10,53 TERM 35 35 13.16 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 20 CONDUCTOR SCHEDULE KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENPHASE Q CABLE, 1-#6G,FREE AIR CU I UL3003,DG CABLE I ARRAY I SOLAR B 1 3-#10•,I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 9 C 1 3410, 1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 'NEUTRAL CAPPED AND NOT USED O O 8 0 O 4 3O G SAP Q 20N ,oAl �N G G A B [ c 0 ROOF EXTERIOR-GARAGE - ELECTRICAL DIAGRAM 2.88OKW LOT#66 ORIGINAL BY:CHRISTINE MARTINI DATE:17.10.27 DAKOTA AT WOODSIDE HOMES:11870 PIERCE STREET,SUITE#100 REVIEWED BY:JIM PARKS I DATE:17.10.27 AUDIE MURPHY RIVERSIDE.CA 92505 REV.# BY DATE I DESCRIPTION •� b namasCe ..IA. DWG TITLE: rPAGEFNTS CALE: SITE LOCATION:INDIVIDUAL 4571 Wer,B. CO ryStreet PLOT PLAN 24824 COLDWATER CANYON TR. BouWeg C080300 ELECTRICAL MENIFEE,CA 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}•)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY 7 SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IU ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING 15 LIMITED TO PV ARRAY FOOTPRINT W1 ENPHASE MICRO-INVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122, 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. i 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED-PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:CHRISTINE MARTINI DATE7 11870 7.10.27 DAKOTA AT HOMES: REVIEWED BY:JIM PARKS DATE17.1027 870 PIERCE CE STREET.SUITE#100 AUDIE'MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namasCEi DWG TITLE: PAGE*: I SCALE: SOLAR SITE LOCATION: 4571 Broadway Street INDIVIDUAL 24824 COLDWATER CANYON TR. Boulder,CO 803N PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. NEMA JR JUNCTION BOX (1'OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX aa SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 10.53A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION DSIDE HOMES: ORIGINAL BY:CHRISTINE MARTINI DATE17.10.27 WOO DAKOTA AT WOO PIERCE STREET.SUITE#100 REVIEWED BY:JIM PARKS DATEJ7.10.27 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION Vnamast;d 601AY DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4671 Broadway Street INDIVIDUAL 24824.COLDWATER CANYON TR. Boulder,C080304 PLOT PLAN 4 NTS MENIFEE.CA PLACARDS 303.447.0300