Loading...
PMT17-03882 City of Menifee Permit No.: PMT17-03882 29714 HAUN RD. �ACCELA� MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 11/06/2017 PERMIT Site Address: 24817 COLDWATER CANYON TR, Parcel Number: 358-671-003 MENIFEE,CA Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of SOLAR TR 32025 DAKOTA-PLAN 3 Work: 9 MODULES, 9 INVERTERS,2.880 KW Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET SUITE 250 760 NORTHWEST 107 AVENUE MIAMI, FL33172 Applicant Phone:3054854110 MENIFEE, CA License Number: 1001133 Phone:9494505840 Fee Description Clty Amount f51 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise slated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Perrdt Template.rpt Page 1 of 1 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.880 KW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 9 PCS.1 LG I LG320EIK-A5(320W) BUYER: INVERTER 9 PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE I CONC.TILE DATE: --- SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD CITY 9 NA NA NA BUYER: TILT 23• NA• NA' NA° AZIMUTH 198° NA' NA' NA• DATE' 6'-0' 30'-2'ARRAY I' Z — g W g }� NEMA 3R JUNCTION BOX (I'OUTSIDE ARRAY) LL • AA E Q L PV AC DISCONNECT ((� v EXTERIOR-GARAGE i N G 4 UTILITY METER 8 MAIN SERVICE PANEL W C (VERIFIED BY BUILDER) LL a6 N W N J — m It— AC COMBINER BOX W Q y c LTVi G 0 Z m Z W a' it m •� E c t� m o LL Z Q 3 a G Z W o o = Q > eLU w VNOPDIPR SIONS AR OWN IN PURE OF 401`2� PLAN 3 ELEVATION A OPT-RIGHT ORIENTATION 3 LOT#100 ORIGINAL BY:CHRISTINE MARTINI DATE:17.10.27 DAKOTA AT WOODSIDE HOMES: 11870 PIERCE STREET.SUITE#100 REVIEWED BY:JIM PARKS I DATE:17.10.27 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION ti namastAl souv DWG TITLE: PAGE#: 1 SCALE: SITE LOCATION: 4571 Broadway Sbeel INDIVIDUAL 24817 COLDWATER CANYON TR. Boulder,CO 80304 PLOT PLAN 1 1/I6'=1'-0' MENIFEE.CA 303,447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES TRADE 1 9 1 LG LG320EIK-A5(320W) ACPV MODULE W/INTEGRATED ENPHASE 106PLUS-72-ACM-US MICROINVERTER SOLAR 2 1 TBD TBD PV ROOF JUNCTION BOX,NEMA 3R SOLAR 3 1 CUTLER-HAMMER DG221LJRB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR 4 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR.240V SOLAR 5 1 ENPHASE X-IG-AMI-240-B AC COMBINER BOX SOLAR 6 1 ENPHASE TBD PV BREAKER, I X 20A-2P,I X SA-2P SOLAR 7 1 CUTLER-HAMMER TBD PV BREAKER, I X 204-.2P.RATING MAY VARY SOLAR 8 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 9 1 TBD TBD UTILITY METER, IPH,120/24OV,200A BLDR.ELEC. 10 1 TBD I TBD I GROUNDING ELECTRODE.UFER I BLDR.ELEC. El AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP.AMBIENT HIGH(THAR) ASHRAE 2% •C 37 BUS RATING AMPS 200 TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TEELTA) THIN-TTEST "C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD.PART NUMBER AC MODULE SPEC LG320EIK-A5(320W) I.DA x 9(MODS)- 10.53A OF OKIPRENT MOD.POWER STC(P) AC MODULE SPEC WATTS(x) 320 10.53A%I.25= I].I6A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 T1E-1N WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAc) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-6D.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 /IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY.MAX PER BRANCH CIRCUIT MOD. QTY Bc OTV 9 BRANCH CIRCUIT OUTPUT.IMAXBC (IACMOD.OTY BW AMPS(AC) 10.53 AC MODULE QUANTITY,TOTAL MOD. OTY T OTY 9 TOTAL SYSTEM OUTPUT(MARTS (IAC°MOD.OTY T) AMPS(AC) 10.53 CONDUCTOR SIZING CALCULATIONS D CONDITION OF USE(COU): (AMPACITY-TEMP. DERATE° FILL DERATE)vs.REQ'D((MAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REO'D.((MAX* 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP, FILL RESULT REO'D OCD TYPE DEBATES DEBATE DEBATE (A) (A) USED(A) A X#12CUTHWN-2 COU 30 W61j... 22.80 10.53 TERM 2525 13.16 20B NM-B COU 40 36.40 10.53 TERM 3535 13.16 20C NM-B COU 40 36.40 10.53 TERM 3535 13.16 20 CONDUCTOR SCHEDULE KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENPHASE 0 CABLE,1-#66,FREE AIR CU I UL3003.DG CABLE I ARRAY I SOLAR B 1 3-#10•, I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR N(;M C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR •NEUTRAL CAPPED AND NOT USED 8) 0 4 O 0 I OZZR 12OV21 z 6A z � N GTim G __ 11 a e c c z 10 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.BBGKW LOT# 100 ORIGINAL BY:CHRISTINE MARTINI DATE:17.10.27 DAKOTA AT WDODSIDE HOMES:11870 PIERCE STREET.SUITE#100 REVIEWED BY:JIM PARKS I DATE:17.10.27 AUDIE MURPHY RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION inamast6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Street PLOT PLAN 2 NTS MEN( COLDWATER CANYON TR. Boulder,CO O30304 ELECTRICAL MENIFEE,CA 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)WIRE TRANSITION JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 6)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 7)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 8)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)BASE ATTACHMENT AND FLASHING TO BE INSTALLED.PER MANUFACTURER'S SPECIFICATIONS. IU ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE, 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. IZ)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND.WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:CHRISTINE MARTINI DATE17.10.27 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:JIM PARKS DATE17.10.27 11870 PIERCE STREET,SUITE#100 AUDIE MURPHY RIVERSIDE,CA92505 REV.# BY DATE DESCRIPTION timasti§ OIA! DWG TITLE: PAGE#: I SCALE: SITE LOCATION: treet INDIVIDUAL a677 Ber.CO8cWay 304 PLOT PLAN 3 NTS MENI COLOWATER CANYON TR. BOWBB4 7080304 NOTES MENIFEE,CA 303.407.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. N11—NEMA SR JUNCTION BOX 0'OUTSIDE ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877—SLR—POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 10.53A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI I DATE:17.10.27 DAKOTA AT WOODSIDE HOMES: REVIEWED BY:JIM PARKS I DATE:17.10.27 11870 PIERCE STREET.SUITE#100 AUDI E MURPHY RIVERSIDE.CA 92505 REV.# BY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4871&o,CO8 304 PLOT PLAN 4 NTS MENI COLDWATER CANYON TR. Boulder,CO PLACARDS MENIFEE.CA 303.447.0300