Loading...
PMT17-03814 City of Menifee Permit No.: PMT17-03814 29714 HAUN RD. Type: Residential Electrical �/-\CCELA— MENIFEE,CA 92586 MENIFEE Date Issued: 1 012 612 01 7 PERMIT Site Address: 29662 EDGEMERE WAY, MENIFEE, CA Parcel Number: 364-360-054 92584 Construction Cost $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES, 1 INVERTER,2.39 kW LOT 218 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA92656 Fee Description gyt Amount ISl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a peril for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE:10/18/2017 PERMIT/PLAN CHECK NUMBER TYPE: O COMMERCIAL ESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA OSIGN SUBTYPE: 9 r66ITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 1769 -2.39 KW/9 PCS Master Solar Permit No. PMT16-00910 PROJECT ADDRESS 29662 Edgemere Way ZIP 92584 ASSESSOR'S PARCEL NUMBER 364-360-054 LOT 218 TRACT30422-3 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremlah.acaytUrrl@Ierlrlar.Com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME 980 Montecito Dr., Sufte 302, Corona CA 92879 ADDRESS 980 Montecito Dr., Suite 302,Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B / c7�Q7 VALUATION$ SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 10/18/2017 9 DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE PERMIT FEE �-1� d SMIP GREEN PLAN CHECK FEE INVOICE TOTAL 3� OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION ✓�,�J BUYER ACKNOWLEDGES HOME THE SOLAR MODULES TO BE INSTALLED IT OTY MFR. MODEL Mike Ouhult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW Sr VPOperatlons LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 9PCS. HYUNDAI I HIS-S265RG(265W) UOIW103 CImB BUYER- INVERTER 9 PCS.1 ENPHASE I M215-60-2LL-522-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ��I O"F ME IF MOD OTY 9 NA NA BUYER: D 1 TILT 23• NA' NA• s� -. l7 AZIMUTH 182' NA" NA- DATE: ' City of g DeMenpt. . t ;1AN w VA Building Dept. OCT 2 5 2017 ` Received rppi oval ofthese lanssl approval of,any h lation( regulations and or inance jobsite until COMPS lion. F----------------------1 16'-S'ARRAY 17'-3'FLASHING 1 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV DISCONNECT 8 EXTERIOR-GARAGE Ito UTILITY METER Q ,may MAIN SERVICE PANEL ice+ L J (VERIFIED BY BUILDER) —___J 1 �e NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N I® PLAN 1769 ELEVATION C RIGHT ORIENTATION I LOT#eld ORIGINAL BY: JIM PARKS DATE:I7.0 .OL MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER DATE:17.05.05 CORONA. AT THE LAKES 980 DRIVE.#302 A.C CA A 92879 REV.# BY DATE I DESCRIPTION nomasb6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL Bo B0 4 Broadway Street Y EDGEMERE WAY Boulder,CO009 PLOT PLAN I/Ib'=I'-0' MENIFENIFEE.CA 30.A.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC •C. 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(ad 48 TEMP.DELTA LOW(TOELTA) THIN-TTEST 'C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(Aa) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, Inc INVERTER SPEC AMPS(AC) 0.9 D MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE MOD.POWER PTC MODULE SPEC WATTS(OC) 258 COMPLIANCE INVERTER SPEC UL174IAEEEI547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 1 31.30 INV.GROUNDING INRTER ISOLATED MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(OC) 38.10 INV.OTY,MAX/BRANCH CCT. INV.VE SPEC OTY" 1 OTY 1 9 MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/•C -0.114 BRANCH CCT.OUTPUT, IMAX3C I UAC'INV.GTYBc) I AMPS(AC) 1 8.10 MOD.MAX VOLTAGE(VMAxMOo) (VOc+(TO'COEF)) VOLTS(OC) 41.18 INV. QUANTITY,TOTAL I INV.QTYT I OTY 1 9 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(D0) 8.50 TOTAL SYSTEM OUTPUT,]MARTS I(IAC•INV.GTYT) I AMPS(AC) 1 8.10 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(130 9.00 MOD.MAXIMUM CURRENT(IMAX) (ISc• 1.25) AMPS(OC) 11.25 MIN.AMPACITY REO'D,PER NEC (MAX•1.25) AMPS(130 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE !0(he cons 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR ,y OVlslon 2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR his et of a; 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILIN METER.IPH,120/24OV,200A BLDR.ELEC. 12 I TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 I TBD I TBD I GROUNDING ELECTRODE.690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I(AMPACITY-TEMP.DERATE `FILL DERATE)vS. REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.W. REQ'D.(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A d12CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20B CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20C CU NM-B COU 40 0.91 L0 1 36.40 8.10 TERM 35 1 1 35 10.13 20 MISS,OuFault Sr VPOperallons CONDUCTOR SCHEDULE UG8001A3 ClassB KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3410.1410 EGC CU NM-8(ROMEX) INTERIOR SOLAR C 3410, 1410 EGC CU NM-8(ROMEX) INTERIOR SOLAR D CATSE,ETHERNET CABLE CU CATSE INTERIOR OLAR S E 1-#6GEL,2010 LEG 690.47(D) CU BARE EXTERIOR SOLAR 5 6 II 7 • c O SEE NOTE 15 0 ® ( IO O ® 20 a O 'N ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 KW LOT#218 LENNAR: ORIGINAL BY: JIM PARKS DATE:17.05.04 MARIPOSA 980 REVIEWED BY:KIM ABCOUWER DATE:17.05.05 AT THE LAKES CORONNA.A.C LA A 92 DRIVE,#302 879 REV.# BY DATE DESCRIPTION •, SOLAR namast6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: SOoet INDIVIDUAL 4571lder,D aB ON PLOT PLAN 2 NTS MENIF EDGEMERE WAY Boulder, TC3lX1 4 ELECTRICAL MENIFEE,LA 303.4470300 t STRUCTURAL NOTES: Mike Default SOLAR CONTRACTOR- 5r VPOPerade05 D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Uce1001133 pane 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE- 6)THE MANUAL.UNIRAC AR 3o PUB RACKING S STEMJANU AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION p RTM 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 1,01 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, I 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. .410 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. d t be a pei th federal, )vec plans m( ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE, SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: JIM PARKS DATE:I .05.04 MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER DATE:17.05.05 CORONNA,A,C CA AT THE LAKES 980 I DRIVE,#302 A 92879 REV.# BY DATE DESCRIPTION VnamOS136 iOtAi DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29662 EDGEMERE WAY Boulder,CO 80304 PLOT PLAN 3 NITS CA 3 MENIFEE. NOTES 03.417.0300 ��J It Mike Duhult Sr VP Operadoiu uc#iaD3iBB 0asse CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE IT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. DA ,o n .e or city be kept on th SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8J A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: JIM PARKS DATE:17.05.04 MARIPOSA LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ABCOUNER DATE:17.05.05 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbIS sou. DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Street PLOT PLAN 4 NTS MENIF EDGEMERE WAY Bo303,4ider, 7080304 PLACARDS MENIFEE,LA 303.447.0300