PMT17-03814 City of Menifee Permit No.: PMT17-03814
29714 HAUN RD. Type: Residential Electrical
�/-\CCELA— MENIFEE,CA 92586
MENIFEE Date Issued: 1 012 612 01 7
PERMIT
Site Address: 29662 EDGEMERE WAY, MENIFEE, CA Parcel Number: 364-360-054
92584 Construction Cost $6,328.72
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 MARIPOSA
Work: 9 MODULES, 1 INVERTER,2.39 kW
LOT 218
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA92656
Fee Description gyt Amount ISl
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a peril for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
Menifee
DATE:10/18/2017 PERMIT/PLAN CHECK NUMBER
TYPE: O COMMERCIAL ESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA OSIGN
SUBTYPE: 9 r66ITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit- Plan 1769 -2.39 KW/9 PCS
Master Solar Permit No. PMT16-00910
PROJECT ADDRESS 29662 Edgemere Way ZIP 92584
ASSESSOR'S PARCEL NUMBER 364-360-054 LOT 218 TRACT30422-3
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL jeremlah.acaytUrrl@Ierlrlar.Com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO
BUSINESS NAME 980 Montecito Dr., Sufte 302, Corona CA 92879
ADDRESS 980 Montecito Dr., Suite 302,Corona, CA 92879
PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
/ c7�Q7
VALUATION$ SQ FT L SQ FT
APPLICANT'S SIGNATURE DATE 10/18/2017
9
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE
PERMIT FEE �-1� d SMIP GREEN
PLAN CHECK FEE INVOICE TOTAL 3�
OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofmenifee.us
SYSTEM INFORMATION
✓�,�J BUYER ACKNOWLEDGES HOME
THE SOLAR MODULES TO BE INSTALLED
IT OTY MFR. MODEL Mike Ouhult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.385 KW Sr VPOperatlons LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 9PCS. HYUNDAI I HIS-S265RG(265W) UOIW103 CImB
BUYER-
INVERTER 9 PCS.1 ENPHASE I M215-60-2LL-522-IG
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ��I O"F
ME IF
MOD OTY 9 NA NA BUYER: D 1
TILT 23• NA' NA• s� -. l7
AZIMUTH 182' NA" NA- DATE: '
City of g DeMenpt.
.
t ;1AN w VA
Building Dept.
OCT 2 5 2017 `
Received rppi oval ofthese lanssl
approval of,any h lation(
regulations and or inance
jobsite until COMPS lion.
F----------------------1
16'-S'ARRAY
17'-3'FLASHING
1 SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV DISCONNECT
8 EXTERIOR-GARAGE Ito
UTILITY METER Q
,may MAIN SERVICE PANEL
ice+ L J (VERIFIED BY BUILDER)
—___J 1
�e
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
I®
PLAN 1769 ELEVATION C RIGHT
ORIENTATION I LOT#eld
ORIGINAL BY: JIM PARKS DATE:I7.0 .OL
MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER DATE:17.05.05
CORONA.
AT THE LAKES 980 DRIVE.#302
A.C CA A 92879 REV.# BY DATE I DESCRIPTION
nomasb6
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL Bo B0
4 Broadway Street
Y EDGEMERE WAY Boulder,CO009
PLOT PLAN I/Ib'=I'-0' MENIFENIFEE.CA 30.A.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC •C. 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(ad 48
TEMP.DELTA LOW(TOELTA) THIN-TTEST 'C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(Aa) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, Inc INVERTER SPEC AMPS(AC) 0.9 D
MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE
MOD.POWER PTC MODULE SPEC WATTS(OC) 258 COMPLIANCE INVERTER SPEC UL174IAEEEI547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 1 31.30 INV.GROUNDING INRTER ISOLATED
MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(OC) 38.10 INV.OTY,MAX/BRANCH CCT. INV.VE SPEC OTY"
1 OTY 1 9
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/•C -0.114 BRANCH CCT.OUTPUT, IMAX3C I UAC'INV.GTYBc) I AMPS(AC) 1 8.10
MOD.MAX VOLTAGE(VMAxMOo) (VOc+(TO'COEF)) VOLTS(OC) 41.18 INV. QUANTITY,TOTAL I INV.QTYT I OTY 1 9
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(D0) 8.50 TOTAL SYSTEM OUTPUT,]MARTS I(IAC•INV.GTYT) I AMPS(AC) 1 8.10
MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(130 9.00
MOD.MAXIMUM CURRENT(IMAX) (ISc• 1.25) AMPS(OC) 11.25
MIN.AMPACITY REO'D,PER NEC (MAX•1.25) AMPS(130 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(oc) 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY MANUFACTURER MODEL NOTES TRADE !0(he cons
1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR ,y OVlslon
2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR his et of a;
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
II I TBD TBD UTILIN METER.IPH,120/24OV,200A BLDR.ELEC.
12 I TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC.
13 I TBD I TBD I GROUNDING ELECTRODE.690.47(D) SOLAR
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): I(AMPACITY-TEMP.DERATE `FILL DERATE)vS. REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): I AMPACITY AT TERMINALS.W. REQ'D.(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALL AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A d12CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40
TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20B CU NM-B COU 40 0.91 1.0 36.40 8.10
TERM 35 35 10.13 20C CU NM-B COU 40 0.91 L0 1 36.40 8.10
TERM 35 1 1 35 10.13 20 MISS,OuFault
Sr VPOperallons
CONDUCTOR SCHEDULE UG8001A3 ClassB
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A I-#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR
B 3410.1410 EGC CU NM-8(ROMEX) INTERIOR SOLAR
C 3410, 1410 EGC CU NM-8(ROMEX) INTERIOR SOLAR
D CATSE,ETHERNET CABLE CU CATSE INTERIOR OLAR S
E 1-#6GEL,2010 LEG 690.47(D) CU BARE EXTERIOR SOLAR
5 6 II
7 • c O
SEE NOTE 15 0
® ( IO
O ® 20 a
O
'N
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.385 KW
LOT#218
LENNAR: ORIGINAL BY: JIM PARKS DATE:17.05.04
MARIPOSA 980 REVIEWED BY:KIM ABCOUWER DATE:17.05.05
AT THE LAKES
CORONNA.A.C LA A 92 DRIVE,#302 879 REV.# BY DATE DESCRIPTION •,
SOLAR
namast6
DWG TITLE: PAGE#: SCALE: SITE LOCATION: SOoet
INDIVIDUAL 4571lder,D aB ON
PLOT PLAN 2 NTS MENIF EDGEMERE WAY Boulder, TC3lX1 4
ELECTRICAL MENIFEE,LA 303.4470300
t
STRUCTURAL NOTES: Mike Default
SOLAR CONTRACTOR- 5r VPOPerade05
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Uce1001133 pane
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE-
6)THE
MANUAL.UNIRAC
AR 3o PUB RACKING
S STEMJANU AND
SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION p RTM
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 1,01
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS, I
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. .410
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION. d t be a pei
th federal,
)vec plans m(
ELECTRICAL NOTES:
GENERAL-
D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE,
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT k
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: JIM PARKS DATE:I .05.04
MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER DATE:17.05.05
CORONNA,A,C CA
AT THE LAKES 980 I DRIVE,#302
A 92879 REV.# BY DATE DESCRIPTION
VnamOS136
iOtAi
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29662 EDGEMERE WAY Boulder,CO 80304
PLOT PLAN 3 NITS CA 3
MENIFEE.
NOTES 03.417.0300
��J It
Mike Duhult
Sr VP Operadoiu
uc#iaD3iBB 0asse
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE IT
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
DA
,o n
.e or city
be kept on th
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER e
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8J A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: JIM PARKS DATE:17.05.04
MARIPOSA LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ABCOUNER DATE:17.05.05
AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbIS
sou.
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway Street
PLOT PLAN 4 NTS MENIF EDGEMERE WAY Bo303,4ider, 7080304
PLACARDS MENIFEE,LA 303.447.0300