PMT17-03813 City of Menifee Permit No.: PMT17-03813
29714 HAUN RD. T Residential Electrical
'�ACCELA? MENIFEE, CA 92586 Type:
MENIFEE Date Issued:
10/2612017
PERMIT
Site Address: 29638 EDGEMERE WAY, MENIFEE, CA Parcel Number: 364-360-053
92584 Construction Cost: $6,328.72
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 MARIPOSA
Work: 9 MODULES, 1 INVERTER,2.39 kW
LOT 217
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description O_yt Amount(S)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pennit_Template.rpt - Page 1 of 1
PERMIT/PLANBUILDING & SAFETY APPLICATION
Menifee
DATE:10/18/2017 PERMIT/PLAN CHECK NUMBER
TYPE: O COMMERCIAL XESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: �DITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit- Plan 1769 -2.39 KW/9 PCS
Master Solar Permit No. PMT16-00910
PROJECT ADDRESS 29638 Edgemere Way ZIP 92584
ASSESSOR'S PARCEL NUMBER 364-360-053 LOT 217 TRACT30422-3
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANTNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? OYES ONO
BUSINESS NAME 980 Montecito Dr.,Suite 302, Corona CA 92879
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL leremiah.ecayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
2
VALUATION$ SQ FT L SQ FT
APPLICANT'S SIGNATURE DATE 10/18/2017
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY71
PERMIT FEE aj �/ SMIP ( '� GREEN f
L
N CHECK FEE INVOICETOTAL
R BUILDER VERIFIED O YES O NO DRIVERS LICENSE## NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92S86 951-672-6777
www.cityofinenifee.us
SYSTEM INFORMATION
'✓�,i7 J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL Mike DuhulL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.385 KW I I Sr VPOWmtlons LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 9 PcS.1 HYUNDAI I HIS-S265RG(265W) I U01001133 CIMB BUYER:
INVERTER 1 9 PCS.1 ENPHASE I M215-60-2LL-S22-IG
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION - ; IY�(L f
/r NI[
ARRAY#1 ARRAY#2 ARRAY#3 MEN
IF
QTY 9 NA NA BUYER-
TILT
R.
TILT 23• NA° DING N E
AZIMUTH 1 175° 1 NA* DATE:
NA' 7 N A OV,
City of Menifee
Building Dept. R '!;EWE
OCT 2 5 2017
1p;uovalofthem plans
Received approval of,any vi lation
regulations and or linance
johsite until compl tion.
---- -----t
16'-5-ARRAY
IT-3-FLASHING
i�
SOLADECK WIRE _
TRANSITION BOX
(UNDER ANSIT ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE y +
UTILITY METER B
MAIN SERVICE PANEL + I 1
(VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF AI
®V
PLAN 1769 ELEVATION A LEFT
ORIENTATION I LO #21
ORIGINAL BY: JIM PARKS DATE:17.05.04
MARIPOSA LENNAR: REVIEWED BY:KIM ABLOUWER DATE:17.05.05
CORONNA,A,C LA
AT THE LAKES 980 I2 DRIVE.#302
A 9879 REV.# BY DATE DESCRIPTION
namasCC
SOLAR
DWG TITLE: ]�PAG* [SCALE, SITE LOCATION:
INDIVIDUAL 4571 Broadway Street
PLOT PLAN 0' 2963B EDGEMERE WAY Boulder,CO 80304
SYSTEM LAYOUT MENIFEE.CA 303,447.0300
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(00 48
TEMP,DELTA LOW(TOELTA) TMIN-TTEST 'G -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AD) 240 i.
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 AF1
N i l C
MOD. POWER.STC(P) MODULE SPEC WATTS(00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I a�
MOD. POWER PTC MODULE SPEC WATTS 00 238 COMPLIANCE INVERTER SPEC UL174I/IEEE1547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT.VOLTAGE(V00 MODULE SPEC VOLTS(DO 38.10 INV.OTY,MAX/BRANCH CCT. INV OTY'C OTY 9
MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.IIL BRANCH CCT.OUTPUT,IMAXB[ (IAc'INV.QTVBU AMPS(AC) 8.10
MOD. MAX VOLTAGE(VMAXMOD) (VOC+(TD'COEF)) VOLTS(00 41.18 INV.QUANTITY.TO! I INV.OTYT OTY 9
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(oc) 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I (IAC•INV.QTYT) AMPS(AC) 8.10
MOD,SHORT CCT.CURRENT(ISC) MODULE SPEC AMPS(00 9.00
MOD. MAXIMUM CURRENT(IMAX) (ISC-1,25) AMPS(00 11.25
MIN.AMPACITY REG'D,PER NEC (MAX• 1.25) AMPS(oc) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DG) 1 15
ELECTRICAL EQUIPMENT SCHEDULE not h constr
KEY QTY MANUFACTURER MODEL NOTES TRADE
1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR ny prc itisions I
2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR this se of a
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR PPI
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 TBD TBD SERVICE PANEL.MIN. 125A BUS BLDR.ELEC.
II TBD TBD UTILITY METER, MIN.
120/Z40V,ZOOA BLDR.ELEC.
12 TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC.
13 1 1 1 TBD I TBD I GROUNDING ELECTRODE.690.47(D) I SOLAR
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU): (AMPACITY•TEMP. DERATE•FILL DERATE)VS.REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REO'D.(IMAX•1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200
TYPE DERATES OERATE DERATE (A) (A) USED.(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40
TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10
TERM 35 35 I0.13 20 ^\ n
C #10 CU NM-B COU 40 0.91 1 1.0 36.40 8.10
TERM 35 1 35 10.13 20 Mike Dutault
Sr VP Owmdons
CONDUCTOR SCHEDULE UCY 2001133 Class
KEY CONDUCTORS CU/ OCATION TRADE
A 1-#12 ENGAGE CABLE, I-#6G,FREE AIR !*W
ARRAY SOLAR
B 3-#10.1-#10 EGG INTERIOR SOLAR
C 3-#10.1-#10 EGC INTERIOR SOLAR
D CATSE,ETHERNET CABLE INTERIOR SOL4R
E -#6GEC,2010 CEC 690.47(D) CUEXTERIOR SOLAR
5 6 11
7 a o a O_
SEE NOTE 15 10
0
ISNIP
O O O O td>/2
s - L IN
G G�
r ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.385XW
LOT#217
ORIGINAL BY: JIM PARKS DATE:17.05.04
MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER DATE:17.05.05
CORONNA,LA
AT THE LAKES 980 A.CA I 92 DRIVE.#302
879 REV.# BY DATE DESCRIPTION If
.�
n SOLA2
sosav
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway CO8 Street
PLOT PLAN 2 NTS MENIF EOGEMERE WAY Boulder, 7030304
ELECTRICAL
MENIFEE,CA 303.447.0300
STRUCTURAL NOTES: Mike Duhult
SOLAR CONTRACTOR- Sf VPOperatlons
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. L101MI133 CIM8
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT,
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION ARTI
MANUAL,VERSION 227.3,PUB 140113-ICC.JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2-)BEYOND.THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. f
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION. to be alp
e federal
pimse
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE.CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SMALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS:WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS,
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT a'.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: JIM PARKS DATE:17.05.04
MARIPOSA REVIEWED BY:KIM ABCOUWER DATE:17.05.05
AT THE LAKES CORONA.30 A9287CITO RIVE,#302
CORONA,LA 92879 REV.# BY DATE I DESCRIPTION •�
namast;6
sou.
DWG TITLE: PAGE #: I SCALE: SITE LOCATION:
umet
INDIVIDUAL 4571 Broadway 304
PLOT PLAN 3 NTS 29638 EDGEMERE WAY Bo303.4C08004
NOTES MENIFEE,CA 03.447.0300
���
Mike 0ufault
Sr VP OPemtioas
UUI 1001133 [lass 8
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE ENT
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
I DE
ut for,or a
ate or city
t be kept on he
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8.1 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY: JIM PARKS DATE
980 MONTECITO DRIVE,#302 :17.05.04
MARIPOSA REVIEWED BY:KIM ASCOUWER DATE:17.05.05
AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTIONti namasbAR
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway Street
INDIVIDUAL 29638 EDGEMERE WAY B.Idw.CO 80304
PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300
PLACARDS