Loading...
PMT17-03811 City of Menifee Permit No.: PMT17-03811 29714 HAUN RD. '/ACCEL/47 MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 10/26/2017 PERMIT Site Address: 29623 EDGEMERE WAY, MENIFEE, CA Parcel Number: 364-360-008 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES, 1 INVERTER,2.39 kW LOT 28 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Qtv Amount fSl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Templale.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION ,4 r=Menifee DATE:10/18/2017 PERMIT/PLAN CHECK NUMBER ?Mt- 05m TYPE: O COMMERCIAL FSIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: t�VVITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 1769 -2.39 KW/9 PCS Master Solar Permit No. PMT16-00910 PROJECTADDRESS 29623 Edgemere Way ZIP 92584 ASSESSOR'S PARCEL NUMBER 364-360-008 LOT 28 TRACT30422-3 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME 980 Montecito Dr.,Suite 302,Corona CA 92879 ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 10/18/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BURRING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE I a Leo SMIP GREEN PLAN CHECK FEE INVOICE TOTAL 3,LOU OWNER BUILDER VERIFIED O YES G NO DRIVERS LICENSE tl NOTARIZED LETTER 0 YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityqfmenifee.us SYSTEM INFORMATION ^ ✓�y J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITY MFR. MODEL Mike Duhult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 1Z385KW Sr VPOReray., LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS.1 HYUNDAI I HIS-S265RG(265W) Ud 2001133 [IassB BUYER; INVERTER 1 9 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 !ARRAY#3 CITY OF MENI EE MOD OTY 9 NA NA BUYER: TILT 23• 1 NA* I NA' DATE: N SA AZIMUTH 175• NA- NA• PLAN APPRO AL City of Menitee Building Dept. REVIEWED BY 4 OCT 2 5 2017 `Approval of these plan shall o Received approval of,any violatio of any regulations andordina es. Thi jobsite until completion ------------------- t 29'-B'ARRAY 30'-6'FLASHING II'-2' WIRE TRRANSITIOANSITIO N BOX (UNDER ARRAY) GIIIIIIIAD NIIIIIMI& PV AC DISCONNECT EXTERIOR-GARAGE I UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) I I L--------� L--- NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1769 ELEVATION B LEFT ORIENTATION NON 3 LOT#28 1 ORIGINAL BY: JIM PARKS DATE:17.05.04 MARIPOSA LENNAR: 980 REVIEWED BY:KIM ASCOUWER DATE:17.05.05 AT THE LAKES CORONNA.A,C CA A 92879 DRIVE,#302 REV.# I BY DATE I DESCRIPTION •, namas.� sauv DWG TITLE: PAGE AH SCALE: SITE LOCATION: 4571 Broadway SBeN INDIVIDUAL 29623 EDGEMERE WAY B.Ider,CO 80304 PLOT PLAN I 1/16'= 1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMA%) ASHRAE 2% 'C 37 INV-MODEL INVERTER SPEC M215-6D-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN •C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AG) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC •C 25 INV. INPUT V.Noe MAX) INVERTER SPEC VOLTS IN) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST •C -27 INV.OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(Ac) 240 MOD-MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(ID0 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(00 258 COMPLIANCE INVERTER SPEC UL17411 EEE1547 DI MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(9U 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(oc) 38.10 INV.QTY.MAX/BRANCH CCT. INV.GTYBc OTY 9 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/•C -0.114 BRANCH CCT.OUTPUT,IMAXBC (IAC•INV.QTYBC) AMPS(Ad 8.10 MOD.MAX VOLTAGE(VMA%MGD) (VOC+(TO•COEF)) VOLTS(OC) 41.18 INV. QUANTITY,TOTAL INV.OTYT OTY 9 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(OC) 8.50 TOTAL SYSTEM OUTPUT.IMAXT$ I(IAC'INV.QTYT) IAMPS(A[) 8.10 MOD.SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(OW 9.00 MOD. MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(oc) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX•1.25) AMPS(oU 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(OC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR constru 2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0796-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR V$ions 01 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR It f appra 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I%I5A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER,I-H.120/24OV,200A BLDR.ELEC. 12 TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 TBD TBD GROUNDING ELECTRODE.690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS Q CONDITION OF USE CCOU): I(AMPACITY•TEMP.DERATE•FILL DEBATE)vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.M REQ'D,(IMAX• 1.25) PANEL MFR- CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REWD OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 30 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #10 LU NM-B COU LO 0.91 L0 36.40 8,10 TERM 35 35 10.13 20 \ L #10 1 CU I NM-B COU 1 40 0.91 1.0 36.40 8.10 TERM 135 35 10.13 1 20 I Mike Ouhult 5r VPOpemtIGns CONDUCTOR SCHEDULE U01MI133 ClassB KEY .CONDUCTORS I CU/AL TYPE I LOCATION I TRADE A 1-#12 ENGAGE CABLE,1-#6G,FREE AIR 1 CU TC-ER ARRAY SOLAR B 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10, 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR D CAT5E.ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR E I-#SGEC.2010 CEC 690.47C) I CU I BARE I EXTERIOR I SOLAR 5 6 II SEE NOTE 15 10 8 O ISOp 2 O O O O 20AIff } L G G JM� 13= E A B C =12 I I Atl6F EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385%W LOT#28 ORIGINAL BY: JIM PARKS DATE:17.05.0E MARIPOSA LENNAR: 980 MONTELITO DRIVE.#302 REVIEWED 8Y:KIM ABCOUWER I DATE:17.05.05 it AT THE LAKES CORONA,CA 92979 REV.# BY DATE I DESCRIPTION stA •� n io'AR DWG TITLE: PAGE#: SCALE: Street SITE LOCATION: 4577 Broadway CO8 Street INDIVIDUAL MENIF EDGEMERE WAY Boulder,C080309 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 303.44Z0"AO STRUCTURAL NOTES: Mike Default SOLAR CONTRACTOR- Sr VP OPeraHons D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Utl11001133 ❑assB 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC.SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3,PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. RTM 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. II�1 be a per federal,i i 31anilnu ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A MATIO14ALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD, 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W7 ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIG14AGE- I6)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT pt'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: JIM PARKS DATE:I . LENNAR: 05.04 MARIPOSA REVIEWED BY:KIM ASCOUWER I DATE:17.05.05 AT THE LAKES 980 I DRIVE,9302 CORONA.NA.CA CA 92 92879 REV.# BY DATE DESCRIPTION •� namast� scree DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4671 Broadway Street PLOT PLAN 3 NTS 296E3 EDGEMERE WAY Boulder,C0304 03 NOTES MENIFEE.CA 303.447.0300 ���� Mlke OeFael[ Sr VP Operz[ions Ucp 1001133 Class B CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS 1T ARE LOCATED AS SHOWN. 6�—wo `or,or an or city e kept on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 6 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8.1 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: JIM PARKS DATE:17.05.04 MARIPOSA LENNAR: 980 MONTECITO DRIVE.$302 REVIEWED BY:KIM ABCOUWER I DATE:17.05.05 AT THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION •� namast;A. DWG TITLE: PAG111SCALE: some SITE LOCATION: 4B Idw,BroadmyBSOeet INDIVIDUAL 29623 EDGEMERE WAY Bwlder,CO B0304 PLOT PLAN 4TS PLACARDS MENIFEE.CA 303.447.0300