Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-03807
City of Menifee Permit No.: PMT17-03807 29714 HAUN RD. �I-►CCELi, MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 1 012 6/2 01 7 PERMIT Site Address: 29683 EDGEMERE WAY, MENIFEE, CA Parcel Number: 364-360-004 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES, 1 INVERTER,2.39 kW LOT 24 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO OR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description QQrt Amount 1$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27,00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried an thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION . Menifee DATE:10/18/2017 PERMIT/PLAN CHECK NUMBER 8O TYPE: O COMMERCIAL JkRESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: 'ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 2129 - 2.39 KW/9 PCS Master Solar Permit No. PMT16-00910 PROJECT ADDRESS 29683 Edgemere Way ZIP 92584 ASSESSOR'S PARCEL NUMBER 364-360-004 LOT 24 TRACT30422-3 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL ]eremiah.acayturri@lennar.com APPLICANTNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES C NO BUSINESS NAME 980 Montecito Dr., Suite 302, Corona CA 92879 ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@Iennar.com CONTRACTOR'S STATE LIC�JN�U7MBBER 728102 LICENSE CLASSIFICATION A&B 72. VALUATION$ 6, S SQ L So FT APPLICANT'S SIGNATURE DATE 10/18/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE C 93, SMIP �- GREEN �. PLAN CHECK FEE INVOICE TOTAL a��, L#0 OWNER BUILDER VERIFIED O YES O NO DRIVERS LICENSE#t I NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION -✓�,�J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITYMFR. MODEL Mike Du6ult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385KW I I SrVPOpendens LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9PCS.9PCS. ENPHASE HYUNDAI HiS-S265RG(265W) LIWIM103 CimB BUYER: INVERTER M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE- SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 1 ARRAY#3 MOD OTV 1 9 1 NA NA BUYER: O ME 23° NA' NA- DATE: AZIMUTH 270' NA' NA' LDI G A City of Mendee PLAN A .pR( Building Dept. RI OCT 2 5 2017 REVIEW l Received 'Approval ofth seplar approval of,any vjoletic regulations and wdinan i jobsite until com ole'tioh, I i — I � I I � rI I TRANSITION SOLADECK WIRE TRRANSITIO I O N BOX I g (UNDER ARRAY) I I I I � O PV AC DISCONNECT EXTERIOR-GARAGE � UTILITY METER 8 ' MAIN SERVICE PANEL (VERIFIED BUILDER) + NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN TAT N ELEVATION B LEFT ORIENTATION 3 LOT#24 I ORIGINAL BY: JIM PARKS DATE:17.05.04 MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER II.OS.OS DATE: AT THE LAKES 980 NA,CA I92 DRIVE,#302 CORONA,CA 879 REV.# BY DATE DESCRIPTION Vnomasui§ SOIAe DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4577 Bmetlway SVeet 29683 EDGEMERE WAY Boulder,CO BD3D4 PLOT PLAN 1116'=1'0' MENIFEE.CA 303A47.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(oa) 48 TEMP,DELTA LOW(TEELTA) TnIN-TTEST •C -27 INV. OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(AO) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DD) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DC) 238 1 COMPLIANCE INVERTER SPEC LL1741/IEEEI547 E MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 38.10 INV. QTY.MAX/BRANCH CCT. INV.QTYBC OTY 9 AFE MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC WPC -0.114 BRANCH CCT.OUTPUT.IMAXBC (IAC-INV.QTYBC) AMPS(AC) 8.10 MOD.MAX VOLTAGE(VHAXMOD) (Vac+(TD`COEF)) VOLTS Inc) 41.18 INV.QUANTITY,TOTAL INVATYT I OTY 9 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT.(MARTS (IAC`INV.QTYT) AMPS(AU 1 8.10 MOD. SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(Oc) 9.00 MOD.MAXIMUM CURRENT OMAX) (Isc` 1.25) AMPS(Dd 11.25 MIN.AMPACITY REQ'D,PER NEC ((MAX` 1.25) AMPS(DC) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE is KEY OTY MANUFACTURER MODEL NOTES TRADE 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR ail not be I 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR II d y p(OVI! 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR T is set OI 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER,IPH,120/240V.200A BLOB.ELEC. 12 I TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. 13 1 TBD I TBD I GROUNDING ELECTRODE,690.47(D) I SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF UBE(COU): (AMPACITY•TEMP.OERATE`FILL DEBATE)v5.REQ'0((MAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.a_REO'D,((Max° 1.25) PANEL Ml CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE DERATES DEBATE DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 B.IO TERM 35 35 110.13 20 MIRe Default CONDUCTOR SCHEDULE Uc#001133 Class8 KEY CONDUCTORS CU/AL I TYPE I LOCATION I TRADE A 1-#12 ENGAGE CABLE, 1-#6G,FREE AIR CU TC-ER ARRAY SOLAR 8 3-#10,1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR D CATSE,ETHERNET CABLE CU CAT5E INTERIOR SOLAR E 1-#6GEC,2010 CEC 690.47(D) CU I BARE I EXTERIOR SOLAR 5 © I 7 • o O SEE NOTE 15 10 ® flWip I 2 9 O O O 1DO 3 I 13 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385xW LOT#24 ORIGINAL BY: JIM PARKS DATE:17.05.04 MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER DATE:17.05.05 AT THE LAKES CORONA, NA,CA I92 DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, n SOLAR souv OWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Street PLOT PLAN 2 NTS MENIF EDGEMERE WAY Boulder,C030304 ELECTRICAL MENIFEE.CA 003.M7.0300 STRUCTURAL NOTES: Mike OW[oB SOLAR CONTRACTOR- Ir VP Operdtlons U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. UCH IM123 ❑ass e 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40% ROOFING CONTRACTOR- f EPAR D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. cr d to be i so the Wei prc jed phrro ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SMALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703. IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. W)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM- I)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: JIM PARKS DATE:I .05.04 MARIPOSA 980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ABCOUWER I DATE:17.05.05 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasGA - ti SOLA[ DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Steel INDIVIDUAL 29683 EDGEMERE WAY Boulder.CO BO&M PLOT PLAN 3 NTS MENIFEE.CA 303.417.0300 NOTES Mike 0uhul[ 3 VPOpemtions Uc#1001133 am 8 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. MENT VAK DATE rmit for,or a state or city SOUDECKst be kept o the TRANSITION WIRE N BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8.1 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: JIM PARKS DATE:17.05.04 MARIPOSA LENNAR: REVIEWED BY:KIM ABCOUWER DATE:17.05.05 AT THE LAKES CORONA. NA.CA I92 DRIVE,#302 CORONA,CA 92879 REV.# BY GATE DESCRIPTION •, co namaste SOLAR DWG TITLE: PAGE #: SCALE: SITE LOCATION: INDIVIDUAL 4B Bel,C08dway Street PLOT PLAN 4 NTS MENIF EDGEMERE WAY B31dee,COB0304 PLACARDS MENIFEE,CA 303.497.0300