Loading...
PMT17-03586 City of Menifee Permit No.: PMT17-03686 29714 HAUN RD. 47%CCELA— MENIFEE, CA 92586 Type: Residential Addition MENIFEE Date Issued: 10/O6/2017 PERMIT Site Address: 26012 PALM BREEZE LN, MENIFEE, CA Parcel Number: 335-520-038 92586 Construction Cost: $3,500.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of CONSTRUCT 12'X 40'CITY STANDARD SOLID PATIO COVER, NO ELECTRICAL Work: Owner Contractor GUSTAVO GUERRA , 26012 PALM BREEZE LN MENIFEE, CA 92586 Applicant License Number: GUSTAVO GUERRA 26012 PALM BREEZE LN MENIFEE,CA 92586 Phone: 9512696793 Fee Description Qtv Amount 1$) Building Permit Issuance 1 27.00 Deck/Patio, standard 1 83.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Building 1 4.15 $116.115 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penally of perjury that I am under provisions of with a licensed contractur(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from Iicensure under the Contractor's State License Law for Professions Code and my license is In full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for worker's 7044 of the Buy sin and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application')su itt or at the following website: by Section 3700 of the Labor Code,for the performance of work for which this permit is issued. www.le in .c ."goy w. tml. Policy# X OR AUTHORIZED AGENT Date G� 6 ❑I have and will maintain worker's compensator insurance,as required by PRO OWNER section 3700 of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the following:I am the property this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this number are: application and the information I have provided is correct.I agree to comply Carrier with all applicable city and county ordinances and state laws relating to building const cti .I author" a representatives of this city or county to Policy# Expires enterth a el ntifi pr ertyfor inspection purposes. (This section need not to be completed is the permit is for one-hundred dollars($100)or tens Date P'E— OPERTY OWNERO ORIZED AGENT ❑I certify that In the performance of the work for which this permit is issued, I shall not emolov any persons in any manner was to become subject to the CITY BUSINESS LICENSE# worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the worker's compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a Applicant Date mixture containing a hazardous material equal to or greater that the amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE 15 ❑Yes ❑No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($300,OD0),IN r o ion occupant require a permit for the construct modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SC ion or See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the /� rding agency for the performance of the work which this permit is issued outer boundary of a school? ' (Section 3097 Civil Code) ❑Yes ❑No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of Contractor's License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25505 and 25534 concerning 1'r checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 hazardous material reporting. Business and Professions Code).Any city or county that requires a permit to oYes ❑No Date construct,alter,improve,demolish or repair any structure,prior to Its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to fife a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING(RRP) License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their as owner of the prop, rty,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: �l compensation,will do(!)all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractor's State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or Improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or Improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions \Bede:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. ♦ SAFETY PERMIT/PLAN APPLICATION 'pe.dry City of Menitee Building & Safety Dept. N Aenifee DATE: PERMIT/PLAN CHECK NUMBER ' v ✓ �" F TYPE:'? -:C.COMJ!41KIAL 'RESIDENTIAL 0 MULTI-FAMILY . MOBILE HOME C POOL/SPA Q SIGN SUBTYPE: P4QDITION O ALTERATION 'O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING Q RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK _12OL40 t"'}Lr"�- I Z.( )( LjO I PROJECTADDRESS �s'eezep LN ZIP z»L ee ASSESSOR'S PARCEL NUMBER 33 SS 20-6,3e_ 1 LOT 11 TRACT 3 O OWNER NAME (pNUU k/Mo Cluema.4 ADDRESS (A O ICj (3e2✓e C Gi /t't,Qrt ( ecA 2-Ls- P-4 PHONE C951 0?6 l r 6 713 EMAIL 5'*Vv, u e'frr,L(7 °L' 0 Ccs7+ APPLICANT NAME ' 1VID C��. f t ADDRESS G�ZItt L'LQ /�l{Nt .¢� �- y2„r�� PHONE '73-1 ) Z_6 / -L _7g-3 EMAIL US VU va:frC—g7 U Cv CONTRACTOR'S NAME OWNER BUILDER? 0 YES C) NO BUSINESS NAME ADDRESS PHONE EMAIL CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION VALUATION $ O SO FT L SQ FT APPLICANT'S SIGNATURE DATE 1016117 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE PERMIT FEE � SMIP GREEN PLAN CHECK FEE INVOICETOTAL OWNER BUILDER VERIFIED "YES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O. NO I,VloA I.Crpiq,r.;er,i;a.Lts 2X SOLID BLOCKING REQUIRED FOR 2X2 OR 2X4 P3"O.C.MIN.SPACING ALL SOLIDPATO COVERT W/MIN(3) RAFTERSPACING: — ROOF SLOPE:V"PER FOOTMIN. L4TTCEOR'H'NOMINAL PLV WOOD EDGE NAIL PLYWOOD W/W 1 CETOOR EQUAL HEADER,ORA34 WITFI BUILTLPOR ROLL ROOFINGI SEETABLE•A" NAILS 0 W D.C.(STANDARD 6"/ JIIr�_II OR EQUAL FRAMING ANGLES 12"rvnlurvc ELSEWHEM) ' ` SIMPSON H2(OR EQUAU f SIMPSON(OR EQUAU �.24..�( HURRICANE CLIPS 0 IBLOGC EADER SPAN&SDE: 24" SEETABLE-B^ PUSTCAPSOR ,dA)( a LEDGER: SEE TABLE -D^ B MAX 7 STRAP LT OVERHANG FRAMING DEfAIL9(PG.0OVERHANG 'h"DIA.TiRIUI RU BOLTS KNEEBRACE: -------" -, ORIB:NAILS CL.FIRANCE: SEE FRAMING U-S"MIN. BETAILSIP13.2) RAFTER SPAN&SIMSEE TABLE^A e'-O"MAX. EXISTING WOOD ______________________________________ STUD WALL TYPICAL CQW MN Be GF-USE "4 POSTS SIMPSONCBSQ.PBS _ ____ 3'/z"CONCRETE OR EQUAL W/BOLTS/ MIN SCREWSMAILS PER SLAB TYPICAL._ SLOPE P MFG.SPECS. iIMU i Ia 6X4 POST fi P M i u e &IP1A { I"STANDOFF BE IIWEEM'.—___.__- ONCRETEAND WOOD POST --- FOORNGSZE: SEETABLE-C- FRONT VIEW `-------------------------------------' SIDE VIEW TABLE TTATT TABLE TTBTT TABLE ITCTT TABLE TTDTT RAFTER SPANS HEADER SIZE & SPANS FOOTING SIZE LEDGER (DOUGLAS FIR#2 OR BETTER) (DOUGLAS FIR#2 OR BETTER) BOLTING SIZE SPACING SPAN BASED ON 1000 ALL LAG BOLT RAFTER H R P.S.F. SOIL BEARING SHALL HAVE TA SPAN PRE-DRILLED SPAN SIZE PRESSURE. HOLES- BEE NOTE 2 x4 1211 O.C. 9'-1 O" -&-O"MAX- X B - 8"S . X 12" DEEP 3/8" DIA. X 5' 16" O.C. 8'- 1 1" UP TO 1 O'-O" MAX 4 x 8 18"SQ. X 12" DEEP 3/8"LON DI . 51 24" O.C. 7-SIT 12'-0" 12'-0" MAX x 10 18" SQ.X 12" DEEP STAGGERED 32"O.C. IT6'-3" 14'-0" MAX x 12 18" SQ.X 12" DEEP 2x6 1211O.C. 15'-4" 12' 1*' AX 4x B 24" SO.X 12" DEEP ) 3/8" DIA X 5" 16" O.C. 13'-9" TO 1 O%0T. MAX 4 x 10 24"SQ.X 12" DEEP LONG AT 1 " 24" O.C. 1 1'-3" 12'-0" MAX 4 x 12 24"SQ.X 12" DEEP 32" O.C. "9'-7" 20'-0" 14'-0" MAX 4 x 14 2 x 8 1211 O.C. 20'-0" NOTES: 1 6" O.C. 1 8'- 2" _ 1 TWO 2X MEMBERS MAY BE SUBSTITUTED FOR ONE 4X HORIZONT 24"O.C. 14'- 1 O" FRAMING MEMBER. 32" O.C. 12'-8" 2 LAG BOLTS MUST FULLY ENGAGE A WOOD STUD OR RIM JOIST AND 2 X 1 0 12" O.C. 20'-O" PROVIDED WITH APPROPRIATE WASHERS. LAG BOLTS SHALL BE LOCATED 16" O.C. 20'-0" MINIMUM OF 1-1/2"FROM THE TOP OR BOTTOM OF THE LEDGER. 24" O.C. 181- 1 1" 2"O.C. 16'-2" 3. NOT DESIGNED TO BE ENCLOSED-ADDITIONAL ENGINEERING ANALYSIS WILL BE REQUIRED IF ENCLOSED. ' 4 X 4 1 $7PEM 4..WA PAGE 2FOF 2 FOR CONSTRUCTION DETAILS. 4s" o.c. 7'-s TYWARJNNERT 4 X 6 $wpl _ 1, ALTERNATE PATIO DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH ENGINEERED ANALYSIS. USE OF THIS CONVENTIONAL STANDARD DESIGN I 3 " O.C. i 3'-9" HE USER'S ISK D CARRIES NO IMPLIED OR INFERRED GUARANT 48" O.C. IT 1 I I- F S. 4X8 32" O.C. `18'-2" RnrowmF Courrrr Cone umFowan Paorawuf 48" O.C. 14'- 1 O" CITY OF MENIFEE *4pproval of these plans shall not be construed to be a per it for, BUILDING DEPARTMENT THP SPACING AND SPAN, . ,PP IS FOR' LATTICE ARS�Ylslons of the federal,s to or N'F_ regICOVERINGS ONLY. :his set of approved plans MU be ke PATIO COVER STANDARD jobsite until completion, �.� (951)672.6777 29714 HAUN ROAD,MENIFEE,CA 92586 FAX(951)6793843 2/24/2014 1 WWW.CRYOFMENIFEE.US I PAGE OF2 KNEE BRACE DETAIL AT END POSTS LEDGER ATTACHMENT (REQUIRED WHEN RAFTER SPAN EXCEEDS 12 FT) DETAIL 2W f—� f—HEADER—� EDGE NAIL0 0 O B PLYW000 AT 6' 5" 0 c.AT LEDGERVCDIA BOLTS W/NUTS a 3"�- WASHERSTYPICAL ALL p NG a5' BRACED CONNECTIONS NS 9x4 BRACEIti 2xa BRACES RAFTER3" p APPROVED JOI2x LEDGER POST \\ 4x4 POST A A HANGER (MIN) I SECTION A-A Nam.. _'�/NOTCH: i.USE A CONTINUOUS AFT 2X LEDGER—SAME DEPTH 1- - AS RAFTER OR LARGER OPTION I hmmAU OPTION 2 2.SEE TABLE"D"FOR BOLTING REQUIREMENTS INVERTED HEADER DESIGN OPTION (LATTICE ONLY TWO I/2"DIA.THRU-BOLTS o (W/WASHERS), PER CONNECTION AS SHOWN o / o o 0 o FOR HEADERS OR RAFTERS- 0 a c TWO 2X MEMBERS MAY BE fto SUBSTITUTED FOR ONE 4X MEMBER. SEE TABLES "A" & J "B"FOR SPAN LIMITS A NOTE: KNEE BRACING REQUIRED WHEN RAFTER SPAN T---- EXCEEDS 12 FEET 2X FASCIA(OVERHANG)ATTACHMENT- LATTICE ONLY OPTION 1 QPTION 2 2X4 RAFTERS OR PRE-FAB.ROOF TRUSSES 2X4 LEDGER W/201 NAILS OR DIA X 4" 2X6 OR LARGER RAFTERS y LONG LAG BOLTS @32"O.C. 2X45TRUT W/(3)8tl TOENAILS SIMPSON A-35 OR �naa� FROM STRUTTO LEDGER _———, EQUAL-ANCHOR �se6i (�A�350R QIJALAN[CHOR NAILS \��` IVI 2X FASCIA 2X FASCIA ICI APPROVED JOIST HANGER APPROVED JOIST HANGER m•yM� 2X2 OR 2X4 PATIO RAFTERS PATIO RAFTERS i SEETABLF'A" o SEETABLE"A" fir•,¢ m 1� W..MAX PATIO RAPIER SPAN M PATIO RAFTER SPAN I_ OVERHANG " I'UMR'EDTO B'Fc LATTICE LIMfIEDTO B'FOR LATTICE COVER G COVER T CY WESTERN PIVERSiDE COUNIFT CODE UNIFORMITY PROGRAM NOTE: VERIFY STRUCTURAL SOUNDNESS OF ROOF CITY OF MENIFEE RAFTERS FOR DECAY OR TERMITE DAMAGE, I BUILDING DEPARTMENT AND REPLACE WITH LIKE MATERIALS AS NEEDED, AFTER CONSULTATION WITH THE PATIO COVER STANDARD BUILDING DEPARTMENT. (951)672-6777 29714 HAUN ROAD,MENIFEE,CA 92586 FAX(951)6793843 r2/24,=14 rWWW.CI7YOFMENIFEE.US PAGE20F2 PLOT/SITE PLAN REAR PROPERTY LINE City of Menifee f Building & Safety Dept. �b OCT 0 6 2017 TC2Feea�ve�R& x 4 f Z w Iv'g�r H o C TY OF MENIF E F gl s w wB ILDING AND S FETY DEPART ENT p "OP AN APPROVAL H REVIEWED BY I=07 DATE *Approval of these plans shall not be const ed to he a per it for,or an api iroval of,any violation of any provisions o edt4a� to or city t Z�1 {z reg ilations and ordinances. This set of approv lans u be kept on the job iite until completion, eft UxIj O 5+0. qTd Z Cc�r Q0.ra.C�� FRONT PROPERTY LINE Property Owners Name �sU y� ✓Li� Property Address �' �7' P� �� • �n� ; loaf T- yzr6G