Loading...
PMT17-03476 City of Menifee Permit No.: PMT17-03476 29714 HAUN RD. Type: Residential Electrical �A1,CCELJ;? MENIFEE, CA 92586 MENIFEE Date Issued: 10/10/2017 PERMIT Slte Address: 29594 CHELTON WAY, MENIFEE, CA Parcel Number: 364-370-038 92584 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 34022-3 CAMELLIA Work: 10 MODULES, 1 INVERTER,2.65kW LOT 139 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description OQt Amount I$ Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City.of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit Template.rpt Page 1 of 1 SAFETYBUILDING & PERMIT/PLAN CHECK APPLICATION . Menifee DATE:09/27/2017 PERMIT/PLAN CHECK NUMBER (7 0'2,)LA TYPE: O COMMERCIAL RESIDENTIAL 0 MULTI-FAMILY O MOBILE HOME .' POOL/SPA O SIGN SUBTYPE: - DDITION O ALTERATION DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING C}RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 2077 -2.65kW/ 10 PCS Master Solar Permit No.: PMT14-02630 PROJECTADDRESS 29594 Chelton Way ZIP 92584 ASSESSOR'S PARCEL NUMBER 364-370-038 LOT 139 TRAC OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES C NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturd@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 1 l-1(4 `j SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 09/27/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS UCENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE /3 lJ SMIP ( GREEN — PLAN CHECK FEE INVOICETOTAL OWNER BUILDER VERIFIED OYES 0 NO DRIVERS LICENSE# NOTARIZED LETTER 0 YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.650 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10 PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 1 10 PCS.1 ENPHASE I 106-60-2-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAV#2 ARRAY#3 ARRAY 44 MOD QTY 10 NA NA NA BUYER: e'[TY$F-MEN EE TILT 1 23° Ni I Ni NA' AZIMUTH 1 176° Ni I NA' NA' I City Of Menefee DATE WjrLwwj AN SA Building Dept PLAN APPPC OCT 102001' LU 7 (r' REVIEWED BY R �J ` e V e i V e d Approval of these plan;shall r Approval of,any Violet oo of a regulations and ordinal ices.Tt jobsite wtil completio I. - I I v f I 19'-9"ARRAY I 13'-2' 20'-7"FLASHING I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE METER 9 MAIN S MAIN SERVICE PANEL (VERIFIED BY BUILDER) —J L——— ————J AC COMBINER BOX (EXTERIOR-GARAGE) n tI L�—�i N NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2077 ELEVATION B-RIGHT ORIENTATION I LOT#139 CAMELLIA AT LENNAR: ORIGINAL BY:DESIREE WILLIAMS I DATE:17.8.1] 980 MONTECITO DRIVE,#302 REVIEWED BV:JIM PARKS DATE:17.8,17 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION I DW 17.8.17 10 SWAP c d f1OR1i oue DWG TITLE: PAGE#: SCALE: SITE LOCATION: ted INDIVIDUAL 4 Boulder,Bro C 8 304 29594 E,CA N WAY 3034C030304 PLOT PLAN I /Ib"=I'-0' MENIFEE,CA 30344]0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE 7 CALC UNIT DETAIL ITEM NOTE /CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH CTMAX) ASTI 2% 'C 37 INV. MODEL INVERTER SPEC IQ6-60-2-US TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN "C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(Ac) 330 TEMP,MODULE TEST(TTEST) MODULE SPEC "C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(DO) 48 TEMP,DELTA LOW(TOEETA) TYR-TTEST °C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(Ac) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.96 MOD, POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTO MODULE SPEC WATTS CDC) 238 COMPLIANCE INVERTER SPEC ULI741/IEEEI547 T Ogp, MOD. OPERATING VOLTAGE DUMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD, OPEN OCT. VOLTAGE(Vac) MODULE SPEC VOLTS(DU 38.10 INV.OTY,MAX/BRANCH OCT. INV.QTYeC CITY 16 MOD, COEFF. VOLTITEMP YCOEF) MODULE SPEC V/"C -0.114 BRANCH CCT.OUTPUT.IMAXec (IAC-INV.QTYBC) AMPS(AC) 9.60 MOD. MAX VOLTAGE(VMAXMOD) (Voc+(TD•COEF)) VOLTS(DU 41.18 INV.QUANTITY,TOTAL INV.GTYT QTY 10 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTs 0AC•INV.QTYT) AMPS(AC) 9.60 19 MOD. SHORT CCT. CURRENT DISC) MODULE SPEC AMPS(DO) 9.00 ---- MOD. MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(DO 11.25 MIN.AMPACITY REGO,PER NEC (IMAX• 1.25) AMPS(DC) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(Da) 15 strued ELECTRICAL EQUIPMENT SCHEDULE wi ionsof :1 of pprove KEY QTY MANUFACTURER MODEL NOTES TRADE 1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 10 ENPHASE 106-60-27S PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221UR8 PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR,120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER,I X 20A-2P, IX 5A-2P SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL.200A BUS BLDR.ELEC. 10 TBD II TBD B UTILITY METER. IP . 120/24OV.200A LDD U BL NDING DER. EELTBD ELECTRODE,UFER L..CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(CDU): (AMPACITY•TEMP. DERATE •FILL DERATE)VS. REO'D(IMAx) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS. REGG,OMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULThOO OCD BUS RATING AMPS 200 TYPE OERATES DERATE DERATE CA) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0. 22.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 20 PV OCPD DEVICE USED AMPS 2O B #10 CU NM-B CCU 40 0.91 JO 36.40 INTERCONNECTION CALLS: TERM 35 35 20 0.96A x IO(MODS)= 9.60A OF CURRENT C #10 CU NM-8 COU 40 0.91 L0 36.40 9.60A X 1.25= I2.OaA TERM 35 35 20 TIE-IN WITH A 20Ale 2 SPACE PV BACKFEED BREAKER CONDUCTOR SCHEDULE KEY I CONDUCTORS 1 CUI 1 TYPE LOCATION TRADE A 1-#12 ENPHASE Q CABLE,1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR B 1 3-#10, 1-#10 EGO I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 1 3-#10,1-#10 EGO I CU I NM-B(ROMEX) I INTERIOR I SOLAR NOTE:NEUTRAL NOT USED AND CAPPED 10 O 9 5 O4 5AIF O O O O OZOAl3 G GIN A B C C = II ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.650KW LOT#139 ORIGINAL BY:DESIREE WILLIAMS DATE:17.8-17 CAMELLIA AT LENNAR: REVIEWED BY:JIM PARKS DATE:I 7.8.17 980 NA.CA I92 DRIVE,#302 THE LAKES CORONA,CA 92079 REV.# BY DATE DESCRIPTION 1 Ow 17.8.17 IQ SWAP namastd SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29594 CHELTON WAY Bouker,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF Y ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH I")SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND 1 NT THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. / 9)AN ANIMAL GUARD SHALL 8E INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF LAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF LAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. p),st9tl m must be ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7).ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER, 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC.TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT}'. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.-OR EQUIVALENT,WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS.- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DESIREE WILLIAMS DATE7.8.17 CAMELLIA AT LENNAR: REVIEWED BY:JIM PARKS DATE17.8.17 9B0 NA,CA I92 DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Dw 17.8.17 IQ SWAP Vnamasr6 DWG TITLE: PAGE# I SCALE: SITE LOCATION: INDIVIDUAL 4877 Broetlwey Street PLOT PLAN 3 NTS 29594 E,CA N WAY Bo303. CO 80304 NOTES MENIFEE.CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. VxfL D it ,,:t the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX (EXTERIOR-GARAGE) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.60A I PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY:DESIREE WILLIAMS DATE:17.8.I7 CAMELLIA AT REVIEWED BY:JIM PARKS DATE:17.8.I7 CO NA,CA I92 DRIVE,#302 THE LAKES CORONA CA 92879 REV.# BY DATE DESCRIPTION I ow n.&.n to SWAP Vnamasbi0li ie L•. DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 BmaC O 8 Sheet PLOT PLAN 4 NTS MENF E.CA N WAY Bo3D3.4C080304 PLACARDS MENIFEE,LA 303.447.0300