Loading...
PMT17-03475 City of Menifee Permit No.: PMT17-03475 29714 HAUN RD. Type: Residential Electrical C ACCELA,v MENIFEE,CA 92586 MENIFEE Date Issued: 10110/2017 PERMIT Site Address: 29582 CHELTON WAY, MENIFEE, CA Parcel Number: 364-370-037 92584 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 12 MODULES, 1 INVERTER,3.18kW LOT 138 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Gott Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE:09/27/2017 PERMIT/PLAN CHECK NUMBER 1 O 5 TYPE: OCOMMERCIAL RESIDENTIAL O MULTI-FAMILY O MOBILE HOME i POOL/SPA O SIGN SUBTYPE: XAADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O: NEW O PLUMBING Q RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 2785-3.18kW/ 12 PCS Master Solar Permit No.: PMT14-02630 PROJECTADDRESS 29582 Chelton Way Zip 92584 ASSESSOR'S PARCEL NUMBER 364-370-037 LOT 138 TRA OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES O NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ S, ,3 3 l 60 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 09/27/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE SMIP GREEN PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED OYES 0 NO DRIVERS LICENSE# NOTARIZED LETTER YES G NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.180 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 1 12 PCS.1 ENPHASE I 106-60-2-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 1 ARRAY#3 ARRAY#4 City cf Menitee - T MOD OTY L 8 NA NA BUYER: ( I, Y nF INI FNIF Li' TILT 23' 23° NA- NA' Building Dept DATE: ^I'il I)I�Jn�ND AFE AZIMUTH 180° 270° NA' NA' OCT 10 20117 PLAN APPRO Received REVIEWED Approval of thew plans sh II not h approval of,any Violation fanyp mgulations and ordinances.This x jobsite until completion. 6'-7"ARRAY T-5'RUSHING i 0 Ia'-r I t I r� ag I I y N I AC DISCONNECT —— EXTERIOR-GARAGE I I _ _ UTILITY METER MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX ——— -----J O (EXTERIOR-GARAGE) ,� SOLADECK WIRE TRANSITION 80X (UNDER ARRAY) N NOTE.DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2785 ELEVATION A-LEFT ORIENTATION I LOT#138 CAMELLIA AT LENNAR: ORIGINAL BY:DESIREE WILLIAMS DATE:17.8.17 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE:17.8.17 THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION I DW 17.8.17 ICI SWAP I—:bnamastA aeu DWG TITLE: PAGE*: SCALE: SITE LOCATION: 4B Broadway Street INDIVIDUAL MENIF E.CA N WAY Boulder,C030304 PLOT PLAN I I/16"= I'-0' MENIFEE,LA 303.44Z0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV, MODEL INVERTER SPEC IQ6-60-2-US TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AQ 330 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V, NOC MAX) INVERTER SPEC VOLTS(00 48 TEMP,DELTA LOW(TDELTA) TMIN-TTEST °C -27 INV.OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(Ac) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.96 MOD. POWER SIC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(DO 238 1 COMPLIANCE INVERTER SPEC JLI741/IEEEI547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS Wd 31.30 INV. GROUNDING INVERTER SPEC ISOLATED DER MOD. OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(DG) 38.10 INV. QTY,MAX/BRANCH CCT. INV.QTYSci OTY 12 MOD.COEFF.VOLT7TEMP(COEF) MODULE SPEC V/'L -0.114 BRANCH CCT.OUTPUT, IMAXSC I (IAC'INV.QTYa0 I AMPS(Ac) 1 IL52 MOD. MAX VOLTAGE(VMAXMOD) (Voc+(To-COEF)) VOLTS(oc) 41.18 INV.QUANTITY,TOTAL I INV.QTYT I QTY 1 12 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 8.50 TOTAL SYSTEM OUTPUT, IMAXTS I(IAC'INV.QTYT) AMPS(Ad 1 11.52 MOD. SHORT CCT.CURRENT(ISO) MODULE SPEC AMPS(Dc) 9,00 MOD. MAXIMUM CURRENT(]MAX) Osc- 1.25) AMPS(oc) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX'1.25) AMPS(oc) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 strued t ELECTRICAL EQUIPMENT SCHEDULE ons ort KEY OTY MANUFACTURER MODEL NOTES TRADE proved 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 12 ENPHASE IQ6-60-2-US PV INVERTER SOLAR 3 2 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-8 AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER.I X 20A-2P. I X 5A-2P SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 10 TBD TBD UTILITY METER, IPH, 120/24OV,200A BLDR. ELEC. II TBD TBO GROUNDING ELECTRODE,UFER BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU) I (AMPACITY° TEMP.DEBATE'FILL BERATE)vs. RED (IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS vs. REO'D,(IMAX - 1,25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC- AMPACITY WIG TEMP. FILL RESULT REO'D BCD BUS RATING AMPS 200 TYPE DERATES DEBATE DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A *12 CU THWN-2 COU 30 0.76 1 1.0 22.80 11.52 ALLOWED PV PER NEC AMPS 40 TERM 25 1 25 go7 20 PV OCPD DEVICE USED AMPS 20 B #10 cu NM-B Cou 40 0.91 1.0 36.40 11sz INTERCONNECTION CALLS: TERM 35 35 14.40 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 IL52 11 52A x 12(MODS)1 11.5xA OF CURRENT ILE-I x WITH A RAGA TERM 35 35 4.40 20 TIE-IN WITH A 20A/2P L SPACE PV BACKFEEO BpEAHER CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL TYPE LOCATION TRADE A 1-#12 ENPHASE Q CABLE.1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR B 3-#Io. 1-#10 EGC I CU I NM-B(ROMEX) INTERIOR GOLAR C 1 3-#10, 1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR NOTE:NEUTRAL NOT USED AND CAPPED 10 O 11 O O 9 Q3 5 Q G O B Oj zoa/z 0A/x -IN G G G A B C C = II I I I HOOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.18OKW LOT#138 ORIGINAL BY:DESIREE WILLIAMS DATE:17:8.17 CAMELLIA AT LENNAR: REVIEWED BY:JIM PARKS DATE:17.8.17 THE LAKES CORONA,CA I92TO DRIVE,#302 CORONA,CA 92079 REV'.# BY DATE DESCRIPTION I DW 17.8.17 10 SWAP namast8 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4671 eraadway Street INDIVIDUAL 29582 CHELTON WAY Boulder,CID 803N PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- O ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS, TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(Z)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. TI 4ENT 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 5'. IO 26 GAUGE INTERLOCKING FLASHING"SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE,PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. emit(01 DIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. R(,state .ns must be 1 ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A.NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR.SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:DESIREE WILLIAMS DATE17.0.17 CAMELLIA AT LENNAR: REVIEWED BY:UIM PARKS DATE37.8.17 980 MONTECITO DRIVE,#3D2 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION I DIN 1 17.8.17 lIQSWAP namasb6 4oue DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 46]1 Broadway Street PLOT PLAN 3 NTS 295B2 E,CA N WAY Boulder, 7. 80304 NOTES MENIFEE,CA 303.44].0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. nR 07 ty �:n the PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX (EXTERIOR-GARAGE) SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.52A I PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA AT ORIGINAL BY:DESIREE WILLIAMS DATE17.8.1 980 M 7 O:NTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE17.8.17 80 O THE LAKES CORONA,CA 92879 REV.* BY DATE I DESCRIPTION •� I DW 17.0.17 IQ SWAP to namast i SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 451 Broatlway Street INDIVIDUAL 29582 CHELTON WAY BO3034CO 80304 PLOT PLAN 4 NTS PLACARDS MENIFEE,CA 03. 47.0300