PMT17-03474 City of Menifee Permit No.: PMT17-03474
c 29714 HAUN RD. Type: Residential Electrical
ACCEL/k? MENIFEE, CA 92586
MENIFEE Date Issued: 10/10/2017
PERMIT
Site Address: 29570 CHELTON WAY, MENIFEE,CA Parcel Number: 364-370-036
92584 Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 10 MODULES, 1 INVERTER, 2.65kW
LOT 137
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number: 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description ON Amount isl
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pernit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
Menifee
DATE:09/27/2017 PERMIT/PLAN CHECK NUMBER ` \ 11-j -D-3
TYPE: OCOMMERCIAL kRESIDENTIAL O MULTI-FAMILY a MOBILE HOME O POOL/SPA SIGN
SUBTYPE: ADDITION O ALTERATION O DEMOLITION 0 ELECTRICAL MECHANICAL
- NEW O PLUMBING 0 RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit- Plan 2077 -2.65kW/ 10 PCS
Master Solar Permit No.: PMT14-02630
PROJECTADDRESS 29570 Chelton Way ZIP 92584
ASSESSOR'S PARCEL NUMBER 364-370-036 LOT 137 TRACT
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES CJ NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 6 q q S L SQ FT
APPLICANT'S SIGNATURE DATE 09/27/2017
DEPARTMENT DISTRIBUTION / CITY OF MENIFEE BUSINESS UCENSE NUMBER
BUILDING PANNING ENGINEERING FIRE ACDCCEPTED BY: �l
PERMIT FEE a •I..C, SMIP + GREEN
PLAN CHECK FEE INVOICE TOTAL W O
OWNER BUILDER VERIFIED OYES --.:C NO DRIVERS LICENSE# 0141 NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 925§#H54- #qw
www.cityofmenifee.us
Building & Safety Dept.
SEP 2 9 201?
Received
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM CITY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 12.650KW I I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE IO PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER:_
INVERTER 1 10 PCSJ ENPHASE I 106-60-2-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION CITY OF MENIF E
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 10 NA NA NA BUYER: 1WILDING AND SAFF
TILT 23' NA* NA' NA'
AZIMUTH 186° NA' NA' NA' DATE: PI AU AODD
City of Menifee
Building Dept
kI:ViI:WEDB
OCT
10 g L011 Approval of these plans s all nol I
approval of,any violation ofany F
Received regulations and ordinance This
johsite until completion.
F--_ - _-_ - - ----- - - - ---- - ----
I I
1 I
I
I
19'-9'ARRAY
20'-7"FLASHING
_ SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT ,
EXTERIOR-GARAGE
I' I UTILITY METER&
MAIN SERVICE PANEL
MONO
i L___ (VERIFIED BY BUILDER)
AC COMBINER BOX
tttt 1 (EXTERIOR-GARAGE)
DIM
r
N
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2077 ELEVATION C-RIGHT
ORIENTATION I LOT#137
LENNAR: ORIGINAL BY:DESIREE WILLIAMS I DATE:17.8.17
CAMELLIA AT 980 I DRIVE,#302 REVIEWED BY:JIM PARKS DATEJ7.8.17'
THE LAKES CORONA,
A,C LA A 92879 REV.# BY DATE DESCRIPTION
I OW 17.8.17 10 SWAP' namasC6
ioLaa
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway5treet
INDIVIDUAL 29570 CHELTON WAY Boulder,CO W304
PLOT PLAN 1/16'=I'-0' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE /CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC 106-60-2-US
TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 330
TEMP MODULE TEST(TTEST) MODULE SPEC 'C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(DC) 48
TEMP,DELTA LOW(TOELTA) TMIN-TTEST °C -27 INV. OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AO 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV, OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.96
MOD. POWER STC.(P) MODULE SPEC WATTS WC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE pAR
MOD. POWER PTC MODULE SPEC WATTS(DO) 238 COMPLIANCE INVERTER SPEC ULI741/IEEEI547�'
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD.OPEN CCT.VOLTAGE(VDU MODULE SPEC VOLTS(oc) 38.10 INV.CITY,MAX BRANCH CCT. INV.QT"B QTY 10 •
MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/'C -0.114 BRANCH CCT. 7 OUTPUT,IMAXBC I UAC'INV.OTY8U AMPS(AC) 1 9.60.
MOD. MAX VOLTAGE (VMAXMOD) (Voc t(TD'COEF)) VOLTS(Dc) 41.18 INV.QUANTITY,TOTAL INV.QTYT QTV I 10
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC'INV.QTYT) AMPS(AC) 1 9.60 —
MOD. SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(DU 9.00
MOD. MAXIMUM CURRENT(IMAX) USE- 1.25) AMPS(OO) 11.25
MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(DO 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DU 15 .I,F led to be
u.iun of the t
ELECTRICAL EQUIPMENT SCHEDULE Rpp oved ph
KEY CITY MANUFACTURER MODEL NOTES TRADE
1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 10 ENPHASE 1Q6-60-21)S PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR
5 1 ENPHASE ID ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR
6 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR
7 1 ENPHASE TBD PV BREAKER, I X 20A-2P,I X 5A-2P SOLAR
8 1 CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P,RATING MAY VARY SOLAR
9 1 TBD TBO SERVICE PANEL 200A BUS BLDR. ELEC.
10 TBD TBD UTILITY METER, IPH, 120/24OV,200A BLDR ELEC.
II TB TBO GROUNDING ELECTRODE,UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): (AMPACITY' TEMP.BERATE 'FILL DEBATE)vs. REO'D(MAX) ITEM UNIT PgNEL
2)TERMINALS(TERM). AMPACITY AT TERMINALS. VS. REGO.(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REG D OCO BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 1 30 0.76 W35
9.60 ALLOWED PV PER NEC AMPS 40
TERM 25 12.00 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B COU 40 0.91 9.60 INTERCONNECTION CALCS:
TERM 35 12.00 20 0.96A X TO(MODS)= 9.60A OF CURRENT
C #10 CU NM-B COU 40 0.91 9.60 9.60A X 1.25= I2.00A
TERM 35 12.00 20 TIE-IN WITH A 20A(2P 2 SPACE PV BACKFEED BREAKER
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS 1 CU/AL 1 TYPE I LOCATION I TRADE
A I I-#12 ENPHASE Q CABLE, 1-#6G,FREE AIR I CU I UL3003.DG CABLE ARRAY SOLAR
B 3-#I0, I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
C 3-#10. 1-#10 EGC ICU I NM-B(ROMEX) I INTERIOR I SOLAR
NOTE:NEUTRAL NOT USED AM CAPPED 0
O
9
5 O4
5A/2P
O O � 20
O
0P/2P
r �N
G G
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.650KW
LOT# 137
ORIGINAL BY:DESIREE WILLIAMS DATE:17.8.17
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:I7.B.17
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
DW 17.8.17 IO SWAP namasl78
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
treet
INDIVIDUAL 4B71lder,C a8 304
PLOT PLAN 2 NTS 29570 E,CA N WAY Boulder, 7030304
ELECTRICAL MENIFEE,CA 303.44],0300
INSTALLATION NOTES:
SOLAR CONTRACTOR-
I)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED,
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
APRIL 2016 EDITION.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES-(2")BEYOND ��
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY
10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE C
TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. wtmil oq Ol
14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE,aI S e Ot city
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. Y
Trost kept on
ELECTRICAL NOTES
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTU,
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 9WC RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE ULI703,(EC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT J'.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE."OR EQUIVALENT,WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110,26.
ORIGINAL BY:DESIREE WILLIAMS DATELI.B.IT
CAMELLIA AT ENNAR;
980 MONTECITO DRIVE,.#302 REVIEWED BY:JIM PARKS I DATE]7.8.17
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
DW FL8.I7 IQ SWAP 16 n iOLAiamasbe
DWG TITLE: PAGE*: SCALE: SITE LOCATION: 4571 Bm"ay Stwt
INDIVIDUAL 29570 CHELTON WAY Boultler,C080304
PLOT PLAN 3 NTS MENIFEE,CA
NOTES 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER e
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
AC COMBINER BOX
(EXTERIOR-GARAGE)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 9.60A
I PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:OESIREE WILLIAMS DATE:17.8.17
CAMELLIA AT LENNAR: REVIEWED BY:JIM PARKS DATE:17.8.17
CO NA.CA I92 DRIVE,#3O2
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
I Dw 1 17.8.17 1 ID SWAP ;-pnamasb6
SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
4Bo Broadway Street
INDIVIDUAL 29570IEE.C TON WAY Boulder, 80304
PLOT PLAN 4 NTS MENIFEE,CA 303.477.0300
PLACARDS