Loading...
PMT17-03472 City of Menifee Permit No.: PMT17-03472 29714 HAUN RD. CACCELA? MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 1 011 912 01 7 PERMIT Site Address: 29045 BOTANICAL CIR,MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 1 INVERTER,2.24kW LOT 70 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number: 728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description 9ti Amount($I Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION v �V, "Wenifee DATE:09/25/2017 PERMIT/PLAN CHECK NUMBER TYPE: O COMMERCIAL '. ESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: DDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O PLUMBING C) RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 1678 -2.24 kW 17 PCS Master Solar Permit No.: PMT17-00129 PROJECTADDRESS 29045 Botanical Cir ZIP 92584 ASSESSOR'S PARCEL NUMBER TBID LOT 70 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito DR., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? )YES G NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8017.20 SO FT L SQ FT APPLICANT'S SIGNATURE 09/25/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE SMIP GREEN PLAN AN CHECK FEE INVOICE ETOTAL � 4. (0O OWNERBUILDER VERIFIED DYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES 0 NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92S86 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 CITY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.240 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 7 PCS.1 LG I LG320EIK-A5(3207) BUYER: INVERTER 1 7 PCS.1 ENPHASE I O6PLUS-72-2-US ROOF TYPE I TILE W7 COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY IN ARRAY#2 I ARRAY#3 ARRAY#4 MOD CITY 7 NA NA NA BUYER: --- TILT 23' NA' NA' NA' AZIMUTH 250- NA' NA' NA' DATE: 3' s-6" City Me p Building Dept - OCT 0 5 2017 V Y= Received r SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE S, � � E MAIrV E Q I (VERnRUM AN SA -TY DEPART\ . PLAN APP V AC COMBINER BOX REVIEWED BY DATE Approval of these plans shall not be conAmcd to be a permit for,or an Proval Of,any violation Of my pn,n.mns of the federal,state or city 'loons and ordinances.This set of approved plans must be kept on the -ntil completion. NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1678 ELEVATION A-LEFT ORIENTATION 3 LOT#70 LENNAR: ORIGINAL BY:ANGELA BURKE DATE:09:20.17 HERITAGE HEIGHTS 2603 CAMINO RAMON#525 REVIEWED BY:ARTHUR HICKS I DATE:09.21.17 SAN RAMON,CA 94583 REV.# BY DATE DESCRIPTION ;Pnamasb6 ante• DWG TITLE: PAGE#: SCALE: SITE LOCATION' 4571 Broadway Street INDIVIDUAL 29045 BOTANICAL CIRCLE BoWd.r,der,CO 80304 PLOT PLAN I/16'=I'-0" MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 7 LG LG320EIK-A5(32OW) PV MODULE SOLAR 2 7 ENPHASE 106PLUS-72-2-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER, I X 2OA-2P, I X 5A-IP SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 10 1 TBD TBD UTILITY METER, IPH, 1201240V,200A BLDR. ELEC. II 1 TBD T8D GROUNDING ELECTRODE,UFER BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM MAMPS PANEL LOCATION MENIFEE,CA PANEL HER. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC 40 TEMP,DELTA LOW(TDELTA) THIN-TESST °C -27 PV OCPD DEVICE USED 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC. LG320NIK-A5(320W) 1.17A X]MODS)= 11.19A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(Dc) 320 9.19A X 1.25= 10.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 20A/2r 2 SPACE Pv SACFFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE /RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 /IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. QTY BC QTY 7 BRANCH CIRCUIT OUTPUT, IMAXBC (IAC-MOD.QTY BO) AMPS(AC) 8.19 AC MODULE QUANTITY,TOTAL MOD. OTY T UTY 7 TOTAL SYSTEM OUTPUT IMAXTS OAC'MOD. OTY T) AMPS(AC) 8.19 CONDUCTOR SIZING CALCULATIONS I)CONDITION OF USE(COO) (AMPACITY ° TEMP. DERATE ° FILL DERATE)VS. REQ'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. Vs. RED'0,(IMAX - 1 251 KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REO'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A t#12CUTHWN-2 COO 30 .76 1.0 22AO 8.1TERM 25 25B NM-B COU 40 .91036.4019TERM 35 35 1 .24 20 C NM-R COU 40 .91 1.0 36.40 8.19 TERM 35 35 10.24 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU7AL TYPE LOCATION TRADE 46 �0 A -#12 ENPHASE Q CABLE, 1-#6G,FREE AIR ICU TC-ER ARRAY SOLAR B 3-#10, 1-#10 EGG CU NM-B(ROMEX) INTERIOR SOLARC 3-#IQ 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR5 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.24o KW LOT#70 ORIGINAL SY:ANGELA BURKE DATE:09.20.1 LENNAR: 7 HERITAGE HEIGHTS REVIEWED BY:ARTHUR HICKS DATE09.21.17 2603 CAMINO RAMON#525 SAN RAMON,CA 94583 REV.# BY DATE DESCRIPTION namasGe muv DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4571 ldw,Bra GO 8 304 PLOT PLAN 2 NTS 29045 BOTANICAL CIRCLE BOWOer,CO 80004 ELECTRICAL MENIFEE,CA 303.447.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER.MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH Q')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3". IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 07 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS.USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703. IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:ANGELA BURKE DATED9.20.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATE99.21.17 2603 CAMINO RAMON#525 SAN RAMON.CA 94583 REV.# BY DATE DESCRIPTION ISM masbA. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Snot INDIVIDUAL PLOT PLAN 3 NTS 29045 BOTANICAL CIRCLE Boulder, 7. 3004 3 04 NOTES MENIFEE,CA 3034g7.000 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 9 MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER.BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:ANGELA BURKE DATE.09.20.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATEA9.21.17 SAN AN GAMIN, RAMON#525 RAMON,CA 94583 REV.# BY DATE DESCRIPTION S:tmamast;6 SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4Bo &o.CO8Street INDIVIDUAL MENIF BOTANICAL CIRCLE BONtler,C030304 PLOT PLAN 4 MS MENIFEE,CA 303.4A7.0300 PLACARDS