Loading...
PMT17-03467 City of Menifee Permit No.: PMT17-03467 29714 HAUN RD. Type: Residential Electrical A'' MENIFEE, CA 92586 MENIFEE Date Issued: 10/19/2017 PERMIT Site Address: 29056 BOTANICAL CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 8 MODULES, 1 INVERTER,2.56kW LOT 65 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtv Amount ISI Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 BUILDING SAFETY PERMIT/PLAN APPLICATION A Menifee DATE:09/25/2017 ,,// PERMIT/PLAN CHECK NUMBER 1 1 n- TYPE: 0 COMMERCIAL ,- ESIDENTIAL 0 MULTI-FAMILY 0 MOBILE HOME ') POOL/SPA G SIGN SUBTYPE: /<ADDITION 0 ALTERATION 0 DEMOLITION n ELECTRICAL 0 MECHANICAL O NEW O PLUMBING '> RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 2131 - 2.56 kW /8 PCS Master Solar Permit No.: PMT17-00129 PROJECTADDRESS 29056 Botanical Cir Zip 92584 ASSESSOR'S PARCEL NUMBER TBD LOT 65 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito DR., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNERBUILDER? OYES ONO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8017.20 S L SQ FT APPLICANT'S SIGNATURE DATE 09/25/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER B BUILDING PLANNING ENGINEERING FIRE ACCEPTED Y: PERMIT FEE I 0AL00SMIP Ol GREEN PLAN CHECK FEE INVOICE TOTAL v OWNER BUILDER VERIFIED ^.YES - NO DRIVERS LICENSE# NOTARIZED LETTER YES L? NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.citycfmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM KPCS.1 R. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE LG320EIK-A5 MDR) BUYER: INVERTERPHASE I 106PLUS-72-2-US ROOF TYPE I TILE Wf COMPOSITE SHINGLE UNDER ARRAY DATE: - SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD CITY 1 8 NA NA NA BUYER: — - - - - TILT 23° NA° NA° NA' AZIMUTH 1 252 RA. NI NA- city City of Meniiee Building Dept 5'-6" ,3' OCT 0 5 2017 Received V �aa SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT ^ CITY OF ME IFE1" TNTNT EXTERIOR-GARAGE V BUILDING A D S , UTILITY METER 8 MAIN SERVICE PANEL PLAN APPRIC j lop (VERIFIED BY BUILDER) 4g!! t AC COMBINER BOX REVIEWED BY D,�I Approval of these plans shall not Inc wretrucd to be a pe s or an V o approval of,any violation of any prow uiuns ot'Ihe Cederal, r city e 1 the rrgulanar,;:u ul ordinances.THIS scl of approved plans to p pbsltc until comPlcllon. NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ^, PLAN 2131 ELEVATION C-RIGHT ®'V ORIENTATION I LOT#65 LENNAR: ORIGINAL BY:ANGELA BURKE DATE:09.20.17 HERITAGE HEIGHTS 2603 CAMINO RAMON#525 REVIEWED BY:ARTHUR HICKS I DATE:09.21.17 SAN RAMON,CA 94593 REV.# BY DATE DESCRIPTION �Pmamast;6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29056 BOTANICAL CIRCLE BmIdw.CO 80304 PLOT PLAN 1 I/16"=1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 8 LG LG320EIK-A5(32OW) PV MODULE SOLAR 2 8 ENPHASE I06PLUS-72-2-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER, I X 20A-2P. I X 5A-IP SOLAR B I CUTLER-HAMMER TRIG PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. IO TBD TBp UTILITY METER, IPH,120/24OV,200A BLDR. EL EC. 11 TBD TBD GROUNDING ELECTRODE,UFER BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL HER. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST •C -27 PV COED DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(327W) 1.17A X e(MODS)= 9.36A OF CURRENT MOD. POWER STC OF) AC MODULE SPEC: WATTS(DO 320 9.36A X 1.25= I130A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC H2(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741I IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY.MAX.PER BRANCH CIRCUIT MOD. OTY BG OTY 8 BRANCH CIRCUIT OUTPUT,IMAXBC 0AC'MOD.OTY BO) AMPS(AC 9.36 AC MODULE QUANTITY,TOTAL MOD. QTY T QTY 8 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD. OTY T) AMPS(AC) 1 9.36 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(LOU) (AMPACITY • TEMP.DERATE - FILL DEBATE)VS.REG'D(TMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vti. REG 0(TMAX' 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD TYPE DERATES DEBATE DEBATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 .76 1 1.0 22.80 9.36 TERM 25 1 25 11.70 20 B #10 CU NM-B COU 40 .91 I:0 36.40 9.36 TERM 35 35 11.70 20 C #10 CU L0 NMI COU 40 .91 36.40 9.36 TERM 35 35 11.70 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CORAL TYPE LOCATION 1 TRADE A 1-#12 ENPHASE Q CABLE, -#6G,FREE AIR I CU TC-ER ARRAY I SOLAR B 3410, 1-#10 EGG CU I NM-B(ROMEX) I INTERIOR I SOLAR 10 C 3410, I-#10 EGG CU NM-B(ROMEX) INTERIOR I SOLAR O 5 44 snnP zaO 0 xonr �_ N A B C C = II ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.56OKW LOT#65 ORIGINAL BY:ANGELA BURKE 1 DATE:09.20.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS I DATE:09.21.17 2603 CAMINO RAMON#525 SAN RAMON,CA 94583 REV.# BY DATE DESCRIPTION namasbe lOLA4 DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29056 BOTANICAL CIRCLE BO303.4 7030304 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 03.44 .000 INSTALLATION NOTES: SOLAR CONTRACTOR- I)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH({')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8).UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3". IU 26 GAUGE INTERLOCKING FLASHING"SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT OH)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 6)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS, 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAWLIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J''. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19) INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:ANGELA BURKE DATEO9.20.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATE09.21.17 2603 CAMINO RAMON#525 SAN RAMON,CA94583 REV.# BY DATE DESCRIPTION Vnamcist6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway GO8Street PLOT PLAN 3 NTS 29056 BOTANICAL CIRCLE Boulder, 014 7, 0304 NOTES MENIFEE,GA 03.4470300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL ERIFIED BY BUILDER) "":AC�—z COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 9.36A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:ANGELA BURKE DATE:09.20.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:ARTHUR HICKS DATEo09.21.17 SAN AMOCAMINO RA945 #525 SAN RAMON,CA 94583 REV.# BY DATE DESCRIPTION Vnicimasri§ mva DWG TITLE: PAGE#: SCALE: SITE LOCATION- 4Bo Ber,GO6dway 3D4 INDIVIDUAL MENIF BOTANICAL CIRCLE Boulder, 7030004 PLOT PLAN 4 NTS MENIFEE,CA 303:447.0300 PLACARDS