PMT17-03464 City of Menifee Permit No.: PMT17-03464 29714 HAUN RD. SnCCEL/? MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 10/06/2017 PERMIT Site Address: 28626 FIELDGRASS ST,MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 7 MODULES, 1 INVERTER 2.24kW LOT 85 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description 99t Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION �L,Menifee DATE:09/25/2017 PERMIT/PLAN CHECK NUMBER TYPE: O COMMERCIAL RESIDENTIAL •O MULTI-FAMILY 0MOBILEHOME POOL/SPA O SIGN SUBTYPE: 'ADDITION OALTERATION O%DEMOLITION C ELECTRICAL I.% MECHANICAL C NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 1874 - 2.24 kW/7 PCS Master Solar Permit No.: PMT17-00129 PROJECTADDRESS 28626 F►eUdrgSS sA' . ZIP 92584 ASSESSOR'S PARCEL NUMBER TBD LOT 85 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito DR., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES "NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturd@iennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8017.20 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 09/25/2017 crrvsrA v DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMIT FEE G' I SMIP i GREEN ' PLAN CHECK FEE INVOICE TOTAL (00 OWNER BUILDER VERIFIED OYES O NO DRIVERS LICENSE# NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.citypfimenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 OTY MER, MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.24OKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE I 7PCS.1 LG I LG3ZOEIK-A5(32OW) BUYER: INVERTER I 7PCS.1 ENPHASE I 106PLU5-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD CITY 7 NA NA NA BUYER TI : LT I8' NA* NA' NA' AZIMUTH 178- NA' NA' NA' DATE: City of Menifee Building Dept OCT 0 5 2017 3'It S'-6' Received �Z V SOLADECK x N Q ANS ITIO WIRE TRANSITION BOX '�Y (UNDER ARRAY) CITY OF MENIFEF, u'1I.DING AND SAFETY r EPARTMENT 1%4 A"PROVA I. PV AC DISCONNECT EXTERIOR-GARAGE ' UTILITY METER e D E MAIN SERVICE PANEL (MAIN IEO BY BUILDER) _�.nlc o a .n of the fedeml,31 of city AC COMBINER BOX ,iron ed PI ins must he kept on the p.,.,, - a NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1874 ELEVATION A-RIGHT Z ORIENTATION 2 LOT#05 ORIGINAL BY:CHRISTINE MARTINI DATE:I7.07.11 HERITAGE HEIGHTS LENNAR: 980 I DRIVE,#302 REVIEWED BY:JIM PARKS DATE:17.07.11 CORONNA,A,C CA A 92879 REV.# BY DATE DESCRIPTION namost€ tOLAR DWG TITLE: PAGE AN I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 28626 FIELDGRASS ST Boulder,CO 80304 PLOT PLAN I/16'= 1'-0' MENIFEE,CA 303.4470300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 7 LG LG320NIK-A5(32OW) PV MODULE SOLAR 2 7 ENPHASE 106PLUS-72-ACM-US PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 ENPHASE 10 ENVOY ENV-IGAMI-240 PV DATA MONITOR,12GV SOLAR 6 1 ENPHASE X-IG-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TIED PV BREAKER.I X 20A-2P, I X 5A-IF SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER, I X 25A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 0 TBD TBD UTILITY METER, IPH, 120/24OV,200A BLDR. ELEC. 1 II THE TBD GROUNDING ELECTRODE UFER 1 BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL HER. CUTLER-HAMMER TEMP,AMBIENT HIGH(THAR) ASHRAE 2% 'C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) TMw-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD, MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD.PART NUMBER AC MODULE SPEC LG320NIK-A5(320W) I.17A x 7(MODS)= 9.19A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(Dc) 320 0.I9A x 1.26= I0.24A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 2OA/2P Z SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(AC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC ULI741/ IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPO AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. QTY Bc OTY 7 BRANCH CIRCUIT OUTPUT, 1MAXBC (IAC-MOD.QIFY 8C) AMPS(AQ 8.19 AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 7 TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD. OTY T) AMPS(AC) 18.19 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY • TEMP. DERATE -FILL DERATE)VS. RED(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.in.RE'D,(IMAX ° 1.25) KEY SIZE CU/AL INSULATION CALC' AMPACITY W/0 TEMP. FILL RESULT REO'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 .7 11.0 22.80 8J9 TERM 25 25 10.24 20 B #10 CU NM-B COU 40 .91 1.0 36.40 8.19 TERM 35 35 10.24 20 C #10 CU NM-B COU 40 :91 I.0 36.40 8.19 TERM 35 35 10.24 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CUI41- TYPE LOCATION TRADE A 1-#12 ENPHASE O CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10,L#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 1B C 3-410,I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR M © 9 S SA/IF 8 c) 0 0 oO 0 ¢GA/2P - N T17tT , 1 A B c c 11 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.240KW LOT#85 ORIGINAL BY:CHRISTINE MARTINI I DATE: LENNAR: 17.G7.11 HERITAGE HEIGHTS REVIEWED BYJIM PARKS I DAT217.07.0 980 MONTECITO DRIVE,#302 � CORONA,CA 92879 REV.# BY DATE DESCRIPTION � namasC6 SOLAR DWG TITLE: PAGE#: SCALE SITE LOCATION: INDIVIDUAL 4B71 Boulder,D aY Street PLOT PLAN 2 NTS 28626 FIELOGRAGS ST 203A4 O 80304 MENIFEE.CA 30Sg47.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- 0 ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.G. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECN WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH($)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. II)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION, IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(19 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM:ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.IZ OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS: 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W1 ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 15)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15).PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:CHRISTINE MARTINI DATE17.07.11 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE17.07.11 960 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasG6 totes DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 28626 FIELDGRASS ST Boulder,GO 80304 PLOT PLAN 3 NITS MENIFEE,CA 303.4470300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 19A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI DATE.17.07.11 HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE17.07.11 CORONA,CA 92879 REV.# 8Y DATE I DESCRIPTION Vnamasb6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 28626 PIELDGRASS ST Bo C080304 PLOT PLAN 4 NTS MENIFNIFEE,CA 303.303.497.0300 PLACARDS