PMT17-03455 City of Menifee Permit No.: PMT17-03455 29714 HAUN RD. Type: Residential Electrical <ACCELA� MENIFEE,CA 92586 MENIFEE Date Issued: 1 010 612 01 7 PERMIT Site Address: 29112 BOTANICAL CIR, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 10 MODULES, 1 INVERTER,3.20Kw LOT 62 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Olyt Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 PERMIT/PLANBUILDING & SAFETY APPLICATION ��Menifee DATE:09/25/2017 PERMIT/PLAN CHECK NUMBER TYPE: COMMERCIAL 'RESIDENTIAL �, MULTI-FAMILY O MOBILE HOME POOL/SPA O SIGN SUBTYPE: ;WI(DDITION C ALTERATION 0 DEMOLITION 0 ELECTRICAL O MECHANICAL NEW O PLUMBING 0 RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit - Plan 2686 - 3.20 kW/ 10 PCS Master Solar Permit No.: PMT17-00129 PROJECTADDRESS 29112 Botanical Cir ZIP 92584 ASSESSOR'S PARCEL NUMBER TBD LOT 62 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr. Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito DR., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACrOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? O YES ONO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturrl@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8017.20 SO FT L SO FT APPLICANT'S SIGNATURE DATE 09/25/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY: PERMITFEE Oar SMIP — GREEN 1� PLAN CHECK FEE INVOICETOTAL OWNER BUILDER VERIFIED --:= YES NO DRIVERS LICENSE# NOTARIZED LETTER 4 YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityCfmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 10TY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.200 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 IO PCS.1 LG I LG320EIK-A5(320W) BUYER: INVERTER 1 IO PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE— SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 10 NA NA NA BUYER: TILT 23' NA' I NA- NA' AZIMUTH 1 272° 1 NA' I NA- INA` DATE: City of Menifee Building Dept CT 0 5 2017 Re eived 1a P LL a� �r SOLADECK WIRE TRANSITION BOX / _ (UNDER ARRAY) Y\/ CITY ENIFEE BAIL AND SAFETY DEP TMENT O PV AC DISCONNECT MAI` PF VAL EXTERIOR-GARAGE UTILITY METER& 0 1=11 ' MAIN SERVICE PANEL RE VII' D BY (VERIFIED BY BUILDER) v DA E AC COMBINER BOX App,uca - ese plans shall not construed t be a permit fo or an eppu+�a y Holed i of iv revisions oft federal,state r city rcgulaUt <a ordinances. et of approved plans must be ept on the jobsite a mpletion. NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 2620 ELEVATION C-LEFT ORIENTATION 1 LOT#62 ORIGINAL BY:CHRISTINE MARTINI DATE:I7.07.11 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIMPARKS DATEu.G7J1 990 MONTECITO DRIVE,#30& CORONA,CA 92879 REV.# BY DATE I DESCRIPTION �Rnamasri§ SOIA� DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571&oO 8 St INDIVIDUAL 29112 BOTANICAL CIR Bo ,G reet 7030004 PLOT PLAN I I/15"=I'-0" MENIFEE,CA 303.4 303.4 47.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES I TRADE 1 10 LG LG320NIK-A5(320W) PV MODULE SOLAR 2 10 ENPHASE IQ6PLUS-72-ACM-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER,I X 20A-2P, I X 5A-IP SOLAR 8 I CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 10 1 TBD TBD UTILITY METER, IPH, 1201240V.200A BLDR. ELEC. 11 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE /CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR. MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(32OW) L17A X IO(MODS)= II.70A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS Inc) 320 II.70A x 1.25= I4.63A PEAK OUTPUT POWER STC(P) AC MODULE SPEC. WATTS(AC) 290 1 TIE-IN WITH A ZOAl2F 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60 159.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 /IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY, MAX PER BRANCH CIRCUIT MOD. QTY Be OTY 10 BRANCH CIRCUIT OUTPUT, IMAXBC OAC-MOD.QTY Be) AMPS(AC) 11.70 AC MODULE QUANTITY, TOTAL MOD. CITY T QTY 10 TOTAL SYSTEM OUTPUT IMAXTs (IAC•MOD.OTY T) AMPS(AC) 11.70 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COU): (AMPACITY ° TEMP. DERATE •FILL DERATE)VS.REO'D(IMAX) 2)TERMINALS(TERM)-. AMPACITY AT TERMINALS. Vs.REO'D.(IMAX.° 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #I2 CU THWN-2 COU 30 .76 1.0 22.80 11.70 TERM 25 25 14.63 20 B 410 CU NM-8 COU 40 .91 1.0 36.40 11.70 TERM 35 35 14.63 20 C #10 LU NH-B COU 40 .91 1.0 36.40 IL70 TERM 35 35 14.63 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENPHASE 0 CABLE,I-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10, 1-#10 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR 10 C 3-#I0, 1-#I0 EGO I CU I NM-3(ROMEX) INTERIOR I SOLAR O M 9 5 m Q SA/IP O O O zOnreP N G 6 G A e c T= B ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.20OKW LOT#62 ORIGINAL BY:CHRISTINE MARTINI DATE 17.07.II HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATEdT07.11 CORONA,A,C CAA 980 NI 2 DRIVE,#302 92879 REV.# BY DATE DESCRIPTION namasb6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 B.cWay SI INDIVIDUAL PLOT PLAN 2 NTS 29112 BOTANICAL CIR Boulder,CO 80309 ELECTRICAL MENIFEE,CA 203.,VIT0000 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE PORTION OF ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION APRIL 2016 EDITION. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH Q')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 0)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 10)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF Y. IU 26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 12)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 13)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN.FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 14)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED.AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W7 ENPHASE MICRO-INVERTER SYSTEM. 10 MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS, 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING./PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT r. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. : ORIGINAL BY-CHRISTINE MARTINI DATE37.07.1 LENNAR 1 HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE17.07.11 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION v amastAR ,e,.. DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Street PLOT PLAN 3 NTS 29112 BOTANICAL CIR Bauder,CO W304 NOTES MENIFEE,CA 303447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. sTAGEcn TRRANSITIONN BOX (LwOER ARRAYI PV AC.DISCONNECT EXTERIOR-GARAGE IRILITY METER B AIN M SERVICE PANEL (VERIFIED BY WILDER) d- AS COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 11.70A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:CHRISTINE MARTINI DATE17.07.11 LENNAR: HERITAGE HEIGHTS REVIEWED BY:JIM PARKS I DATE17.07.11 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbB vouv DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4Bo BouldeBroadr, 8 304 PLOTtroot INDIVIDUAL 29112 BOTANICAL CIR Boulder,COB0304 PLOT PLAN 4 NTS MENIFEE,CA PLACARDS 303.447.0300