Loading...
PMT17-03450 City of Menifee Permit No.: PMT17-03450 29714 HAUN RD. �1CCELA? MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 1 010 612 01 7 PERMIT Site Address: 28668 FIELDGRASS ST, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 8 MODULES,8 INVERTERS,2.12kw LOT 83 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qhr Amounti$I Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permd_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION ,Menifee DATE:09/27/2017 PERMIT/PLAN CHECK NUMBER Y 1" `�Trj lO:�—>`T TYPE: 0 COMMERCIAL XRESIDENTIAL 0 MULTI-FAMILY 0 MOBILE HOME C POOL/SPA =>SIGN SUBTYPE: DDITION C ALTERATION O DEMOLITION C ELECTRICAL C MECHANICAL O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 1874 - 2.12kW/8PCS Master Solar Permit No.: PMT17-00129 PROJECTADDREss 28668 Fieldgrass St. ZIP 92584 ASSESSOR'S PARCEL NUMBER TBD LOT 83 TRACr31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? C YES ONO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8017.20 SQ FT T' APPLICANT'S SIGNATURE DATE 09/27/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER ACCEPTED BY: BUILDING PLANNING ENGINEERING FIRE PERMIT FEE SMIP GREEN FFN CHECK FEE INVOICE TOTAL R BUILDER VERIFIED DYES 0 NO DRIVERS LICENSE# NOTARIZED LETTER C YES 0 NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY HER. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.120 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8 PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER:__ INVERTER 1 8 PCSI ENPHASE I 106-60-2-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOO CITY 8 NA NA NA BUYER: - - _ - - TILT 23' NA' NA° NA' AZIMUTH 180- NA° NA° NA' DATE: COPY OF MENIFEE BUILDING AND SAFETY DEPARTMENT ' 5'-5• PLAN APPROVA REVIEWED BY IDU X DA i I Approval of these plans shall not be construe in be a permit for,or an approval of,any violation of any provisions o the federal,state or city regulations and ordinances.This set of appm plena must be kept on th jobsile until completion. I I a� I as f Y I I 1 1 1 I SOLADECK WIRE TRANSITION BOX CUNDER ARRAY) AC COMBINER BOX PV AC DISCONNECT EXTERIOR-GARAGE 1 UTILITY METER& MAIN SERVICE PANEL (VERIFIED BV BUILDER)' NOTE:DIMENSIONS ARE:SHOWN IN PLANE OF ROOF PLAN 1874 ELEVATION C-RIGHT Z ORIENTATION 2 LOT#83 LENNAR: ORIGINAL BY:SHAUN MARUNA DATE:17.05.17 HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE:17.05.17 CO NA,CA I92 DRIVE,#302 CORONA,GA 92879 REV.# BV DATE DESCRIPTION �Rnamasuidi SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 28668 FIELDGRASS ST Boulder,DO 80304 PLOT PLAN 1116"=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION FONTANA,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(THAX) ASHRAE 2% °C 36 INV. MODEL INVERTER SPEC 106-60-2-US TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -1 INV. MAX POWER,(WAD MAX) INVERTER SPEC WATTS(AC) 330 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS WC) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST 'C -26 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT. [AC INVERTER SPEC AMPS(AC) 0.96 MOD. POWER STC(P) MODULE SPEC WATTS CDC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD, POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC ULI741JIEEEI547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS CDC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD, OPEN CCT.VOLTAGE NOD) MODULE SPEC VOLTS CDC) 35.10 INV. QTY,MAX/BRANCH COT. INV.QTYBcI QTY 8 MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/'C -0.114 BRANCH OCT. OUTPUT, IMAXBC I (IAC•INV.QTYBC) 1 AMPS(AC) 7.68 MOD, MAX VOLTAGE(VMAXMoo) (Vac+(TD`COEF)) VOLTS(DO 41.06 INV. QUANTITY,TOTAL I INV.QTYT I QTY B MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS CDC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS I (IAC•INV.QTYT) I AMPS(AC) 7.68 MOD. SHORT OCT.CURRENT(ISC) MODULE SPEC AMPS CDC) 9.00 MOD. MAXIMUM CURRENT(IMAX) Osc- 1.25) AMPS CDC) I1,25 MIN.AMPACITY REQ'D,PER NEC ([MAX• 1.25) AMPS CDC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(Da) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 8 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 B ENPHASE I116-60-2-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR 5 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER.I X 2GA-2P, I X 5A-IP SOLAR B I CUTLER-HAMMER TBD PV BREAKER, I X 2DA-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 10 TBD TBD UTILITY METER,IPH, 120/24OV,20GA BLDR. ELEC. II TBD. TBD GROUNDING ELECTRODE,UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS H CONDITION OF USE(COU) I (AMPACITY - TEMP. DERATE •FILL DERATE)ys. REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM I AMPACITY AT TERMINALS.is. REG'D,(IMAX • 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC, AMPACITY WIO TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) M7.681 MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 PV COED DEVICE USED AMPS 20 e #10 CU NM-B CDU 40 0.91 1.0 36.40 INTERCONNECTION CALCS: TERM 35 35 o.96A x e(MoDs)- zfiBA OF CURNEM C #10 CU NM-B COU 40 0.91 1.0 36.40 zfieA x Lzs=TERM 35 35 TIE-IN WITN A iDAI2 2 SPACE PV BACKFEED BREAKER CONDUCTOR SCHEDULE KEY 1 CONDUCTORS CU/AL TYPE I LOCATION I TRADE A 1 1-#12 ENPHASE Q CABLE.I-#6G,FREE AIR I CU I UL3003,DG CABLE ARRAY SOLAR B 3-#10, I-#10 EGO I CU I NM-S CROMEX) I INTERIOR I SOLAR C 1 3410, 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 10 O 9 5 O a D 'N G � G 6J ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.120KW LOT#83 ORIGINAL BY:SHAUN MARUNA DATE:IJ.0S.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE:17.05.17 CORONA,CA 990 A,CA I 2 DRIVE,#302 92079 REV.# BY DATE DESCRIPTION namasti§ SOLAR DWG TITLE: PAGE St: SCALE: SITE LOCATION: INDIVIDUAL 457t ,GO 8Street PLOT PLAN 2 NTS 28668 FIELDGRASS ST BO303,Idw30004 ELECTRICAL MENIFEE,CA 03.447.000 STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(?)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION, 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES- GENERAL- 0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING, NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH.AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- I6)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. I7)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10', BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:SHAUN MARUNA OATEITO5.17 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE0.05:17 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamast6 emna DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4671r,G ay Street 2E66E FIELDGRASS ST Ba3 1de03. OWO04 PLOT PLAN 3 NTS NOTES MENIFEE,CA 03.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE IZ=Zl UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP' 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 7.68A I PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:SHAUN MA NA DATE17.05.17 980 MONTECITO DRIVE,#3O2 HERITAGE HEIGHTS : REVIEWED BY:JIM PARKS DATE)7.05.17 80 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamc[sr6 soIAe DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4511 Broadway Street PLOT PLAN 4 NTS FIELDGRASS ST Boulder, 0803D4 MENIFEE PLACARDS ENIF ,CA 30.944Z0.'AO