Loading...
PMT17-03448 City of Menifee Permit No.: PMT17-03448 29714 HAUN RD. 4ACCELA7 MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 10/06/2017 PERMIT Site Address: 28696 FIELDGRASS ST, MENIFEE, CA Parcel Number: 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582 HERITAGE HEIGHTS Work: 9 MODULES,9 INVERTERS,2.39KW LOT 81 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtv Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of erors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Pennit_Tempete.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE:09/27/2017 PERMIT/PLAN CHECK NUMBER T Tl TYPE: O COMMERCIAL ESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: X ADDITION O ALTERATION 0 DEMOLITION 0 ELECTRICAL 0 MECHANICAL O NEW O.PLUMBING O RE-ROOF NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit- Plan 2131 - 2.39kW/9PCS Master Solar Permit No.: PMT17-00129 PROJECTADDRESS 28696 Fieldgrass St. ZIP 92584 ASSESSOR'S PARCEL NUMBER TBD LOT 81 TRACT31582 OWNER NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes Of California,. Inc. OWNER BUILDER? 0 YES (,NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 8017.20 SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 09/27/2017 DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE PERMIT FEE SMIP GREEN PLAN CHECK FEE INVOICE TOTAL OWNER BUILDER VERIFIED O YES tP NO DRIVERS LICENSE# NOTARIZED LETTER O YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityafmenifee.us SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 10TY MRR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALIY IN THE SYSTEM SIZE 2.385 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 9 PCS.1 HYUNDAI I HIS-S265RG (265W) BUYER- INVERTER I 9PCS.1 ENPHASE I 106-60-2-US ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION - ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 9 NA NA NA BUYER: TILT I8' NA° NA° NA' AZIMUTH 1 I80° 1 NA' I NA' NA' DATE: —_ CITY OF MENIFEE BUILDING AND SAFETY DEPARTMENT PLAN APPROVAL REVIEWED BY DID 'U ' DATE. Approval of these plans shall not be construed to be a wrmit for,or an approval of,any violation of any provisions of the fed ral,state or city regulations and ordinances.This set of approved plans must be kept on the jobsite until completion. t �y a� Ne SOLADECK WIRE TRANSITION BOX ' (UNDER ARRAY) AC COMBINER BOX PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER MAIN SERVICE PANEL (VERIFIED BY BUILDER) w ad NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2131 ELEVATION A-LEFT Z ORIENTATION 2 LOT#81 ORIGINAL BY:SHAUN MARUNA DATE:I7,05.IJ HERITAGE HEIGHTS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:17.05.17 CORONA,CA 92679 REV.# BY DATE DESCRIPTION Z-2amastA souv DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4 Broadway Street Z8696 FIELOGRASS 5T B Br C080304 PLOT PLAN I I/16'=I'-0' MENIFEE,CA 303.3033.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE /CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION FONTANA,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 36 INV. MODEL INVERTER SPEC 106-60-2-US TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -1 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 330 TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(DC) 48 TEMP,DELTA LOW(TOELTA) TMIN-TTEST 'C -26 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD, MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD, PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.96 MOD. POWER STC(P) MODULE SPEC WATTS(DD) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER RTC MODULE SPEC WATTS(00) 258 1 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD, OPERATING VOLTAGE CVMP) MODULE SPEC VOLTS CDC) 31.30 INV.GROUNDING INVERTER SPEC IISOLATED MOD. OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS CDC) 38JO INV. QTY,MAX 7 BRANCH CCT. INV.QTYBC QTY 1 9 MOD.COEFP. VOLT/TEMP(COST) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT, IMAX8C I(IAC'INV.GTYAC) I AMPS(AC) 1 8.64 MOD. MAX VOLTAGE(VMAXMDD) (VOC+(TD'COEF)) VOLTS CDC) 41.06 INV.QUANTITY,TOTAL I NV.QTYT I QTY 1 9 MOD, OPERATING CURRENT(IMP) MODULE SPEC AMPS CDC) 6.50 TOTAL SYSTEM OUTPUT. IMAXTS (IAC'INV.QTYT) I AMPS(AC) 1 8.64 MOD. SHORT CCT. CURRENT 0sc) MODULE SPEC AMPS CDC) 9.00 MOD. MAXIMUM CURRENT(IMAX) (Isc- 1.25) AMPS CDC) 11.25 MIN, AMPACITY REG D,PER NEC (IMAX'1.25) AMPS CDC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS CDC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 9 ENPHASE I126-60-2-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R, 240V,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-8 AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER. I X 20A-2P,1 X 5A-IP SOLAR 8 I CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC. 10 TBD TBD UTILITY METER,IPH, 120/240V,200A BLDR.ELEC. II TBD TBD GROUNDING ELECTRODE,LIFER BLOB. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU) I (AMPACITY - TEMP, DERATE -FILL DERATE)VS.REWO(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. M. REQ'O,(IMAX- 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W70 TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DEBATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.64 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.80 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 8,64 INTERCONNECTION CALLS: TERM 35 35 10-80 20 0.96A X 9(1O05)= 8.64A OF CURRENT C #10 CU NM-B COU 40 0.91 1.0 36.40 6.64 8.64A X I25= I0 .80A TERM 35 35 10.80 20 TIE-IN WITH A 20Al2P 2 SPACE PV BACKFEED BREAKER CONDUCTOR SCHEDULE KEY CONDUCTORS I CU/AL I TYPE LOCATION TRADE q 1-#12 ENPHASE Q CABLE, 1-#6G,FREE AIR CU UL3003,DIG CABLE ARRAY SOLAR B 1 3-#10,1-410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 1 3410, 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR 10 O 9 5 O4 SA/IP O O O O O OArzP 5 z6azP r `�N G G G A B C C = II I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385KW LOT#81 LENNAR: ORIGINAL BY:SHAUN MARUNA DATE:17.05.17 HERITAGE HEIGHTS 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE:17.05.17 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbAR Xoue DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Ber,GO 8 Street INDIVIDUAL PLOT PLAN 2 NITS28696 FIELDGRASS ST Boulder, 80304 ELECTRICAL MENIFEE,CA 303.447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(})SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES 12')BEYOND THE EDGE OF THE PV ARRAY/SUB ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3". 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT U')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90"C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703, IEC61646. IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMANLIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:SHAUN MARUNA JDATE17.05.17 HERITAGE HEIGHTS LENNAR REVIEWED BY.JIM PARKS DATE] .05.17 980.MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Vnamasb6 lOIA! DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 0.571 der,CO 8Street PLOT PLAN 3 NTS 28696 EIELDGRASS 5T B9303A47O80804 NOTES MENIFEE.CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLADECK WIRE TRANSITION BO% (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8.64A I PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:SHAUN MARUNA DATE:17.05.17 LENNAR: HERITAGE HEIGHTS REVIEWED BY:JIM PARKS IDATE7705.17 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# I BY DATE I DESCRIPTION V- namasth sous DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Sheet PLOT PLAN 4 NTS MENIF E,CA RASE ST BO303. CO30809 PLACARDS MENIFEE,CA 303.447.0000