PMT17-03446 City of Menifee Permit No.: PMT17-03"6
29714 HAUN RD.
4/K:CELh-? MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 1 010 612 01 7
PERMIT
Site Address: 28724 FIELDGRASS ST, MENIFEE, CA Parcel Number:
92584 Construction Cost: $8,017.20
Existing Use: Proposed Use:
Description of SOLAR TR 31682 HERITAGE HEIGHTS
Work: 8 MODULES, 8 INVERTERS,2.12KW
LOT 79
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number: 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALSO VIEJO, CA 92656
Fee Description r3yt Amount ISI
Solar, Residential or Small Commercial 1 252,00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
SAFETYBUILDING & PERMIT/PLAN CHECK APPLICATION
k
Menifee
DATE:09/27/2017 PERMIT/PLAN CHECK NUMBER l l�.l CAW
TYPE: C.COMMERCIAL RESIDENTIAL 0 MULTI-FAMILY MOBILE HOME C.) POOL/SPA O SIGN
SUBTYPE: PO(DDITION 0 ALTERATION Q DEMOLITION 0 ELECTRICAL G MECHANICAL
O NEW O PLUMBING 0 RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit- Plan 1782 - 2.12kW/BPCS
Master Solar Permit No.: PMT17-00129
PROJECTADDRESS 28724 Fieldgrass St. ZIP 92584
ASSESSOR'S PARCEL NUMBER TBD LOT 79 TRACT31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL Jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ()YES ONO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 8017.20 SQ L SQ FT
APPLICANT'S SIGNATURE --DATE-09/_H 17
CITY STAFF U
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
ACCEPTED BY:
BUILDING PLANNING ENGINEERING FIRE
PERMIT FEE r)q L[. r. SMIP GREEN
PLAN CHECK FEE INVOICETOTAL
OWNER BUILDER VERIFIED %YES O NO DRIVERS LICENSE# NOTARIZED LETTER Q YES •-1 NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED.
ITEM OL MRS. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SY STEM SIZE 2.120 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 8 PCS.I HYUNDAI I HIS-S265RG(265W) BUYER
INVERTER I 3PCSj ENPHASE I IO6-60-2-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: — - - - - -
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD CITY 8 NA NA NA BUYER:
TILT 23' NA' NA' NA'
AZIMUTH 168' 1 NA' NA' NA' DATE.
i:,L) SAFETYDEPARTMENT 3' S'-5"
;N APPROVAL
REVIEWEDBY 10-LQ — _
11'J i.
rz
Approval of 16be plane shall not be construed to he a perm) foe
approval of,my violation of any provisions of the federal,s
sN
s:gulationa and ordinances.This set of approved plans mull
':"site until completion. .�
SOLADECK WIRE
TRANSITION BOX "—'—
(UNDER ARRAYI
AC COMBINER BOX '
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER e
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
MEMO
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 1782 ELEVATION C-LEFT �®
ORIENTATION 2 LOT#79
ORIGINAL BY:SHAUN MARUNA DATE:
17.05.17
HERITAGE HEIGHTS LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE:17.05.17
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
;Pmamast;6
anrea
DWG TITLE: PAGE*: I SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 28724 FIELDGRASS ST Boulder,CO W304
PLOT PLAN I/16"=I'-0" MENIFEE,CA 303.447.030D
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION FONTANA,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 36 INV. MODEL INVERTER SPEC 106-60-2-US
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -I INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 330
TEMP,.MODULE TEST(TTEST) MODULE SPEC 'C 25 INV. INPUT V,(Vx MAX) INVERTER SPEC VOLTS(Do) 48
TEMP,DELTA LOW(TDELTA) THIN-TTEST 'C -26 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.96
MOD. POWER STC(P) MODULE SPEC WATTS(130 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER RTC MODULE SPEC WATTS(DO 238 COMPLIANCE INVERTER SPEC UL1741/1EEE1547
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DG) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN OCT. VOLTAGE(Vac) MODULE SPEC VOLTS(DO 38.10 INV. CITY,MAX/BRANCH CCT. INV.OTYSC CITY 8
MOD. COEFF. VOLT/TEMP(COOT) MODULE SPEC V/'C -0.114 BRANCH CC 1.OUTPUT. IMAXBC (IpCINV.OTYSU AMPS(At) 7.68
MOD. MAX VOLTAGE(VMAXMOD) (VOC+(TD•COEF)) VOLTS(Dc) 41.06 INV. QUANTITY,I I INV.GTYT QTY 8
MOD, OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 8.50 TOTAL SYSTEM OUTPUT, IMAXTS I(IAC-INV.QTYT) AMPS(AC) 1 7.68
MOD, SHORT GOT. CURRENT 0sc) MODULE SPEC AMPS(DC) 9.00
MOD. MAXIMUM CURRENT(TMAX) (Isc• 1,25) AMPS(OC) 11,25
MIN.AMPACITY REQ D,PER NEC (IMAX' 1.25) AMPS(DC) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY CITY MANUFACTURER MODEL NOTES TRADE
I 8 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 8 ENPHASE I06-60-2-US PV INVERTER SOLAR
3 1 RSTC /SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR
6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR
7 1 ENPHASE TBD PV BREAKER, I X 20A-2P.I X 5A-IP SOLAR
8 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR
9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC.
10 1 TBD TBD UTILITY METER, IPN,120/240V,200A BLDR. ELEC.
II 1 TBD TBD GROUNDING ELECTRODL.UFER BLDR. ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COO): (AMPACITY • TEMP.DERATE -FILL BERATE)vs. REQ'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM). AMPACITY AT TERMINALS. M. REQ'D.(IMAX' 1,25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/D TEMP. FILL RESULT REODWL�IIED
BUS RATING AMPS 200
TYPE BERATES BERATE DEBATE (A) (A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 7.68ALLOWED PV PER NEC AMPS 40
TERM 25 25 9.60pV OCPD DEVICE USED AMPS 20
B #10 Cu NM-B cou 40 0.91 1.0 36.40 7,68INTERCONNECTION CALCS:
TERM 35 35 9.600.96A x 6(MODS)= 7.6BA OF CURRENT
#10 CU NM-B GOU 40 0.91 1.0 36.40 7.6876BA x L25= '0'TERM 35 35 9.60TIE-W WITH A 20A/2P 2 SPACE PV BACKFEEO BREAKER
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU AL TYPE I LOCATION I TRADE
A 1 1-#12 ENPHASE 0 CABLE, I-#6G,FREE AIR I CU UL3003.DG CABLE ARRAY SOLAR
B 1 3-#10, 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
C 1 3-#10, 1410 EGC I CU I NMI(ROMEX) I INTERIOR I SOLAR
10
ND
9
5 = O4
54/IP O
O O d0A/
a
20A/
— N
G G
A B C C = II
I I I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.12OKW
LOT#79
ORIGINAL BY:SHAUN MARUNA DATE:17.05.17
HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE:17.05.17
CORONNA,A,C CA 92870
980 I DRIVE,#302 REV.* BY DATE DESCRIPTION
A
namastAR
XotAe
DWG TITLE: PAGE#: SCALE: SITE LOCATION 4571 9roeawey Street
INDIVIDUAL 28724 FIELDGRASS ST Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH Q')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF
2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVEO PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS,
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. COMPOSITION SHINGLE
SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER
SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 9VC RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED.AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703. IEC6I646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS.SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT}"
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMANLIKE MANNER.
20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:SHAUN MARUNA DATE17.05.17
HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATEI7.05.17
980 MONTECITO DRIVE.#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
t1maI
SOLAN
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4571 Broadway Street
INDIVIDUAL
PLOT PLAN 3 KITS28724 FIELOGRASS ST Boulder,303.03.44].7. 80304
NOTES MENIFEE,CA 0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER e
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 7.68A
I PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:SHAUN MARUNA I DATE:17.05.17
HERITAGE HEIGHTS LENNAR:980 REVIEWED BY:JIM PARKS DATE:17.05.17
CORONA,CA NA CA I2 DRIVE,#302
CO 9287q REV.# BY DATE I DESCRIPTION
V IOtA2
wine
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway Street
INDIVIDUAL 28724 FIELDGRASS ST Boulder,DO 80304
PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300
PLACARDS