PMT17-03444 City of Menifee Permit No.: PMT17-03444
29714 HAUN RD.
<ACCELA^' MENIFEE, CA 92586 Type: Residential Electrical
MENIFEE Date Issued:
10/O6/2017
PERMIT
Site Address: 28713 FIELDGRASS ST, MENIFEE, CA Parcel Number:
92584 Construction Cost: $8,017.20
Existing Use: Proposed Use:
Description of SOLAR TR 31582 HERITAGE HEIGHTS
Work: 9 MODULES, 9 INVERTERS,2.36 KW
LOT 77
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number: 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description Olt Amount($1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Men"rfee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pernit_Template.rpt Page 1 of 1
APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK
"'Menifee
DATE:09/27/2017 PERMIT/PLAN CHECK NUMBER VFAI n J�
TYPE: O COMMERCIAL ESIDENTIAL C MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN
SUBTYPE: ADDITION C ALTERATION C DEMOLITION O ELECTRICAL O MECHANICAL
O NEW O PLUMBING O RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit- Plan 2131 - 2.36kW/ 9PCS
Master Solar Permit No.: PMT17-00129
PROJECTADDRESS 28713 Fieldgrass St. ZIP 92584
ASSESSOR'S PARCEL NUMBER TBD LOT 77 TRACT31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California., Inc. OWNER BUILDER? O YES C.,NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 8017.20 SQ FT L SQ FT
APPLICANT'S SIGNATURE DATE 09/27/2017
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE ACCEPTED BY:
PERMIT FEE q . L1 SMIP GREEN
PLAN CHECK FEE INVOICE TOTAL
OWNER BUILDER VERIFIED (:e YES NO DRIVERS LICENSE# NOTARIZED LETTER YES - NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofrnenifee.us
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY 1 HER. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 12.385 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 9 PCS. HYUNDAI I HIS-S265RG (265W) BUYER:--------
INVERTER 1 9 PCS.1 ENPHASE I 106-60-2-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 9 NA NA NA BUYER:
TILT 23' NA' NA' NA'
AZIMUTH 1 163- NA' NA" NA' DATE:
CITY OF MENIFEE
III IILDING AND SAFETY DEPARTMENT
PLAN APPROVAL
REVIEWED BY
DATE
Approval of these plans shall not be continued to be a permit for,or an
approval of,any violation of any provisions of the federal,state or city
regu a Ions and or din nces.This act of approved plans must be kept on the
jobsite until completi n.
rz
ai
�y a
ag
ma
N
1
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY) manow
AC COMBINER BOX
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER e
{ MAIN SERVICE PANEL
„^ (VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2131 ELEVATION C.-RIGHT ®�
ORIENTATION 4 LOT#77
LENNAR: ORIGINAL BY:SHAUN MARUNA DATE:17.05.I7
HERITAGE HEIGHTS
980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:17.05.17
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
;2amastA
mtae
OWE TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 28713 FIELDGRASS ST Bu01Lar,CO 80304
PLOT PLAN 1 1/16'= 1'-0' MENIFEE,.CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE /CALC UNIT DETAIL
LOCATION FONTANA,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% 'C 36 INV. MODEL INVERTER SPEC IQ6-60-2-US
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -1 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 330
TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS OF) 46
TEMP,DELTA LOW(TDLLTA) TMIN-TTEST 'C -26 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(Ac) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.96
MOD, POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER PTC MODULE SPEC WATTS(DC) 238 1 COMPLIANCE INVERTER SPEC UL174I/IEEEI547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31,30 INV. GROUNDING INVERTERc SPEC ISOLATED
MOD. OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 38.10 INV.QTY,MAX/BRANCH CCT. INV Q Ye QTY 9
MOD, COEFF.VOLT/TEMP(COEF) MODULE SPEC V/'C -0.114 BRANCH CCT. OUTPUT, IHAXBC (IAC-INV.QTYBC) AMPS(AC) 8.64
MOD. MAX VOLTAGE(VMAXMOD) (VOC t(TD-COEF)) VOLTS(DO 41.06 INV. QUANTITY,TOTAL I INV.OTYT QTY 9
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT, IMAXTB I(IAC-INV..QTYT) AMPS(AC) 1 8.64
MOD. SHORT CCT. CURRENT OSC) MODULE SPEC AMPS(DU 9.00
MOD. MAXIMUM CURRENT(IMAX) (ISO' 1.25) AMPS(or) 11.25
MIN.AMPACITY REQ'D, PER NEC (IMAX` 1.25) AMPS(DU 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE
1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 9 ENPHASE IQ6-60-27 PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,1201) SOLAR
6 1 ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR
7 1 ENPHASE TBD PV BREAKER, IX 20A-2P, IX 5A-IP SOLAR
8 1 CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P,RATING MAY VARY SOLAR
9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC.
t0 I T D UTLTY METER,]PH,120/24OV,200A BL L
II D TTD GROUNDINGELECTRODE,UFER DRREE .
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
D CONDITION OF USE(COU): (AMPACITY- TEMP. DEBATE • FILL DERATE)vs. REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS. REQ'D,(I.AX • 125) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D DIED BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 1 22.80 8.64 ALLOWED PV PER NEC AMPS 40
TERM 25 25 10.80 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B COU 40 0.91 1.0 36.40 8.64 INTERCONNECTION CALCS:
TERM 35 35 10.80 20 0.96A X 9(MODS)= 8.60 OF CURRENT
C #10 CU NM-B COU 40 0.91 1.0 36.40 8.64 8.64A X 1 25= 10.BOA
TERM 35 35 10.80 20 TIE-IN WITH A 20A/2P 2 SPACE PV BACXFEED BREAKER
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE
A I-#12 ENPHASE Q CABLE,1-#6G,FREE AIR CU UL3003,DG CABLE ARRAY SOLAR
B 1 3-#10, 1-#10 EGG I CU I NM-B(ROMEX) I INTERIOR SOLAR
C 3-#10. 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
10
O
O I 9
I
5 O4
!2k
O O 20O
r N
G G G
A B C C = II
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.385KW
LOT#77
LENNAR: ORIGINAL BY:SHAUN MARUNA DATE:17.05.17
HERITAGE HEIGHTS 980 MONTECITO DRIVE,#302 REVIEWED BYtJIM PARKS DATE:17.05.17
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Vn(3mast;6
vnuv
DWG TITLE: M2NTS
SCALE: SITE LOCATION:
INDIVIDUAL 4Bo &o,CO8Street
PLOT PLAN 28713 FIELDGRA55 ST Boulder,C080304
ELECTRICAL MENIFEE,CA 303.447.0300
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 481,O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3, PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2'9 BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVEO PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.COMPOSITION SHINGLE
SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER
SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
I2)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED IZOV BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT).FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT�.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT;WIRING/RACEWAYS SMALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:SHAUN MARUNA DATE17.05.17
HERITAGE HEIGHTS 9LENNAR80MO: REVIEWED BY:JIM PARKS DATEITOS.n
CORONA,
NA,CA I92 DRIVE,#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION tit
mast6
.o..
DWG TITLE PAGE AN SCALE: SITE LOCATION:
INDIVIDUAL 4571 Ber,00 3 304
PLOT PLAN 3 NTS MENI FELDGRASS ST Bo303. 7. B0804
NOTES MENIFEE.CA 803.44T0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM, DISCONNECTS
ARE LOCATED AS SHOWN.
m1-ADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER A
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 8.64A
I PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:SHAUN MARUNA DATE17.05.I7
HERITAGE HEIGHTS LENNAR: REVIEWEDB`:JIM PARKS DAM7,05.17
CORONA,
NA,CA I92 DRIVE,#J02
CORONA,CA 92B79 REV.# BY DATE DESCRIPTION
Vnamasrd
sore•
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4571 Broadway Street
INDIVIDUAL IMENI EE.FIELDGRASS ST Boulder,C080304
PLOT PLAN 4 NTS MENIFEE.CA
303.497.0300
PLACARDS