PMT17-03443 City of Menifee Permit No.: PMT17-03443
29714 HAUN RD. T Residential Electrical
SNCCELA� MENIFEE, CA 92586 Type:
MENIFEE Date Issued: 10/06/2017
PERMIT
Site Address: 28699 FIELDGRASS ST, MENIFEE, CA Parcel Number:
92584 Construction Cost: $8,017.20
Existing Use: Proposed Use:
Description of SOLAR TR 31582 HERITAGE HEIGHTS
Work: 12 MODULES, 12INVERTERS,3.180 KW
LOT 76
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description Qtv Amount l5l
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
4
Menifee
DATE:09/27/2017 ���� PERMIT/PLAN CHECK NUMBER
TYPE: O COMMERCI L �SRESIDENTIAL 0 MULTI-FAMILY O MOBILE HOME 0 POOL/SPA Ci SIGN
SUBTYPE: < ADDITION O ALTERATION O DEMOLITION C ELECTRICAL a MECHANICAL
O NEW a PLUMBING 0 RE-ROOF NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit - Plan 2686 - 3.18kW/ 12PCS
Master Solar Permit No.: PMT17-00129
PROJECTADDRESS 28699 Fieldgrass St.. ZIP 92584
ASSESSOR'S PARCEL NUMBER TBD LOT 76 TRACT31582
OWNER NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE 951-817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? 0 YES ONO
BUSINESS NAME Lerner Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302,Corona, CA 92879
PHONE 951-817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 8017.20 SQ FT L SQ FT
APPLICANT'S SIGNATURE DATE 09/27/2017
DEPARTMENT DISTRIBUTION ACCEPTED BY: CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE
PERMIT FEE q. (.D SMIP GREEN
PLAN CHECK FEE INVOICE TOTAL
OWNER BUILDER VERIFIED O YES ::; NO DRIVERS LICENSE# NOTARIZED LETTER YES 0NO
City of Menefee
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92_BI0P6*j8@0Y Dept.
www.cityofinenifee.us 5EP 2 9 2017
Received
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 3.180aW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 12 PCS. HYUNDAI I MiS-S265RG (265W) BUYER:
INVERTER 1 12 PCS.I ENPHASE I ID6-60-2-US
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE-
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 12 NA NA NA BUYER:
TILT 23" I NA- NA' NA'
AZIMUTH 176- NA° NA- NA' DATE:
<'11 Y OF MENIFEE
BUILDING AND SAFETY DEPARTMENT
PLAN APPROVAL
�_0RF.VTFWFD BY
VC DATE
Approval of these plan shall not be construed to he a permit for,or an
approval of,any violati n of any provisions of the federal,state or city
regulations and ordina es.This set of approved plans must be kept on the
jobsite until completio
r�
ai
�5
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
_ AC COMBINER BOX
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2686 ELEVATION C-RIGHT ®Z
ORIENTATION 4 LOT#76
LENNAR: ORIGINAL BY:SHAUN MARUNA DATE'I7.OS.17
HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE:17.05.17
CONA,CA I92 DRIVE,#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namaste
rer..
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
9571 BecBoulder.
GO
8 Street
PINDIVIDUAL 25699 EIELDGRASS ST Boulder, 70300
PLOT PLAN I/Ifi'=I'-0' MENIFEE.CA 303.497.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE , CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC IG6-60-2-US
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 330
TEMP,MODULE TEST(TTEST) MODULE SPEC 'C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(oc) 48
TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 INV.OUTPUT V.(VAc MOM) INVERTER SPEC VOLTS(Ac) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.96
MOD. POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER PTC MODULE SPEC WATTS(or) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DU 31,30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT. VOLTAGE WOO MODULE SPEC VOLTS(DO 38-10 INV.GTY,MAX/BRANCH CCT. INV.OTYBc CITY 12
MOD, COEFF. VOLT/TEMP(COEF) MODULE SPEC V/'C -0.114 BRANCH CCT. OUTPUT, IMAXBC (IAC'INV.QTYAC) I AMPS(AC) 1 11.52
MOD. MAX VOLTAGE(VMAXMOD) (VOC+(TD-COEF)) VOLTS(DC) 41.18 INV. QUANTITY,TOTAL INV.GTYT STY 1 12
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(Dc) 8.50 TOTAL SYSTEM OUTPUT, IMAXTE (IAC-INV.QTYT) AMPS(AC) 1 11.52
MOD. SHORT CCT.CURRENT OSC) MODULE SPEC AMPS(Dc) 9.00
MOD. MAXIMUM CURRENT(MAX) (ISC' 1.25) AMPS(DC) 11.25
MIN.AMPACITY REQ'D,PER NEC (IMAX• 1.25) AMPS 00 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(oC) 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE
1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 12 ENPHASE IQ6-60-2-US PV INVERTER SOLAR
3 1 RSTC/.SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR
5 1 ENPHASE IQ ENVOY ENV-IOAMI-240 PV DATA MONITOR, 120V SOLAR
6 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR
7 1 ENPHASE TBD PV BREAKER, IX 2OA-2P, IX 54-2P SOLAR
8 1 CUTLER-HAMMER TBD PV BREAKER,IX 20A-2P,RATING MAY VARY SOLAR
9 1 TBD TBD SERVICE PANEL,200A BUS BLDR.ELEC,
10 TBD TBD UTILITY METER,IPH, 120/24OV,200A BLDR ELEC.
II TBD TBD GROUNDING ELECTRODE, LIFER BLDR. ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU) (AMPACITY • TEMP. DERATE ' FILL DERATE)VS. REO'D 0m.X) ITEM UNIT PANEL
2)TERMINALS(TERM). AMPACITY AT TERMINALS. vs. REO'D.OMAX - 1.251 PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/0 TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DEBATES DEBATE DEBATE (A) (A) USED(Al MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 11.52 ALLOWED PV PER NEC AMPS 40
TERM 25 25 14.40 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B CCU 40 0.91 1.0 36.40 11.52 INTERCONNECTION CALCS:
TERM 35 35 14.40 20 0.96A x I2(1ODS)= 11.52A OF CURRENT
C #10 CU NM-B COD 40 0.91 1.0 36.40 11.52 IL52A x L25= 11.11A
TERM 35 35 14.40 20 TIE-IN WITH A 20A/2P 2 SPACE PV BAIXFEED BREAKER
CONDUCTOR SCHEDULE
KEY CONDUCTORS 1 CWAL TYPE LOCATION I TRADE
A 1-#I2 ENPHASE Q CABLE,I-#6G,FREE AIR CU UL3003,DO CABLE ARRAY SOLAR
B 3410,1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
C 3410, 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
NOTE:NEUTRAL NOT USED AND CAPPED 10
O
9
5 s 4O
5A/xP O
0 7
ZOA/2P
G
r _ N
A B C C
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 3.IBOKW
LOT#76
ORIGINAL BY:SHAUN MA NA I DATE17.05.17
HERITAGE HEIGHTS LENNAR:
980 I REVIEWED BY:JIM PARKS DATE:17.05.17
CORONNA,A.C CA A 92 DRIVE,#302 879 REV.# HV DATE I DESCRIPTION
�Pniamcist;6
cove
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroaMrey Street
INDIVIDUAL 28699 FIELDGRASS ST Bookler,CO 80304
PLOT PLAN 2 NTS MENIFEE,CA
308.447,0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
O ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION SOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 5'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3,PUB 140113-ICC.JANUARY ROIL.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(})SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL`TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 0)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SMALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. COMPOSITION SHINGLE
SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER
SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS.WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR.WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250,122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED I20V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY-SHAUN MARUNA DATE37.05.17
HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE17.05.17
980 MONTECITO DRIVE,#302
CORONA.CA 92679 REV.# BY DATE DESCRIPTION
namaste
iow
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 B=BWay Street
INDIVIDUAL 28699 FIELDGRASS ST Boulder,CO 80304
PLOT PLAN 3 NTS MENIFEE,CA
NOTES 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
KILITY METER A
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 11.52A
I PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:SHAUN MARUNA I DATE17.05.17
HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATE17.05.17
CO NA,CA I92 DRIVE,#302 REV.# BY DATE DESCRIPTION •,
CORONA,CA 92879
n SOLAR
:oleo
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway,GO8Street
PLOT PLAN 4 NTS MENIF FIELDGRASS ST Boulder, 7030004
PLACARDS MENIFEE,CA 303.447.0300