PMT17-03060 City of Menifee Permit No.: PMT17-03060
29714 HAUN RD. Type: Residential Electrical
'fkCCEL/> MENIFEE,CA 92586
MENIFEE Date Issued:
08/29/2017
PERMIT
Site Address: 30556 LONE PINE DR, MENIFEE, CA Parcel Number: 358-682-004
92584 Construction Cost: $16,000.00
Existing Use: Proposed Use:
Description of SOLAR TR 32025 THE RIDGE
Work: 12 MODULES W/MICRO-INVERTERS,4.02 KW LOT 156
Owner Contractor
RICHMOND AMERICAN HOMES SUNPOWER CORPORATION SYSTEMS
5171 CALIFORNIA AVENUE SUITE 120 77 RIO ROBLES
IRVINE, CA 92617 SAN JOSE, CA 95134
Applicant Phone:9417203850
NEIL DELUCENAY License Number. 890895
77 RIO ROBLES
SAN JOSE, CA 95134
Phone:7143513396
Fee Description O_yt Amount($1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 3.00
General Plan Maintenance Fee-Electrical 1 12.60
$295.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractor's State License Law for
Professions Code and my license is in full force and effect the following reason:
License Class (7 c Licens 8_90By my signature below I acknowledge that,except for my personal residence
Expires aq4 Signature in which I must have resided for at least one year prior to completion of
Improvements covered by this permit.I cannot legally sell a structure that I
WORKER'S COMPENSATION DECLARAT have built as an owner-builder if It has not been constructed in its entirety by
D I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a ropy of the applicable law,Section
have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when
compensation,Issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which this permit Is Issued. www.leginfo.ca.cov/calaw.html.
Policy# Date
inI have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT
section 3700 of the Labor Code,for the performance of the work for which D By my signature below I certify to each of the following:I am the property
this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this
number are: application and the information I have provided is correct I agree to comply
2 with all applicable city and county ordinancas and state laws relating to
Carder building construction.I authorize representatives of this city or county to
Policy# wnM/AtS— Expireslit enter the above identified property for inspection purposes.
(This section need not to be completed is the permit is for one-hundred Date
dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT
❑I certify that in the performance of the work for which this permit is issued, Kzr1�
I shall not emolov any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# o✓J--��*��..9
workers compensation laws of California,and agree that�ff should become HAZARDOUS MATERIAL DECLARATION
subject to the workers compensation pro vislo ct�ion 3700 of the Labor
Code,I shall forthwith co with rovisions. j ) Will the applicant or future building occupant handle hazardous material or
Applicant Date 17 1�( mixture containing a hazardous material equal to orgreater that the
amounts specified on the Hazardous Materials Information Guide?
WARNING: RE TO SEC WORKER'S COMPENSATION COVERAGE IS D Yes D No
UNLA ,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)7 See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines
CONSTRUCTION LENDING AGENCY ❑Yes ❑No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit is issued outer boundary of a school?
(Section 3097 Civil Code) o Yes o No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of
Contractors License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25S
5 u 1-25534"tonceming
hazardous material reportin
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 �— .
Business and Professions Code).Any city or county that requires a permit to °Yes °No
construct,alter,improve,demolish or repair any structure,prior to its ate
PROP
issuance,also requires the applicant for the permit to file a signed statement
ERTY AUT ED AGENT
that he or she is licensed pursuant to the provisions of the Contractors State EPA RE OVATION.REPAIR AND PAINTING IRRP)
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors
Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paintin a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RAP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500). managers who do the paint-disturbing work themselves or through their
D I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.gov/lead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code,The Contractors State License Law does not apply to an owner of a D An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not Intended or offered for Certified Finn Name:
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. D No EPA Lead-Safe Certified Firm is required for this project because:
D I,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions .
Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RAP rule please fill out the RRP
Acknowledgement.
— I 1 --.A e " n
Ir & SAFETYAPPLICATION
`Menifee
DATE 08/21/2017 PERMIT/PLAN CHECK NUMBER PVT
TYPE: ❑COMMERCIAL ❑d RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA []SIGN
SUBTYPE: [-]ADDITION ❑ALTERATION ❑DEMOLITION [Z]ELECTRICAL ❑MECHANICAL
❑NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Roofmount Solar Installation 4.02kW
12 Modules w/Micro-Inverters
PROJECT ADDRESS 30556 LONE PINE DRIVE .� r
ASSESSOR'S PARCEL NUMBER J �Y�C) 2- 0D LOT 156 TRACT
PROPERTY OWNER'S NAME RICHMOND AMERICAN HOMES
ADDRESS 5171 CALIFORNIA AVE.SUITE 120, IRVINE,CA 92617
PHONE EMAIL
APPLICANT NAME Tyler Santangelo
ADDRESS 3979 E.Guest Road,Suite B,Ontario,CA 91761
PHONE (714)351-3396 EMAIL tyler.santangelo@sunpowercorp.com
CONTRACTOR'S NAME Neil DeLucenay OWNER BUILDER? ❑YES❑,/ NO
BUSINESS NAME SunPower Corporation, Systems
ADDRESS 1414 Harbour Way South,Suite 1901, Richmond,CA 94804
PHONE (951)681-5483 EMAIL tyler.santangelo@sunpowercorp.com
CONTRACTOR'S STATE LIC NUMBER 890895 LICENSE CLASSIFICATION B,C10,t46,A
VALUATION$ $ 16,000.00 SQ FT 210 L SQ FT
11 APPLICANT'S SIGNATURE DATE 08/21/2017
TCITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION Dye —^ CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN �' l' SMIP '
INVOICE rJ t/ PAID AMOUNT
AMOUNT L I "J • v CASH C%CHECK# G CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT 0 CASH 0 CHECK# O CREDIT CARD VISA/MC
OWNER BUILDERVERIFIED 0 YES ^ NO DL NUMBER NOTARIZED LETTER YES 0 NO
City D,*'Meni,*ee 6uiiding&Safeiy Depart.r,2. 29714.Houn Rd. Menifee, C4 92586 951-672-6777
www.cityofinenifee.us Inspection .Request Line 951-246-5213
NOTES:ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR
INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY.
ARE 3'WIDE FIRE ACCESS PATH
DIMENSIONS OF THE INSET ARE LARGER THAN THE ARRAY AND SHALL BE
CONFIRMED BY THE BUILDER BEFORE THE INSTALLATION.
Q- —5 15'-6 ROOF ACCESS POINT
r ________________
iF1
CONCRETE [] O y LO
TILE ROOF I I
i
O
N look
dMIN
IL
� U
i
o
p �
I
o b
4:12 JUNCTION BOX
I
i
I
o ;
I
(1 (I UTILITY AC DISCONNECT SWITCH
----------- (OUTSIDE GARAGE WITHIN SIGHT
FROM THE MAIN SERVICE PANEL)
IING ANDSAFETY DEP SERVICE METERIPOINT NG
.�.,1�� � � UTILITY METERING
'JI 'lA APPROVAL0 +��11GG
"i(Fa11,IT E— y -3, TO ELECTRIC
UTILITY GRID
DATE
.4ppmval of'thm pin,'h.11 not be conatmed M be ALES
Bpptoval of,any viol.lioh of.cty pmvicionc o�l — 'BCK-D-AC
re`nlatiON and"n.nea.yhia aet of epprovW p' [A�he E)
Job**Iwd eoatpl.ti.tt.
PLAN S24P (PAIGE) (SCHEME 4)
ELEVATION C (4.02 W)
S24P(PAIGE) C M
S U N POWE R THE RIDGE AT AUDIE MURPHY RANCH FLAT TI
OF LE INDIVIDUAL
I PLOT PLAN
CORPORATION, SYSTEMS RIGHT�r np ARRAY LAYOUT
B sQ
1414 HARBOUR WAY SOUTH 173^ou 402 kW CMµxm Rensiox
RICHMOND, CA 94804 on srteinunox SlOm HOMEnPE nFM AENRIQUEZ 0
510 5 4 0-0 5 5 0 RICHMOND AMERICAN HOMES 30556 LONE PINE DRIVE 1-STORY 412
S 156
AMIT .m. �T
5171 CALIFORNIA AVE.SUITE 120 MENIFEE,CALIFORNIA 92584 215 SQ.FF. OB-20-201] snsv
215
IRVINE,CA 92617 P3MA5E
1/16"=V-O"