PMT17-03039 City of Menifee Permit No.: PMT17-03039
29714 HAUN RD.
<;-C ELA)' MENIFEE, CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 08/2812017
PERMIT
Site Address: 24860 COLDWATER CANYON TR, Parcel Number: 358-680-002
MENIFEE,CA 92584 Construction Cost: $6,778.88
Existing Use: Proposed Use:
Description of SOLAR TR 32025 DAKOTA 8 PANELS, 8 MICROINVERTERS,2.560 kW LOT 69
Work:
Owner Contractor
WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC
11870 PIERCE STREET,#250 760 NORTHWEST 107 AVENUE
RIVERSIDE, CA 92505 MIAMI, FL 33172
Applicant Phone:3054854110
KRISTEN MURRAY License Number: 1001133
SUNSTREET ENERGY GROUP LLC
760 NORTHWEST 107 AVENUE
MIAMI, CA 33172
Fee Description Oft Amount(El
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
PERMIT/PLAN& SAFETY • .
Menif(
DATE 08/14/2017 PERMIT/PLAN CHECK NUMBER -
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: [—]ADDITION []ALTERATION []DEMOLITION ❑J ELECTRICAL ❑w"raftnifee
[-]NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES Building Dept
DESCRIPTION OF WORK 2.56kW ROOF MOUNTED PV SYSTEM
PROJECT ADDRESS 24860 COLDATER CANYON,MENI FEE,CA 92584 Received
ASSESSOR'S PARCEL NUMBER 358-680-002 LOT 69 TRACT 32025
PROPERTY OWNER'S NAME WOODSIDE HOMES
ADDRESS 11870 PIERCE STREET SUITE 250
PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM
APPLICANT NAME KRISTEN MURRAY
ADDRESS 6531 IRVINE CENTER DR SUITE 200
PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM
CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YESQNO
BUSINESS NAME SUNSTREET ENERGY GROUP LLC
ADDRESS 6531 IRVINE CENTER DR SUITE 200
PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM
CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B
VALUATION $ $6,778.88 SO FT 200 L SO FT
APPLICANT'S SIGNATURE DATE 08/14/2017
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP
INVOICE PAID AMOUNT `
AMOUNT l�O ?j•1p >CASH 0CHECK# D CREDIT CARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT C:CASH 0CHECK# 0 CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED YES C) NO DLNUMBER NOTARIZED LETTER 0 YES NO
City of Vienifee u"ui!ding&Safety Department 2E714 Houn Rd. Menijee, CA 92
www.cityoj'men;fee.us Inspeczion Request Line 952-246-621.
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM I OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE l2.56OKW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 8 PCS.1 LG LG320NIK-A5(320W) BUYER:
INVERTER BPCS.1 ENPHASE I 1O6PLUS-72-ACM-US
ROOF TYPE CONC. TILE DATE: -
SUB-ARRAY INFORMATION
ARRAY#I 1 ARRAY#2 ARRAY#3 ARRAY#4
MOD OTY 8 NA NA NA BUYER:
TILT IF NA- I NA-
AZIMUTH 1 1767 1 NA' I NA* NA° DATE:
City cf h4enifea
6uiiding Dept
AUG 2 5 2017
Received
LITY OF MI
BUILD114G
PLAN A PPI
3' 26'-I0'ARRAY REVIE EC
SOLADECK WIRE
TRANSITION BOX n ,
(UNDER ARRAY) _°
'Approval Ifthr.
PV AC DISCONNECT 4
EXTERIOR-GARAGE ^ approval
UTILITY METER 8 regUiBtlo
MAIN SERVICE PANEL Jobsite R:.
(VERIFIED BY BUILDER)
ii 1S
AC COMBINER BOX. I
`aJ
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
PLAN 2 ELEVATION R OPT-L
ORIENTATION I LOT#69
WOODSIDE HOMES: ORIGINAL BY.BRI MORRIS DATE:17.07.11
11870 PIERCE STREET.DAKOTA AT AUDIE REVIEWED BY:JIM PARKS DATE:17.07.II
MURPHY RANCH RIVERSIDE[CA 92505 SUITE#100 h REV.# BY DATE DESCRIPTION
Qh namasGe
eoue
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4571 l r ,G e8 Street
INDIVIDUAL MENIF COLDWATER CANYON TRAIL Boulder,C0B0304
PLOT PLAN /I6" = I'-0" MENIFEE,CA 303.447.O300
SYSTEM LAYOUT
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY MANUFACTURER MODEL NOTES TRADE
I 8 LG LG320NIK-A5 WOW) PV MODULE SOLAR
2 8 ENPHASE IQ6PLUS-72-ACM-US PVINVERTER SOLAR
3 1 ORBIT 2DB75-5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 I CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
5 1 ENPHASE IQ ENVOY ENV-IOAMI-240 PV DATA MONITOR. 120V SOLAR
6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR
7 1 ENPHASE TBD PV BREAKER, I X 20A-2P. I X 5A-IP SOLAR
8 1 CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,RATING MAY VARY SOLAR
9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC.
10 1 TBD TRD UTILITY METER, IPH, 120/24OV,200A BLDR ELEC.
II 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR. ELEC.
AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL
LOCATION MENIFEE,CA PANEL MFR. I CUTLER-HAMMER
TEMP,AMBIENT HIGH (TMAX) ASHRAE 2% °C 37 BUS RATING AMPS. 200
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 1 200
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 60
TEMP,DELTA LOW(TOELTA) TMIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20
MOD. MANUFACTURER. AC MODULE SPEC LG INTERCONNECTION CALLS:
MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(32OW) I.I7A x B(MODS)= 9.36A OF CURRENT
MOD. POWER STC(P) AC.MODULE SPEC WATTS(DO 320 9.36A x 1.25, 1130A
PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 20A/2P 2 SPACE PV MCKFEED BREAKER
MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280
NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264
NOMINAL OUTPUT CURRENT(IA6) AC MODULE SPEC AMPS(AC) 1.17
NOMINAL FREQUENCY/RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5
OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I
COMPLIANCE AC MODULE SPEC UL1741 / IEEE1547
GROUNDING AC MODULE SPEC ISOLATED iFE
MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 �D CCU
AC MODULE QUANTITY, MAX PER BRANCH CIRCUIT MOD. OTY ec QTY 8 SJ f G
BRANCH CIRCUIT OUTPUT. IMAXBC 0AC'MOD.QTY BCJ AMPS(AC) 9.36
AC MODULE QUANTITY.TOTAL MOD. OTY T QTY 8 �\I11 L
TOTAL SYSTEM OUTPUT IMAXTS (IAC•MOD, QTY T) AMPS(AC) 9.36 V M
CONDUCTOR SIZING CALCULATIONS
D CONDITION OF USE (CDU) (AMPACITY.TEMP. DERATE° FILL DERATE)VS. REQD(]MAX)
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs.REO'D,(TMAX' 1.25) y
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD 1
TYPE DERATES DERATE DERATE (A) (A) USED
A =2CUTHWN-2 COU 30 0.76 1.0 22.80 9.36
TERM 25 25 11,70 20B NM-B COU 40 0.91 L0 3&40 9.36TERM 35 35 11.70 20 an5 SW
C NM-B COD 40 0.91 1.0 36.40 9.36 Rion 01 any p
TERM 35 35 11.70 20
CONDUCTOR SCHEDULE lances This!
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE :1016
A -#12 ENFHASI, 0 CABLE,146G, FREE AIR I CU TC-ER I ARRAY SOLAR
B 1 3-#10,I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR 0
C 1 3-#10,I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O
JIN
5 e O
sA/IP 0 Q
G I G G
A B C C
I 1 I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.560KW
LOT#69
ORIGINAL BY:BRI MORRIS DATE-17.07.
11670 PIERCE STREET,SUITE#100 11
DAKOTA AT AUDIE WOODS HOMES: REVIEWED BY:JIM PARKS DATE:17.07.11
MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION •�
Qla namasb€
'.tAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway Street
24860 COLDWATER CANYON TRAIL Boulder,CO80304
PLOT PLAN 2 NTS
MENIFEE,CA 303.447.0300
ELECTRICAL
INSTALLATION NOTES.
SOLAR CONTRACTOR-
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS.ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,
APRIL 2016 EDITION
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(e)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(Y)BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
9)PV PANEL HAS BEEN TESTED BASED ON UL 1703.
10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY.
IL)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS.
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. ^cD RTr
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHO I�
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING, NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAYBE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC6I646. IEC61730. '
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ ENPHASE MICRO-INVERTER SYSTEM.
ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING.SHALL NOT MAKE CONTACT WITHO�&wd a be
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. siOns Of Feder
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. �.y�
14)A PV AGGREGATION PANEL(SUB.PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. )f A
wm SIGNAGE-
15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND.LOCAL CODES.
16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT P.
18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY:BRI MORRIS DATE17.07.11
DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS DATE17:07.1I
11870 PIERCE STREET.SUITE#100
MURPHY RANCH RIVERSIDE,CA 92505 REV# BY DATE I DESCRIPTION
Gra namasb8
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
INDIVIDUAL 467i&u.GO B Street
PLOT PLAN 3 NTS MENIF COLDWATER CANYON TRAIL Boulder.GO
NOTES MENIFEE.CA 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
s Ke wl.
rRaxrrlav eox
(DtAEP 4PRAY)
PV 4C DISCONNER
Ex1ERIM-E4Q>4E
OTRITY METER B
MIN SERVICE PMi
(VERIFED 9Y&II LDEA)
uCC0"I ,Y RD PTE
mi for,or an
;ta a or city
st e kept onthe
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED
AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN
AC OPERATING CURRENT: 7.20A
I PC., NEC 690.54 1 PC., NEC 690.12
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY:BRI MORRIS DATE17.07.11
DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS DATE17.07.I1
11870 PIERCE STREET,SUITE#I00
MURPHY RANCH RIVERSIDE.CA 92505 REV.# BY DATE DESCRIPTION 09
namast8
WLId
DWG TITLE: PAGE 11 SCALE: SITE LOCATION: 4571 Broadway Sheet
INDIVIDUAL 24860 COLDWATER CANYON TRAIL Boulder,CO 803N
PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300
PLACARDS