Loading...
PMT17-03037 City of Menifee Permit No.: PMT17-03037 29714 HAUN RD. ,ACCEL/-> MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 08/28/2017 PERMIT Site Address: 24851 COLDWATER CANYON TR, Parcel Number: 358-681-015 MENIFEE, CA 92584 Construction Cost: $6.778.88 Existing Use: Proposed Use: Description of SOLAR TR 32025 DAKOTA 8 PANELS,8 MICROINVERTERS,2.560 kW LOT 97 Work: Owner contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET,#250 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description OQt Amount IEI Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pe"lt_Template.rpt Page 1 of 1 APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK Menifee DAlt 08/14/2017 PERMIT/PLAN CHECK NUMBER 7j 1 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION []DEMOLITION [Z]ELECTRICAL ❑MECHAtit LOf n�elllfE ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES ((:: .DESCRIPTION OF WORK 2.56kW ROOF MOUNTED PV SYSTEM 2017 PROJECT ADDRESS 24851 COLDWATER CANYON,MENI FEE, CA 92584 ASSESSOR'S PARCEL NUMBER 358-681-015 LOT 97 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑J NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $6,778.88 SO Fr 200 L SQ FT APPLICANT'S SIGNATURE ^ / , I- DATE 08/14/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP 1 INVOICE �1/lM�J/�� II nn PAID AMOUNT AMOUNT pC \�/• Wo I I O CASH E CHECK# O CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT OCASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO r„lii„of n4e;;i ee Building u Sofety Deportmenl29714 HGun Rd. ivlenifee, CA 92586 951-572-5777 www.cityofinenifee.us Inspmicn RequesE Line 95.7-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM I QTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.56OKW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE BPCS.1 LG I LG320NIK-A5(3207) BUYER: INVERTER 1 8 PCS.1 ENPHASE I IQ6PLUS-72-ACM-US ROOF TYPE I CONC. TILE DATE: SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 ARRAY#4 MOD QTY 8 NA NA NA BUYER: TILT IB° NAG I NAG NAG AZIMUTH 1 176° 1 NAG NAG NAG DATE: — City of Nlenitee Building Dept AUG 2 5 2017 Received r k SOLADECK WIRE TRANSITION BOX 26'-10"ARRAY 3' (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER IN MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX CITY OF A BUILD NG PLAN APP NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF REVIEVIED PLAN 2 ELEVATION A-R ORIENTATION 3 LOT#97 '*roaai of hm ORIGINAL BY:BRI MORRIS 1 DATE:17.07.11 Opplagwin a rfvb WOOOSIDE HOMES: DAKOTA AT AUDIE REVIEWED BY:JIM PARKS DATE:17.07.11 HIVE PIERCE STREET,SUITE#100 REV.# BY DATE DESCRIPTION � Je6ubtioM ad MURPHY RANCH RIVERSIDE,CA 92505 �I *bftmo cc 710et DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4Bo Broadway Street INDIVIDUAL04 24851 COLDWATER CANYON TRAIL Boulder,CO08004 PLOT PLAN 1 I716°=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES TRADE 1 B LG LG320NIK-A5(32OW) PV MODULE SOLAR 2 8 ENPHASE 106PLUS-72-ACM-US PV INVERTER SOLAR 3 I ORBIT 2DB75-5 PV ROOF JUNCTION BOX, NEMA 3R SOLAR 4 I CUTLER-HAMMER DG221URBr PV AC DISCONNECT.NEMA 3R,24GV,30A SOLAR 5 I ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER, I X 2OA-2P, I X 5A-IP SOLAR 8 I CUTLER-HAMMER TBD PV BREAKER,IX 20A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,ZOOA BUS BLDR. ELEC. 10 1 TBD TBD UTILITY METER.IPH, 120/24OV,20GA BLDR. ELEELEC. II 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR. C. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH (TMAX) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 MAIN DISCONNECT AMPS 200 TEMP. MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TELLTA) TMIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(320W) 717A x B(MODS)= 9.36A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS Oc) 320 9.36A x 625= IIJOA PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN wrTN A IM z SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/ZII-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY 1 RANGE AC MODULE SPEC HZ(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 / IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY Bc OTY 8 BRANCH CIRCUIT OUTPUT, IMAXBC 0AC'MOD.QTY Bc) AMPS(AC) 9.36 AC MODULE QUANTITY.TOTAL MOD. OTY T QTY 8 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD. OTY r) AMPS AC) 9.36 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE(COU): (AMPACITY' TEMP. DERATE ' FILL DERATE) s. REQ'D(IMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REO'D.(IMAX • 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DERATES DERATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 0.76 1 L0 1 22.80 9.36 TERM 25 25 11.70 20 B #10 CU NM-B. COU 40 0.91 1.0 36.40 9.36 TERM 35 35 11.70 20 C #IQ CU NM-B COU 40 0.91 1.0 30.40 9.36 TERM 35 35 11.70 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL 1 TYPE LOCATION 1 TRADE A -#12 ENPHASE 0 CABLE, -#6G, FREE AIR CU TC-ER. ARRAY SOLAR B 3-#10. 1-#10 EGG I CU I NM-B(ROMEX) I INTERIOR I SOLAR 0 C 1 3-#10, 1-#10 EGO CU NM-B(ROMEX) INTERIOR SOLAR O M 9 5 — 4 y WIP Q ,'IIFEE z O O 7 z�izN T��17 � ND SAFE DE SaAim r A B 7vAL C C _ I I ROOF EXTERIOR-GAFAGE ELECTRICAL DIAGRAM 2.56OKW LOT#97 ORIGINAL BY:BRI MORRIS DATE:17.07.11 S small not De ci ins" DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS DATE:17.07.11 11870 PIERCE STREET,SUITE#IGO REV.# BY DATE DESCRIPTION �__A of any prows ns of MURPHY RANCH RIVERSIDE,CA 92505 Qb W"i ol appm DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4571lder,D 8Street 24851 COLDWATER CANYON TRAIL Boulder,CO 0804 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 303.447.03W INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 40'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(?)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2")BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 6)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. IU BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS.OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC6I646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W7 ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110,26. ARTME ibea ermit ORIGINAL BY:BRI MORRIS DATE17.07.11 fedgr 1,SWt! DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS 1 DATE17.07.11 � % plans {ntbe 870 PIERCE STREET,SUITE#100 MURPHY RANCH RIVERSIDE,CA 92505 REV# BY DATE DESCRIPTION Lw Gd namasb6 sous DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4511 Broadway Street INDIVIDUAL PLOT PLAN 3 NTS 2485I COLDWATER CANYON TRAIL 303e COXX) NOTES MENIFEE.CA 03.44].0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SCIAREG WIPE (IMOER ARRAY) PV LC RIBRUNECT E%ERR-.N .E VIILITV METER B MIN SERVICE PANEL (VERIFIED BY BUILDER) 4C CDI6MER ERx SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR T PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 7.20A I PC., NEC 690.54 1 PC., NEC 690.12 DAT 0r an NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION city ORIGINAL BY:BRI MORRIS DATE:17.07.11 DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS I DATE:17.07.11 11870 PIERCE STREET,SUITE*100 MURPHY RANCH RIVERSIDE,CA 92505 REV# BY DATE I DESCRIPTION Qla namasrd fOLAI DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Broadway Street PLOT PLAN 4 NTS MENI GOLDWATER CANYON TRAIL Boulder, TO30304 PLACARDS MENIFEE,CA 303.447.0300