Loading...
PMT17-03036 City of Menifee Permit No.: PMT17-03036 29714 HAUN RD. 49CCELA? MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 08/28/2017 PERMIT Site Address: 24865 COLDWATER CANYON TR, Parcel Number: 358-681-014 MENIFEE, CA 92584 Construction Cost: $7,626.00 Existing Use: Proposed Use: Description of SOLAR TR 32025 DAKOTA 9 MODULES, 9 MICROINVERTERS, 2.88KW LOT 96 Work: Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET,#250 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 760 NORTHWEST 107 AVENUE MIAMI, CA 33172 Fee Description gtv Amount 1E1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 BUILDING : Menifee DATE 08/14/2017 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION ❑DEMOLITION [Z]ELECTRICAL [-]MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK 2.88kW ROOF MOUNTED PV SYSTEM q ifee Building ept PROJECT ADDRESS 24865 COLDWATER CANYON, MEN IFEE,CA 92584 17 ASSESSOR'S PARCEL NUMBER 358-681-014 LOT 96 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES e C e a d ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YESQNO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $7,626.24 SO FT 200 L SO FT APPLICANT'S SIGNATURE 'n' DATE 08/14/2017 �USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN — SMIP 1 INVOICE ��--��IIjj�y 11 ^^ PAID AMOUNT AMOUNT p/"l�• 1.4�� 0CASH OCHECKN C}CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK It 0CREDIT CARD ViSA/MC OWNER BUILDER VERIFIED ()YES O NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO e ej Meni <e ,clino R Se%e y Depar[meni 2971r1 Hcun Rd. Menifee, AV258c'951-672-6777 wwW.cityofinenifee.us inspection Request Line ?51-24E-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM QTY HER. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.88OKW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS.1 LG I LG320NIK-A5(320W) BUYER: INVERTER 1 9 PCS.1 ENPHASE I Q6PLUS-72-ACM-US ROOF TYPE I CONC. TILE DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 MOD QTY 9 NA NA NA BUYER: TILT IB' NA' NA' NA' AZIMUTH 1 76° M. NA* NA' DATE: fos 6Uiiding Dept AUG 2 5 2017 Received 30'-Z'ARRAY SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) CIT OF I AC COMBINER BOX BUI DIA PLAN Al REVI WI NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF �PPro ofth PLAN 4 ELEVATION B Proval if,any^' ORIENTATION 4 LOT#96 ')egUl2 and, ORIGINAL BY:BRI MORRIS 17.07.11 DATE: WOODSIER HOMES: �� REVIEWED BY:JIM PARKS DATE:17.07.11 DAKOTA AT AUDIE 95 um I cam IIB70 PIERCE STREET.SUITE#100 MURPHY RANCH RIVERSIDE.CA 92505 REV.# BY DATE DESCRIPTION Qa,namasu$ SOLAR DWG TITLE: PAGE #: SCALE: SITE LOCATION: INDIVIDUAL 4677 Ber,CO Street 8 24865 COLDWATER CANYON TRAIL Boulder, 0004 PLOT PLAN I/16°= I'-0' MENIFEE.CA 303.447.0300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY QTY I MANUFACTURER MODEL NOTES TRADE 1 9 1 LG LG320NIK-A5(320W) PV MODULE SOLAR 2 9 ENPHASE IQ6PLUS-72-ACM-US PV INVERTER SOLAR 3 1 ORBIT 2DB75-5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR.120V SOLAR 6 1 ENPHASE X-10-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER. I X 20A-2P, I X 5A.IP SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 10 1 TBD TBD 1 UTILITY METER. IPH, 120/24OV,200A BLDR. ELEC. II 1 TBD TBD GROUNDING ELECTRODE,UFER BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL HER. CUTLER-HAMMER TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 BUS RATING. AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(320W) I.I7A x 9(1ODS)= 1a53A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(DC) 320 10.53A x I.25= I3A6A PEAK OUTPUT POWER STC (P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 2OAl2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) Z40/211-264 NOMINAL OUTPUT CURRENT(AC) AC MODULE SPEC AMPS(AC) 1.17 NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC UL1741 / IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. OTY BO OTY 9 BRANCH CIRCUIT OUTPUT. IMAXBC 0Ac-MOD.QTY SO) AMPS(AC) 10.53 AC MODULE QUANTITY, TOTAL MOD. QTY T OTY 9 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD. QTY T) AMPS(AC) 1 10.53 CONDUCTOR SIZING CALCULATIONS U CONDITION OF USE (COU): (AMPACITY•TEMP. DEBATE• FILL DERATE)Vs. REO'D(TMAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS. REO'D,(IMAX- 1,25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD TYPE DERATES DEBATE DERATE (A) (A) USED(A) A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.53 TERM 25 25 13.16 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 20 C #ID CU NM-B. COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL TYPE LOCATION TRADE A 1-#12 ENPHASE 0 CABLE. 1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10, H#10 EGC I CU I NM-8(ROMEX) I INTERIOR I SOLAR 10 C 1 3-#10, I-#IO EGC I CU I NM-B(ROMEX) I INTERIOR ISOLAR O © 9 ±ENIFEE 5 — o BA,IP © AND SA FE1 0 0 0 IN ROVAL 7 zGAiz G ' G BY ROOF EXTERIOR-GARAGE plans shall P, ELECTRICAL DIAGRAM 2.BBOKW LOT#96 :lation of any WOODSIDE HOMES: ORIGINAL BY:BRI MORRIS DATE:I7.07.II manes, f: DAKOTA AT AUDIE REVIEWED BY:JIM PARKS DATE:IZ07.11 flon. 1187O PIERCE STREET,SUITE#IOd MURPHY RANCH RIVERSIDE, CA 92505 REV.# BY DATE DESCRIPTION QO namasbd SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4571&O DO 8 304 PLOT PLAN 2 NITS24865 COLDWATER CANYON TRAIL Boulder,. 780 04 ELECTRICAL MENIFEE,CA 303.49T.0300 INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, APRIL 2016 EDITION 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(*")SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO:INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. 11)BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRT ). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL17G3. IEC61646. IEC61730. 8)CONDUIT AND.CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;"OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19) INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. DEPARTMENT _!b-I-Lo—] ued to be a perrr ft for,o ofthefederal suteorch DAKOTA AT AUDIE WOODSIDE HOMES. REVIEWEDINAL BYBRMPARRKIS DATE17.07.111 roved plansmust kept 11870 PIERCE STREET.SUITE#100 MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION • s dinamasy.Q SOUR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroaB y Street INDIVIDUAL 24865 COLDWATER CANYON TRAIL Bmider,CO 60304 PLOT PLAN 3 SITS MENIFEE,CA NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. TRANSI S I MIRE iRGNSIn(MOER�y)Y) PV.D6T.W E.REAIQG-G< E NILIiY METER B MLIN BEWRU 1. LVfRIfIF➢BY BVILDEAJ 4f COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQUIPPED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 10.53A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL SY:BRI MORRIS DATE:17.07.11 Lill DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS I DATEI7.07.11 11870 PIERCE STREET,SUITE#100 MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION Qd namasGe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 24865 COLDWATER CANYON TRAIL BwIdw,GO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS