Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-02909
City of Menifee Permit No.: PMT17-02909 29714 HAUN RD.ACCEL/-> MENIFEE, CA92586 Type: Residential Electrical MENIFEE Date Issued: 0 8/2 812 01 7 PERMIT Site Address: 24644 ROUND MEADOW DR, MENIFEE, Parcel Number: 358-660-001 CA 92584 Construction Cost: $7,626.24 Existing Use: Proposed Use: Description of SOLAR TR 32025 DAKOTA 9 MODULES, 9 MICROINVERTERS,2.880KW LOT 1 Work: Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET, SUITE 250 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number: 1001133 SUNSTREET ENERGY GROUP LLC 6531 IRVINE CENTER DRIVE,#200 IRVINE, CA Phone: 9494505840 Fee Description O,yt Amount(SI Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE 08/10/2017 PERMIT/PLAN CHECK NUMBER PMT17-04?M TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY El MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: [-]ADDITION []ALTERATION [-]DEMOLITION [Z]ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK 2.88kW ROOF MOUNTED PV SYSTEM PROJECTADDRESS 24644 ROUND MEADOW DRIVE,MEN IFEE, CA 92584 ASSESSOR'S PARCEL NUMBER 358-660-001 LOT 1 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION $ $7,626.24 {/ SO FT�200 L SQ FT 11 �k } APPLICANT'S SIGNATURE , / L DATE 08/10/2017 �rny STAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NU V BER BUILDING PLANNING ENGINEERING FIRE GREEN , SMIP INVOICE ^Ml� ) PAID AMOUNT } AMOUNT QC'I :/• OCASH OCHECK# CCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER G YES 0 NO City of Menifee Building 9,Scfety Department 29714 Hour,, Rd. Menifee, CA 92595 951-572-5777 WWW.cityafrnenifee.uS frspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM QTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.880 ON LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS. LG LG320NIK-A5(320W) BUYER: _ INVERTER 1 9 PCS.1 ENPHASE I IQ6PLUS-72-ACM-US ROOF TYPE I CONC. TILE DATE: - SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 ARRAY#4 MOD GTY 9 NA NA NA BUYER: —-------- - - TILT I8° NA' NA' NA° DATE: AZIMUTH 167° NA' NA. NA° - - - _----- ------ City of Menifee Building & Safety Dept. AUG 17 2017 O Received SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) :o CITY r PV AC DISCONNECT BU1L 1NI EXTERIOR-GARAGE UTILITY METER 8 PLAN AF MAIN SERVICE PANEL (VERIFIED BY BUILDER) _. AC COMBINER BOX REV E% 30'-2'ARRAY 5'-II" •pppr a1tY �r appa Of, regul ' jow It unti NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 4 ELEVATION A-LEFT ORIENTATION I LOT# I WOODSIDE HOMES: ORIGINAL BY:DUSTIN LANNING DATE:17.07.05 DAKOTA AT AUDIE 11870 PIERCE STREET,SUITE#100 REVIEWED BY:JIM PARKS I DATE:17.07.06 MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION ama10U V ..roue DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Bma ay Street INDIVIDUAL 24644 ROUND MEADOW DRIVE Balder,GO 80304 PLOT PLAN 1/16'= 1'-0' MENIFEE,CA 303.447.030D SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY I MANUFACTURER MODEL NOTES TRADE 1 9 1 LG LG320NIK-A5(320W) PV MODULE SOLAR 2 9 ENPHASE 106PLUS-72-ACM-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE 10 ENVOY ENV-IQAMI-240 PV DATA MONITOR, 120V SOLAR 6 1 ENPHASE X-IQ-AMI-240-B AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER,I X 20A-2P, 1 X 5A-IP SOLAR 8 I CUTLER-HAMMER TBD PV BREAKER.I X 20A-2P.RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 10 1 TBD 1 TOO 1 UTILITY METER, IPH.120/24OV,200A BLDR. ELEC. II 1 TBD TBD GROUNDING ELECTRODE,LIFER BLDR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE,CA PANEL MFR. CUTLER-HAMMER TEMP,AMBIENT HIGH(THAR) ASHRAE 2% °C 37 BUS RATING AMPS 200 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 200 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 40 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALLS: MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(320W) 1.17A x 9(MODS)= 10.53A OF CURRENT MOD. POWER.STC(P) AC MODULE SPEC WATTS(DC) 320 10.53A x 1.25= 13.14A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 1 TIE-IN WITH A 2BA12F 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC i WATTS(AC 280 NOMINAL VOLTAGE / RANGE AC MODULE SPEC VOLTS(AC) 240/ 211-264 NOMINAL OUTPUT CURRENT(IAC) AC MODULE SPEC AMPS(AC) 1J7 NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC U1_1741 / IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD.OTY Bc QTY 9 BRANCH CIRCUIT OUTPUT, IMAXBC (IAC°MOD.QTY BC) AMPS(AC) 10.53 AC MODULE QUANTITY,TOTAL MOD.OTY T OTY 1 9 TOTAL SYSTEM OUTPUT MARTSOAC•MOD. CITY T) I AMPS(AC) I0.53 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY° TEMP. DEBATE' FILL DEBATE)VS. REQ'D(MAX) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs. REO'D,(IMAX - 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W70 TEMP. I FILL RESULT I RED'D OCD TYPE DERATES DERATE IDERATE (A) (A) USED(A) A #12 CU I THWN-2 COU 30 0.76 1.0 22.80 10.53 TERM 25 25 13.16 20 B #10 CU NM-B COU 40 0.91 1.0 36,40 10.53 TERM 35 35 13.16 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 10.53 TERM 35 35 13.16 2D MFEL CONDUCTOR SCHEDULE KEY CONDUCTORS CU7AL TYPE LOCATION TRADE 10 ND SAFE [ p -#12 ENPHASE Q CABLE, 1-#6G, FREE AIR CU TC-ER ARRAY SOLAR B 3-#10.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR ® AL C 3-#10.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR 0 © po 5 m 0 Q V Al SA/IP O O 0W O O 20A/ ' 2oA/2P '8 ty s shall not tons G G G y viorati n of arty pr vision 6ord'mances. TM se t of ap )mpletion. I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.88OKW LOT#I ORIGINAL BY:DUSTIN LANNING I DATE:17.07.05 DAKOTA AT AUDIE WOODSIDE HOMES:11870 PIERCE STREET,SUITE#100 REVIEWED BY:JIM PARKS I DATE:17.07.06 MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE I DESCRIPTION b namasGe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 24644 ROUND MEADOW DRIVE Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.03M ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL. APRIL 2016 EDITION 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(})SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES.(2)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. IU BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- 0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NI 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS.WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- PA E 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED.EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- I9)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. 'd tote a pen the h dew,s )red Nis ,mg ORIGINAL BY:OUSTIN LANNING DATE17.07.05 DAKOTA AT AUD I E WOODSIDE HOMES REVIEWED BY:JIM PARKS DATE17.07.06 11870 PIERCE STREET,SUITE#100 MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION d nI DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4571 Boulder, G Street PLOT PLAN 3 NTS 24644 ROUND MEADOW DRIVE BO W13.4A080304 NOTES MENIFEE,CA 307.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. SOLPUECX WIRF iR4NBITICN 00X RNUER G9VAY) W M B�B<QYNfti EXiERICR-LiHG4F .LITY METEfl R !WN SERVICE PMiEL (VERIFIEp BY BXLLB'p. ) 4C COYdIXER W% SERVICE BY QUALIFIED PERSONNEL ONLY IT CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS PHOTOVOLTAIC SYSTEM EQI�JgPjED AC OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN AC OPERATING CURRENT: 8. 10A I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DUSTIN LANNING DATE17.07.05 DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS I DATE.17.07.06 11870 PIERCE STREET,SUITE 0I00 MURPHY RANCH RIVERSIDE,CA 92505 REV# BY DATE DESCRIPTION Vnamast6 EOLse DWG TITLE: PAGE k: SCALE: SITE LOCATION: 401 Broadway Street INDIVIDUAL 246"ROUND MEADOW DRIVE Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0" PLACARDS