PMT17-02907 City of Menifee Permit No.: PMT17-02907 29714 HAUN RD. �ACCELA-? MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 08128/2017 PERMIT Site Address: 24620 ROUND MEADOW DR,MENIFEE, Parcel Number: 358-660-003 CA 92584 Construction Cost: $6,778.88 Existing Use: Proposed Use: Description of SOLAR TR 32025 DAKOTA 8 MODULES, 8 MICROINVERTERS,2.560KW LOT 3 Work: Owner Contractor WOODSIDE HOMES SUNSTREET ENERGY GROUP LLC 11870 PIERCE STREET, SUITE 250 760 NORTHWEST 107 AVENUE RIVERSIDE, CA 92505 MIAMI, FL 33172 Applicant Phone:3054854110 KRISTEN MURRAY License Number. 1001133 SUNSTREET ENERGY GROUP LLC 6531 IRVINE CENTER DRIVE,.#200 IRVINE, CA Phone:9494505840 Fee Description gyt Amount 1$1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee•Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 ABUILDING & SAFETY PERMIT/PLAN CHECK PPLICATION Menifee DATE 08/10/2017 PERM IT/PLAN CHECK NUMBER PMT17- TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME POOL/SPA []SIGN SUBTYPE: ❑ADDITION []ALTERATION ❑DEMOLITION [Z]ELECTRICAL [-]MECHANICAL [:]NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK 2.56kW ROOF MOUNTED PV SYSTEM PROJECT ADDRESS 24620 ROUND MEADOW DRIVE,MENIFEE, CA 92584 ASSESSOR'S PARCEL NUMBER 358-660-003 LOT 3 TRACT 32025 PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE STREET SUITE 250 PHONE (949)939-9564 EMAIL MIKEJ@WOODSIDEHOMES.COM APPLICANT NAME KRISTEN MURRAY ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S NAME SUNSTREET ENERGY GROUP LLC OWNER BUILDER? ❑YES❑J NO BUSINESS NAME SUNSTREET ENERGY GROUP LLC ADDRESS 6531 IRVINE CENTER DR SUITE 200 PHONE (949)450-5840 EMAIL KRISTEN.MURRAY@SUNSTREET.COM CONTRACTOR'S STATE LIC NUMBER 1001133 LICENSE CLASSIFICATION B VALUATION$ $6,778.88 SQ FT 200 L SO FT APPLICANT'S SIGNATURE "4i'dt 'n' M DATE 08/10/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN 1 SMIP INVOICE AMOUNT PAID AMOUNT . /..n V�c� 0 CASH %'CHECK# 0 CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT OCASH OCHECK# 0 CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES 0 NO DL NUMBER NOTARIZED LETTER O YES Q NO City of Menifee Building &Scfety Department 29714 Hour. Rd. Menifee, CA 92586 951-672-6777 WW '.Cityofinenifee.11s Inspection Request Line 951-24F.-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.56DKW I I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8 PCS.j LG I LG320NIK-A5(320W) BUYER: INVERTER 8 PCS.1 ENPHASE I 106PLUS-72-ACM-US ROOF TYPE CONC. TILE DATE: _ SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 8 NA NA NA BUYER: — - TILT 1 18° 1 NA" I NA' NA' AZIMUTH 166° NA' NA' NA' DATE: City of Menlfee Bullding & Safety Dept. All II "' Receive SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) ' M PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 CITY OF MENI EE MAIN SERVICE PANEL (VERIFIED BY BUILDER) fi .JfLDING AN Si AC COMBINER BOX 3' 26'-10'ARRAY PLAN APPRO AL UV'1EWED BY A Approval of these plan shall approval of,arty violatic n of a regulations and ordinar ces. 1 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF jobsite until Mpletior. PLAN 2 ELEVATION B-LEFT-OPT ORIENTATION I LOT#3 ORIGINAL BY:DUSTIN LANNING DATE:17.07.05 DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS DATE17.07.06 11870 PIERCE STREET,SUITE#100 MURPHY RANCH RIVERSIDE,CA 92505 I DATE DESCRIPTION •� la namasG6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 24620 ROUND MEADOW DRIIVE 4571 Bouldder,CO CO 80304 PLOT PLAN /Ifi"=I'-0" MENIFEE,CA 303.447.03M 300 SYSTEM LAYOUT ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 8 LG LG320NIK-A5(32OW) PV MODULE SOLAR 2 8 ENPHASE 106PLUS-72-ACM-US PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0766-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG22IURB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE IQ ENVOY ENV-IQAMI-240 PV DATA MONITOR,120V SOLAR 6 1 ENPHASE X-10-AMI-240-8 AC COMBINER BOX SOLAR 7 1 ENPHASE TBD PV BREAKER.I X 20A-2P, I X 5A-IP SOLAR 8 1 CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,RATING MAY VARY SOLAR 9 1 TBD TBD SERVICE PANEL,200A BUS BLDR. ELEC. 10 I TBD TBD UTILITY METER, IPH,120/24OV,200A BLDR. tEl II TBD TBD GROUNDING ELECTRODE.UF BL ER DR. ELEC. AC MODULE SPECIFICATIONS AND CALCULATIONS INTERCONNECTION CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM UNIT PANEL LOCATION MENIFEE, CA PANEL HER. CUTLER-HAMMER TEMP,AMBIENT HIGH (TMAR) ASHRAE 2% °C 37 BUS RATING AMPS 1 200 TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 MAIN DISCONNECT AMPS 206 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 ALLOWED PV PER NEC AMPS 1 40 TEMP,DELTA LOW(TOELTA) TMIN-TTEST °C -27 PV OCPD DEVICE USED AMPS 1 20 MOD. MANUFACTURER AC MODULE SPEC LG INTERCONNECTION CALCS: MOD. PART NUMBER AC MODULE SPEC LG320NIK-A5(320W) INA x B(MODS)= 9.36A OF CURRENT MOD. POWER STC(P) AC MODULE SPEC WATTS(00) 320 9.36A x 1.25= II.70A PEAK OUTPUT POWER STC(P) AC MODULE SPEC WATTS(AC) 290 TIE-IN WITH A 20A/2P 2 SPACE PV BACKFEED BREAKER MAX CONTINUOUS OUTPUT POWER STC(P) AC MODULE SPEC I WATTS(AC) 280 NOMINAL VOLTAGE/RANGE AC MODULE SPEC VOLTS(AC) 240/211-264 NOMINAL OUTPUT CURRENT OAW AC MODULE SPEC AMPS(AC) J7 NOMINAL FREQUENCY/RANGE AC MODULE SPEC Hz(AC) 60/59.3-60.5 OUTPUT PHASE QUANTITY AC MODULE SPEC PHASE I COMPLIANCE AC MODULE SPEC ULI741/ IEEE1547 GROUNDING AC MODULE SPEC ISOLATED MAX BRANCH CIRCUIT OCPD AC MODULE SPEC AMPS(AC) 20 AC MODULE QUANTITY,MAX PER BRANCH CIRCUIT MOD. QTY Be QTY 8 BRANCH CIRCUIT OUTPUT, IMAXBC (IAC'MOD.QTY Be) AMPS(AC) 9.36 AC MODULE QUANTITY,TOTAL MOD. OTY T QTY 8 TOTAL SYSTEM OUTPUT IMAXTS (IAC'MOD.QTY T) AMPS(AC) 1 9.36 CONDUCTOR SIZING CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY ° TEMP. DERATE'FILL DEBATE)vs.REO'D(IMAx) 2)TERMINALS(TERM): AMPACITY AT TERMINALS. Vs. REO'D.(IMAx ' 1.25) KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D COD TYPE DERATES DERATE DERATE (A) (A) USED(A)A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.36 11 TERM 25 25 11.70 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.36 TERM 35 35 11.70 20 C #10 1 CU I NM-B COU 40 0.91 1.0 36.40 9.36 TERM 35 35 11.70 20 CONDUCTOR SCHEDULE o KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENPHASE Q CABLE, 1-#6G,FREE AIR CU TC-ER ARRAY SOLAR MO N DEI B 3-#10, 1-#10 EGG CU NM-B(ROMEX) INTERIOR SOLAR C 1 3-#10, 1-010 EGG CU I NM-B(ROMEX) I INTERIOR ISOLAR 9 5 O4 5A/IP OO O 29A/ O 20A/2 �N G G he ca Istruei A e C C = 11 )roVisk ns of 1 I I I set of ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.560KW LOT#3 ORIGINAL BY:DUSTIN LANNINO DATE:17.07.05 DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS DATE:17.07.06 11870 PIERCE STREET.SUITE#100 MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY I DATE I DESCRIPTION d namaste DWG TITLE: PAGE# MAR : SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 24620 ROUND MEADOW DRIIVE Boulder,GO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL INSTALLATION NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW,TO MAXIMUM EXTENT POSSIBLE, 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 6)THE RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL, APRIL 2016 EDITION 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(})SPACE BETWEEN PV MODULES, SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE EDGE OF THE PV.ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 9)PV PANEL HAS BEEN TESTED BASED ON UL 1703. 10)AN ANIMAL GUARD SHALL BE INSTALLED AROUND THE PERIMETER OF EACH PV ARRAY IN SUCH A WAY AS TO MAINTAIN THE MODULE MANUFACTURER'S WARRANTY. IU BASE ATTACHMENT AND FLASHING TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 12)ALL ROOF ATTACHMENTS TO BE FLASHED AND SEALED PER MANUFACTURER'S SPECIFICATIONS. ELECTRICAL NOTES: GENERAL- I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703. IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. SIGNAGE- 15)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 16)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 17)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERIAT EN MINIMUM HEIGHT t. ,, 18)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 19)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. bea R _l pwm In am be ORIGINAL BY:DUSTIN LANNING I DATE17.07.05 DAKOTA AT AUDIE WOODSIDE HOMES REVIEWED BY:JIM PARKS DATE17.O7.Ofi 870 PIERCE STREET,SUITE#100 MURPHY RANCH RIVERSIDE,CA 9Z505 REV.# BY DATE DESCRIPTION txmasGB so��v DWG TITLE: rPAGE [N'T ALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 246ZO ROUND MEADOW DROVE Boulder,GO 80304 PLOT PLAN S MENIFEE,CA 303,447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 7 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) AC COMBINER BOX SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE — AC SPECS )A A PHOTOVOLTAIC SYSTEM EQUIPPED C OPERATING VOLTAGE: 240 V WITH RAPID SHUTDOWN it an AC OPERATING CURRENT: 7.20A 0 ,ton he I PC., NEC 690.54 1 PC., NEC 690.12 NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:DUSTIN LANNING DATE:17.07.05 DAKOTA AT AUDIE WOODSIDE HOMES: REVIEWED BY:JIM PARKS I DATEd7.07.06 11870 PIERCE STREET,SUITE#100 MURPHY RANCH RIVERSIDE,CA 92505 REV.# BY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Brw"ay Street INDIVIDUAL 24620 ROUND MEADOW DRIIVE BmldK,,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS