Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01938
City of Menifee Permit No.: PMT17-01938 29714 HAUN RD. "!►CCEL/k� MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 06/2 912 0 1 7 PERMIT Site Address: 29097 MORAGA ST,MENIFEE, CA 92584 Parcel Number: Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR MODEL TR 31582 HERITAGE HEIGHTS Work: 8 MODULES,2.12 KW LOT 120 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description 9.9C Amount lSl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING . PERMIT/PLAN APPLICATION 4,•T ' - Menifee DATE 06/06/0207 PERMIT/PLAN CHECK NUMBER �� 1 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [-]SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW [-]PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1874-2.12kW/8 PCS Master Solar Permit No.:PMT17-00129 PROJECTADDRESS 29097 Moraga St.,Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER LOT 120 TRACT 31582 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr., Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879 PHONE (951)8173680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION nIT Z SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 06/06/2017 CITY STAFF USE O�INLYL' DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP V INVOICE AID AMOUNT AMOUNT OCASH OCHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-572-6777 www.cityofinenifee.Us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. I MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.t2GKW I I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8 PCS.1 HYUNDAI I HISG(265W) BUYER:_ i o o f-ME IFE INVERTER 8 PCS. ENPHABE M215-60-25-60-2LL-S22-IG - ROOF TYPE I CONC,TILE DATE: _ SUB-ARRAY INFORMATION BUILDING At D , ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4 MOD OTY 8 NA I NA NA City Of menifee BUYER: —�`'` �T-A-PPIZ VA TILT 18° NA' NA' NA' AZIMUTH 262° 1 NA' I NA' I NA' Building Dept DATE: JUN I b 2017 REVIEWED 4— Re c e i v e d *Approval of these plarissi 3' 5'-5' approval of,any viol tion( regulations and ordh iance jobsite until comple an. .. a f W W N i - SOLADECK WIRE O TRANSITION BOX ( (UNDER ARRAY) PV DISCONNECT EXTERIOR-GARAGE w UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1874 ELEVATIONS-RIGHT ORIENTATION 3 LOT#120 N HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER I DATEJ7.04.07 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE:17.04.07 CORONA.CA 92879 REV.# I BY DATE I DESCRIPTION SOI�K DWG TITLE: PAGE#: I SCALE: tkmae;U6 SITE LOCATION: INDIVIDUAL 29097 MORAGA STREET a571 BaultlereCO 0300et PLOT PLAN 1 I/16'=I'-0' MENIFEE,CA OOBA47.0800 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE /CALL UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AD) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(00 48 TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(Dc1 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(Da1 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DO 31.30 INV. GROUNDING INVERTER SPEC ISOLATED ft MOD. OPEN CCT.VOLTAGE(V00 MODULE SPEC VOLTS(Dc) 38.10 INV. OTY.MAX/ BRANCH CCT. INV Ty`. OTY 8 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT.IMAXBC (IACINV.OTYac) AMPS(AC) 7.20 MOD. MAX VOLTAGE(VMAXM00) (VOC♦(TO'COEF)) VOLTS(oc) 41.18 INV.QUANTITY,TOTAL INV.OTYT OTY 8 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(Dc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IACINV.QTYT) AMPS(AC) 7.20 MOD. SHORT CCT.CURRENT(ISC) MODULE SPEC AMPS(DO 9.00 MOD. MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(00 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(DC) 14,06 lOt a COt SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) IS ELECTRICAL EQUIPMENT SCHEDULE yp OVj5j0 KEY QTY I MANUFACTURER MODEL NOTES TRADE ,)i$ et of I 8 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 a ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER OG221URB PV AC DISCONNECT.NEMA 3R.24DV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK 8 XX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x 15A-IF(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLLODR.ELEC. II 1 780 TBD UTILITY METER,IPH, 120/240V.200A BB.ELEC. 12 I TBD I TBD I GROUNDING ELECTRODE LIFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE (COO): (AMPACITY• TEMP.DEBATE °FILL DEBATE) VS.REO'D(IMAX) ITEM UNIT I PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS.REO'D,(IMAX- 1.25) PANEL MFR. I CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DEBATES DEBATE .DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 7.20 ALLOWED PV PER NEC AMPS 40 TERM 25 25 9.DO 20 PV OCPD DEVICE USED AMPS 20 e #10 cu NM-B COU 4D 0.91 1.0 36.40 7.20 INTERCONNECTION CALCS: TERM 35 35 9.00 20 0.9A x RMODS)= 7.20A OF CURRENT L #10 CU NM-B COU 40 0.91 I.0 36.40 17.20 ]2DA x I.zs• 9.00A TERM 35 35 9.00 20 TIE-IN WITH A 2DA/21 2 SPACE PV BACKFEED BREAKER CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A -#12 ENGAGE CABLE, 146G,FREE AIR I CU I TC-ER I ARRAY I SOLAR B 3-#10, I-#10 LOU I CU I NM-B(ROMEX) I INTERIOR I SOLAR 5 © II C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR 0 CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR 70 e M — SEE NOTE I5 10 8 ISA/IP O O O 30 204/2P 3 L N hA B C = 12 I I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.120KW LOT# 120 HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER I DATE:I7.OL.07 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE:17.04.07 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •is namaste DWG TITLE: PAGE#: SCALE: sDixB SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29097 MORAGA STREET PLOT PLAN 2 NTS MENIFEE,CA Bd303.46 CO 0300� ELECTRICAL STRUC URAL NOTES- SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. n p� 6)THE UNIRAC SOL 27.3.RMO P T RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION I" Il MANUAL.VERSION 227.3:PUB 140113-ICC,JANUARV 2014, 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH C z)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY, 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- O DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV SHALL BE ROOFED WITH ITION LE UNLESS PV ARRAY SHALL RUN FROM ABOVE THE PVVARRAY TO THE ROOF EAVEOTILE SINSTALLED BELOW THE ARRAY TOIBE INSTALLED ABOVE THE ECIFIED TO HE LCOMPOS LED T ON ROOCOMPOSITION PER ROOFER SHINGLE 4 6)BCRDISTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. th fade BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. )ve plan ELECTRICAL NOTES GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 1D)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IL)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED TINDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250-122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k- 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110,26. HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER DATE17.04.07 980 MONTECITO DRIVE,*302 REVIEWED BY:JIM PARKS I DATE17.04.07 CORONA,CA 92879 REV,# BY DATE I DESCRIPTION DWG TITLE: PAGE A: SCALE: S a namasGe INDIVIDUAL SITE LOCATION: =6 PLOT PLAN 3 NTS 29097 MORAGA STREET d571 Beaetlway Street NOTES MENIFEE,CA Boultlar,C080304 303.gd].0300 CAUTION: MT POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. �l r 'or,or eordty be kept on th SOLADECI(WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 7.20A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION HERITAGE HEIGHTS LENNAR: ORIGINAL BY:HIM ABCOUWER DATE:17.04.07 980 MDNTECITD DRIVE,9302 REVIEWED BY:JIM PARRS OATE0.04.07 �� CORONA,CA 92679 REV.# BY DATE DESCRIPTION DWG TITLE: JP7# CALE: Q'ar1amastd INDIVIDUAL SITE LOCATION:PLOT PLAN 29097 MDRAGA STREET 4571 Broadw y Street PLACARDS MENIFEE,CA Boulder,CO 80304 303.447.0300