PMT17-01937
City of Menifee Permit No.: PMT17-01937 29714 HAUN RD. <ACCELA7. MENIFEE,CA 92586 Type: Residential Electrical ... """"',.. MENIFEE Date Issued: O6/29/2017 PERMIT Site Address: 29083 MORAGA ST, MENIFEE,CA 92584 Parcel Number: Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR MODEL TR 31582 HERITAGE HEIGHTS Work: 12 MODULES,3.18 KW LOT 119 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description 01t r Amount fEl Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pepnit_Templale.rpt Page 1 of 1 BUILDINGAPP • w .'""Menifee DATE 06/06/0207 PERMIT/PLAN CHECK NUMBER ' TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION []ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING [I RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2686-3.18kW/12 PCS Master Solar Permit No.:PMT17-00129 PROJECT ADDRESS 29083 Moraga St.,Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER LOT 119 TRACT 31582 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL )eremiah.acayturri@lennar.com APPLICANT NAME Lerner Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lerner Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lerner Homes of Callfornia, Inc. ADDRESS 980 Montecito Dr.,Suite302,Corona.,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ OI „2 SQFT LSQFT APPLICANT'S SIGNATURE DATE 6/2017 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION �ia'1 CITY OFMENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE AMOUNT PAID AMOUNT 0CASH 0 CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCAS. O{HECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED O YES 0 NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92585 951-672-6777 www.cityof rnenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION ITEM OTY MFR. MODEL BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.I8O KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS. HYUNOAI HIS-S266RG(265W) INVERTER i2 PCS. ENPH45E M215-6O2 - 65W BUYER: ROOF TYPE CONC. TILE SUB-ARRAY INFORMATION DATE: ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 _ MOD CITY 12 NA NA NA BUYER: CITY F TILT 23° I NA- NA' NA' -- AZIMUTH ISO° NA° NA' NA' OATS:_ IN City of ltenifee Building Dept PLAN F JUN 16 2017 �/�" 61Y,�/p�� REVIE I 1 c 3 '�d' 1 V FJ 'Approval of 0 approval ,an regulation and jobsite un it cm 'a a ( SOLADECK WIRE TRANSITION BOX r (UNDER ARRAY) O PV AC DISCONNECT EXTERIOR-GARAGE 1 UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) �U�)i d°yV ZZ0 NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION C-RIGHT ®\ ORIENTATION 4 LOT# 119 HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER DATE:IZO4.O7 980 MONTECITO DRIVE,#302 REVIEWED BY:UIM PARKS DATE:17.O4.O7 CORONA.CA 92879 REV.# BY DATE DESCRIPTION :INDIVIDUAL G TITLE: PAGE #: SCALE: `UP nOmastd SITE LOCATION: ae'eeT PLAN 1 29083 MORAGA STREET 4571 Broadway Street 1116"= I'-0" MENIFEE.CA Boulder,CO 8O3O4 TEM LAYOUT 3D3.447.O3OO MODULE SPECS AND CALCULATIONS INVERTER SPECS ITEM NOTE/CALC UNIT DETAIL ITEM AND CALCULATIONS LOCATION MENIFEE,CA INV. MAKE NOTE/CALC UNIT DETAIL TEMP,AMBIENT HIGH(Tn4X) ASHRAE INVERTER SPEC ENPHASE TEMP,AMBIENT LOW(TMIN) ASHRAE E%TR.MIN °L INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,MODULE TEST(TTEST) MODULE SPEC 2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS( 225 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS(9c) 48 M00.MANUFACTURER °C -27 INV. OUTPUT V.(VAC NO M) INVERTER SPEC VOLTS(A[) 240 MODULE SPEC HYUNOAI INV.OUTPUT FREQUENCY MOD. PART NUMBER MODULE SPEC HIS-5265RG INVERTER SPEC INV. OUTPUT CURRENT,I4c HERTZ 60 MOD.POWER STC(P) .MODULE SPEC WA775(Oc) 265 INVERTER SPEC AMPS MOD. POWER PTC MOOIAE SPEC WATTS(Oc) 238 INV. PHASE OU4NTITY INVERTER SPEC PHASE I ( MOD. OPERATING VOLTAGE(VMPJ MODULE SPEC VOLTS(OO) 31.30 COMPLIANCE INVERTER SPE[ ULI7GI/IEEEI547 MOD. OPEN CCT.VOLTAGE(VOCJ MODULE SPEC VOLTS(DD) 38.10 INV. pTOUND�ING BRANCH CCT. INV.p7ygR SPEC ISOLATE- fl MOD.COEFF. VOLT/TEMP(COEF) M00(AE SPEC V/°C -0.114 OTV 12 i MOD.MAX VOLTAGE(VMAxMOD) BRANCH CCT.OUTPUT.IMAx00 (IAC'INV.OTYBC) AMPS(AO) 10.80 (VDc+(T0•COEF)) VOLTS(Oc) 41.18 INV.QUANTITY,TOTAL MOD. OPERATING CURRENT(IMPJ MODULE SPEC AMPS(Oc) 8.50 INV.OTVT OTY 12 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(Oc) 9,pp T074L SYSTEM OUTPUT.IMAXTS (IAc•INV.QTYi) AMPS(4c) IO.BO MOD.MAXIMUM CURRENT(IMAx) (15C• 1.2$) gMPS(OC) 11.2$ MIN.AMPACITY REQ'D,PER NEC OnAX•L25) AMPS(DD) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(DD) IS ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES I 12 HYUNDAI HIS-SZ65RG (265W) PV MODULE TRADE 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK D786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR fans shall Ot h 4 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOI-AR ation of an pro 6 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 I TBD TBD CAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BO% SOLAR nances. s sel B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I%ISA-IP(ENVOY) SOLAR •IUn, 9 NOTE CUTLER HAMMER TBD PV BREAKER,I x 204-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER OLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS II TBD TBD UTILITY METER. IPH. 120/240V,200A BLOR.ELEC. 12 I TBD TBO GROUNDING ELECTRODE UFER BLOR.ELEC. CONDUCTOR SIZING CALCULATIONS BLOR.ELEC. D corlmnoN of USE(CDU): INTERCONNECTION CALCULATIONS 2)TERMINALS(TERM): (AMPACITY•TEMP. DERATE•FILL DEBATE) VS.REO'D(IMAX) ITEM AMPACITY AT TERMINALS. V5.REQ'D.(IMAX• 1.25) UNIT PANEL MCU/ALINSULATIONTION CALC' AMPACITY W/0 TEMP. FILL RESULT REO'D OCD PANEL MFR. CUTLER-HAMMER TYPE DERATES DERATE DERATE AMPS 200 COU (A) (�I'D 22.80 10.80TERM 25 25 13ALLOWED PV PER NEC AMPS 40 COU 0.91 1.0 36.GD 10.80 PV OCPD DEVICETERM 3s 35 13.so 20 INTERCONNECTION CALCS.-COU 40 0.91 1.0 36.40 10.60 0.9A x 12ftn)= 10,80A OF CDRREW TERM 35 35 13.50 20 10.80A x 1.25= 13.50A CONDUCTOR SCHEDULE TIE-IN WITH 2DA12P 25PACE PV BCCKFEEO BREAKER KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1412 ENGAGE CABLE, 1-#613,FREE AIR CU TC-ER I ARRAY ISOLAR B 3-#10.1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C I-#ID EGC CU NM-6(ROME%) INTERIOR SOLAR 5 CA75E © II 0 CAT5E,ETHERNET CABLE LU LATSE INTERIOR SOLAR 0- SEE NOTE 15 I 10 I54/IP O O O O 20A/2P G G N G__ A B C — 12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.IBOKW LOT#H9 HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER DATE:17.04.07 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:17.04.07 CORONA,CA 92879 REV.# BY DATE DESCRIPTION DWG TITLE: PAGE#: SCALE: namaste INDIVIDUAL SITE LOCATION: soles PLOT PLAN 2 NTS 29083 MORAGA STREET 0.571 B=ftay S00B1 ELECTRICAL MENIFEE,CA BOVlBeq CO 80304 303.447.0300 STRUCTURAL NOTES SOLAR CONTRACTOR- S)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48.O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE, 3)ROOF 4)SOLAD C WARE PENETRATIONS ASSOCIATED H TRANSITION BOXWILLBEINSTALLED SOLAR N PER(MANUFACTURE MANUFACTURER'S INSTRUCTIONS.OIT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3•ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 14D113-ICC,JANUARY 2014, 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. c /� ROOFING CONTRACTOR- DC AI U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING-SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK.BASE TO BE INSTALLED ONE FOOT(1')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. Ir 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. _rue'to b( s of he fec pro p'a ELECTRICAL NOTES GENERAL- 0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL403,IEC61646, IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SMALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.IB)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIMAB000WER DATEd7.04.07 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE17.04.07 CORONA,CA 92879 REV.# BY DATE DESCRIPTION OWG TITLE: PAGT* CALE: �1 rl(ir11QSG@INDIVIDUAL SITE LOCATION: t;6PLOT PLAN 3 Z9083 MORAGA STREET 4571 Broadway SBeet NOTES MENIFEE.CA Boulder,CO 803M 303.447,0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ]ENT Iitfor,oran l late or city st be kept on th TRANSITION R BADECX WIRE iRAN51TIRABOX (UNDER ARRAY) PV AC DISCONNECT EA7ERIOR GARAGE DTILITY METER 9 MAIN SERVICE PANEL (VERIFIED DY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.80A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION HERITAGE HEIGHTS ECDRONA, ORIGINAL BY:KIM ABCOUWER DATE:$7.04.07 TO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:I7.04.07 �� 92879 REV.# BY DATE DESCRIPTIONDWG TITLE: PAGE #: SCALE 4W14 namast;6INDIVIDUAL N: soLAE PLOT PLAN 4 NTS A STREET 4571 Broadway Street PLACARDS Boulder,CO 80304 303.447.D300