PMT17-01936 City of Menifee Permit No.: PMT17-01936
29714 HAUN RD.
<ACCELA-"? MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 0 612 912 01 7
PERMIT
Site Address: 28775 CEBELIA CIR,MENIFEE, CA Parcel Number:
92584 Construction Cost: $8,017.20
Existing Use: Proposed Use:
Description of SOLAR MODEL TR 31582 HERITAGE HEIGHTS
Work: 9 MODULES,2.92 KW
LOT 118
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description ptty. Amount($)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of enrors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
FBUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
."Menifee
DATE 06/06/0207 PERMIT/PLAN CHECK NUMBER (� I
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL []MECHANICAL
❑NEW ❑PLUMBING ❑RE-ROOF-N UMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2131 -2.92kW/9 PCS
Master Solar Permit No.: PMT17-00129
PROIECTADDRESS 28775 Cebelia Circle, Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER LOT 118 TRACT 31582
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California,Inc.
ADDRESS 980 Montecito Dr..Sulte 302,Corona, CA 92879
PHONE (951)817-3680
EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ 8 L SQ FT
APPLICANT'S SIGNATURE 6106/2017
DEPARTMENT DISTRIBUTION ^ CITY OFMENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGWERING FIRE GREEN SMIP
INVOICE v\�
AMOUNT ( AIDAMOUNT OCASH OCHECKN 0CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT
O CASH OCHECK JI OCRE0IT CARD VISA/MC
OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City Of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.citycfinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION
BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY 1 MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.915 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 9 PCS.1 HYUNDAI I HIS-S265RG (265W)
INVERTER 9PCS. ENPHASE M215-60-2LL-S22-IG BUYER:
ROOF TYPE CT NC.
TILE DATE:
SUB-ARRAY INFORMATION CITY OF MEN FEI
ARRAY#I ARRAY#2 ARRAY#3 ARRAY#4
TIL OTY 9 NA NA NA BUYER: AN)S
TILT 18° NA° NA° NA°
AZIMUTH 1 155° 1 NA° I MAD NA° DATE: _
City of ivtenitee PLAN PPRO
Building Dept 4 �
JUN 16 2017 REVIEWED
Received
5-5 , 'Approval Of these plans II In
approval of,any violation If any
regulations and ordinances This
jobsite until completion.
V
SOL
TRANSITION
WIRE
(UNNDERDER ARRAY)
BOX
AY)
PV AC DISCONNECT
( EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
CL
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2131 ELEVATION B-RIGHT ®�
ORIENTATION 4 LOT#118
HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER I DATE:17.04.07
980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:17-04.07
CORONA.CA 92B79 REV.* BY DATE 1 DESCRIPTION
• namasbe
DWG TITLE: AfPAGE*- CALE SITE LOCATION: oue
INDIVIDUAL 28775 CEBELIA CIRCLE4571 BroeOwey SheetPLOT PLAN /16'=P-O' MENWEE,CA Boulder,CO-----
SYSTEM LAYOUT 303.447.0300
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDc MAX) INVERTER SPEC VOLTS(00 48
ES
TEMP.DELTA LOW(TDELTA) TMIN-TTT °L 77 INV. OUTPUT V.(VAC NDM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(Ac) 0.9
MOD. POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTL MODULE SPEC WATTS(Dc) 238 COMPLIANCE INVERTER SPEC ULI741/IEEEI547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 31.30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD.OPEN OCT. VOLTAGE(Voc) MODULE SPEC VOLTS(oc) 38.10 INV. OTY.MAX/BRANCH OCT. INV.QTYBC OTY 9 D'
MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH OCT. OUTPUT,IMAXSC (IAC INV.OTYac) AMPS(AC) 8.10
M00. MAX VOLTAGE(Vnnxno0) (Voc t(To'CoEF)) VOLTS(DO 41AB INV.QUANTITY,TOTAL INV.QTYT QTY 9
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 B.50 TOTAL SYSTEM OUTPUT.IMAXTS I (IACm INV.QTYT) AMPS(AC) 8.10
MOD.SHORT OCT. CURRENT(ISO) MODULE SPEC AMPS(DC) 9.00
MOD.MAXIMUM CURRENT(]MAX) (Isc• 1.25) AMPS(DO) 11.25
MIN.AMPACITY REO'D,PER NEC (]MAX' 1.25) AMPS(oc) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY I GTY IMANUFACTURER MODEL NOTES TRADE
9 HYUNDAI HIS-S265RG(265W) PV MODULE SOS
2 9 1 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR Con rued
4 1 CUTLER-HAMMER OGE21URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR ision ofth
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR if ap rove(
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER.I X 20A-ZP,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 1 TBD TBO SERVILE PANEL,MIN. 125A BUS BLDR.ELEC.
It I TBD TBD UTILITY METER,IPH,120/24DV,200A BLDR.ELEC.
I2 I TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
O CONDITION OF USE(COL): (AMPACITY'TEMP.DERATE'FILL DERATE) VS.REO'D(TMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS, VS.REO'D,(InAx' I,25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/Al INSULATION CALL. AMPACITY W'/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 1 22.80 1 8.10 1ALLOWED PV PER NEC AMPS 4O
TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20
e x10 cu NM-B cou 4D o:91 1.0 36.40 8.10 INTERCONNECTION CALCS:
TERM 35 35 10.13 20 0.9A X 9(MDDS)= B.IDA OF CLRREW
C #10 CU NM-B COL 40 0.91 1.0 36.40 8.10 B.IOA x I.25= ID.I3A
TERM 35 35 IQ 3 20 TIE-IN WITH A 2oA/2P 2 SPACE PV BACKFEED BREAKER
CONDUCTOR SCHEDULE
KEY I CONDUCTORS I CU/AL I TYPE LOCATION TRADE
A I-#12 ENGAGE CABLE, I-#6G,FREE AIR CU TC-ER ARRAY SOLAR
B 3-0)10,I-#10 EGC CU I NM-B(ROMEX) I INTERIOR I SOLAR 115
C 54MO, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
D CAT5E,ETHERNET CABLESEE10SAAl(P
A/2P
'N
_J
A B C = 12
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2 915KW
LOT#118
HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER I DATE:17.04.07
980 MONTECITO DRIVE.#302 REVIEWED BY:JIM PARKS I DA7E:17.04.07
CORONA,CA 92879 REV.# BY DATE I DESCRIPTION •,
QU namaste
soue
DWG TITLE: PAGE*: I SCALE: SITE LOCATION;
INDIVIDUAL 4571 Broady Street
PLOT PLAN 2 NTS 28775 CEBELIA CIRCLE B001deq CO B0304
ELECTRICAL MENIFEE,CA 303A47.030D
STRUCTURAL N07ES:
SOLAR CONTRACTOR-
O ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3.PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(}')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES C2')BEYOND
THE EDGE OF THE PV ARRAY/SUB-ARRAY.
B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. `D ��
ROOFING CONTRACTOR- kR
Q DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING.FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION. .
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(17 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.COMPOSITION SHINGLE
SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER
SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.
BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION.
a ermit
ler,I,state
as i ust be
ELECTRICAL NOTES.
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730,
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
IB)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING, BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE IID.26.
HERITAGE HEIGHTS LENNAR: ORIGINAL BY:KIM ABCOUWER DATE17.04.07 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE)7.04.07
DWG TITLE: PAGE#: 1 SCALE: CORONA,CA 92879 REV.# BY DATE I DESCRIPTION tlimastd
SITE LOCATION;
SOLAR
INDIVIDUAL 20775 CEBELIA CIRCLE 4571 13
000.13304
81 r PLOT PLAN 3 NTS NOTES MENIFEE,CA 303.447.030D
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
_ V
Y
)n the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8. I0A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
HERITAGE HEIGHTS : ORIGINAL BY:KIM ABCOUWER DATE:17.04.07
980 MO
NTECITO DRIVE,R302 REVIEWED BY:JIM PARKS DATE:17.04.D7
80
CORONA,CA 92879 REV.* BY DATE DESCRIPTION
Qb namaste
$01AR
DWG TITLE: PAGE R: I SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 28775 CEBELIA CIRCLE
PLOT PLAN 4 NTS MENIFEE,CA Bo303.44 0300 4
PLACARDS