PMT17-01829
City of Menifee Permit No.: PMT17-01829 29714 HAUN RD. 4ACCELA— MENIFEE,CA 9258E Type: Residential Electrical MENIFEE Date Issued: O6I09/2017 PERMIT Site Address: 24920 COLDWATER CANYON TR, Parcel Number: 358-680-007 MENIFEE, CA 92584 Construction Cost: $16,000.00 Existing Use: Proposed Use: Description of SOLAR TR 32025 DAKOTA Work: 12 MODULES, 12 MICROINVERTERS LOT 74 Owner Contractor WOODSIDE HOMES OF CA SUNPOWER CORPORATION SYSTEMS 11870 PIERCE ST#250 77 RIO ROBLES RIVERSIDE, CA 92505 SAN JOSE, CA 95134 Applicant Phone: 9417203850 TYLER SANTANGELO License Number:890895 SUNPOWER CORPORATION SYSTEMS 77 RIO ROBLES SAN JOSE, CA 95134 Fee Description Oft Amount($) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 3.00 General Plan Maintenance Fee-Electrical 1 12.60 $295.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee. Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjurythat I am under provisions of With a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and 0I am exempt from licensure under the Contractors State License Law for Professions Code and my license is in full force and effect. the following reason: License Class q so PQ 1146iR I License No. By my signature below I acknowledge that,except for my personal residence Expires Signature l in which l must have resided for at least one year prior to completion of improvements covered by this permit.I cannot Iegallysell a structure that I WORKER'S COMPENSATION DECLA ION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable taw,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as providedfor this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which ,nww,leeinfa.ca.eov/calaw,html. this permit is issued. Po cy# Date I have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which o By my signature below I certify to each of the following:)am the property this permit Is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information 1 have provided is correct.I agree to comply Carrier �V L with all applicable city and county ordinances and state laws relating to AA� / t building construction.I authorize representatives of this city or county to Policy# {'UrU��� rExpires 1 I enter the above identified property for inspection purposes. (This section need not to be completed is the permit Is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT o I certify that in the performance of the work for which this permit is issued, /cYj /� Ishallnotemolov any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# 60 ay 11 workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith co I s rth ns. f Will the applicant or future building occupant handle hazardous material or Applicant rnR', ( mixture containing a hazardous material equal to or greater that the amounts sp¢¢cified on the Hazardous Materials Information Guide? WAR N._-,e FAIIUa SECUREWORKER'S COMPENSATION COVERAGE IS OYE X-0 a= UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District construction or modification checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES to Coast Airrli�Quality CONSTRUCTION LENDING AGENCY Dyes glNo I hereby affirm that under the penalty of perjury there is a construction Will the prop sed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer bou ary of a school? (Section 3097 Civil Code) 0 Yes o OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAOMD I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements underthe State of Contractors License Law for the reason(s)indicated below by the California Health al Safety Code,Sect' 5534 concerning checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 ha rdaus material reporti Business and Professions Code).Any city or county that requires a permit to es construct,alter,improve,demolish or repair any structure,prior to its Date /Y! ERTY OWNERO ORIZEDAGEN7 issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVA .REPAIR AND PAINTING IRRP) License Law(Chapter 9(commencing with Section 700D)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property ownen and property than($500). managers who do the paint-disturbing work them--elves or through their 01,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.eov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Finn Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No: completion,the Owner-Builder will have the burden of proving that it was not built or Improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: 0 I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETYPERMIT/PLAN CHECK APPLICATION m � JVlenifee DATE 06/05/2017 PERMIT/PLAN CHECK NUMBER ©I �/✓" TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [—]SIGN SUBTYPE: [—]ADDITION ❑ALTERATION ❑DEMOLITION ❑✓ ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Roofmount Solar Installation 4.02kW 12 Modules w/Micro-Inverters PROJECTADDRESS 24920 COLDWATER CANYON TRAIL ASSESSOR'S PARCEL NUMBER LOT 74 TRACT PROPERTY OWNER'S NAME WOODSIDE HOMES ADDRESS 11870 PIERCE ST.SUITE 250, RIVERSIDE, CA 92505 PHONE EMAIL APPLICANT NAME Tyler Santangelo ADDRESS 3979 E. Guasti Road, Suite B,Ontario, CA 91761 PHONE (951)303-5386 EMAIL tyler.santangelo@sunpowercorp.com CONTRACTOR'S NAME Neil DeLucenay OWNER BUILDER? ❑YES❑✓NO BUSINESS NAME SunPower Corporation,Systems ADDRESS 1414 Harbour Way South,Suite 1901, Richmond, CA 94804 PHONE . (941)720-3850 EMAIL neil.delucenay@sunpowercorp.com CONTRACTOR'S STATE LIC NUMBER 890895 LICENSE CLASSIFICATION B,C10, C46,A VALUATION$ $ 16,000.00 SO FT 210 L SQ FT APPLICANT'S SIGNATURE DATE 06/08/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION GIN OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP INVOICE PAID AMOUNT AMOUNT I O CASH OCHECKB OCREDITCARD VISA/MC PLAN CHECK FEES PAMAMOUNT I 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haul Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 NOTES:ROOFTOP PENETRATIONS AND/OR CONSTRUCTIONS NOT PERTAINING TO SOLAR INSTALLATION SHALL NOT BE LOCATED UNDER ARRAY. ARE 3'WIDE FIRE ACCESS PATH City of Menife Building & Safety Dept. 3' 21 JUN 0 9 2017 CITY OF MEN IFE BUILDING AN D SAFETY DEPARTMENT - - plece ved PLAN APPROVAL -- ---------------------- REVIEWED ` A E L I� CONCRETE 'Approval of these plans of be construe o bea permit for,or an_ TILE ROOF approval of,any violation o an provisions of th�federal,state or city V regulations and ordinanc S. Th s set Of approve plans mue kept on t e jobsite until completion. 5:12 JUNCTION BOX AA I/ Fiw� I —' — Q O ROOF ACCESS POINT / I I / 1 l I/I IA UTILITYAC DISCONNECT SWITCH 'I FROM(OUTSIDE E MAINAG SERVICE PANEL) SIGHT ° _ � SERVICE POINT ANO UTILITY METERING �— DRIVEWAY —3 3` TO ELECTRIC UTILITYGRID 12 MODULES SPR—X21-335—BLK—C—AC TILE HOOK FLAT TILE) INVISIMOUNT ABOVE TILE) PLAN 2 (SCHEME 1) ELEVATION B (4.02 kVI) °2u„ 6 non oocV„Exr*mE S U N P' WE R DAKOTA AT AUDY MURPHY RANCH —FLATLE INDIVIDUAL smEn wr OR PLOT PLAN CORPORATION, SYSTEMS FRONT ARRAY LAYOUT °xlExlxilOx 4.02 W 1414 HMONDR A9 SOUTH I81° 4.02RW „xwwx er xe45�au RICH MONO, CA 94804 [uSTtaxE„ srtE Faun«+ 2-STORlrvE 5:1 Prto� 7GENDRAN0 O 2-STORY 5:12 Dare (510) 540-0550 WOODS11870IER HOMES 24920 MENIFE ,CALIF ERIANYON9259 TRAIL sa.�. er„a, 11870 PIERCE ST.SUITE 250 MENIFEE,CALIFORNIA 92564 0 06-05-2017 sxEEr °, RIVERSIDE,CA 92505 APN*: 3 t 74 �E 3/32"