Loading...
PMT17-01697 City of Menifee Permit No.: PMT17-01697 29714 HAUN RD. Type: Residential Electrical <A-CCEL/-> MENIFEE,CA 92586 ,1"'" MENIFEE Date Issued: 06/13/2017 PERMIT Site Address: 30108 BRISTOL GATE LN,MENIFEE,CA Parcel Number: 364-380-062 92584 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES,2.65 KW LOT 199 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Appllcant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description 01t' Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Men'dee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_aldg_Permil_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION .,v Menifee �y DATE 05/03/2017 PERMIT/PLAN CHECK NUMBER 1� v TYPE: [I COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS Master Solar Permit No.: PMT14-02630 PROJECT ADDRESS 3010E Bristol Gate Ln ASSESSOR'S PARCEL NUMBER � —_950--0 62 LOT 199 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.eaytum@lennar.com APPLICANT NAME Lennar Homes of Califomia, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.aceyturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.ecayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION VALUATION$ $6,943.00 SO FT L SO FT APPLICANT'S SIGNATURE DATE 05/02/2017 a War— DEPARTMENT DISTRIBUTION a CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN �'� SMIP �• INVOICE (IV PAIDAMOUNT AMOUNT c"1 J• O CASH O CHECK# O CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Hqun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM I OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.650 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 10PCS. HYUNDAI HIS-S265ftG (2b5W) It of Menifee BUYER: -- INVERTER 10 PCS. ENPHASE M2I5-60-2LL-S22-IG y ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY Building Dept DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 1 ARRAY#3 juN AI 06 ZU�7 BUYER: MOD OTY 10 NA NA ��/ r TILT 23° NA' NM DATE: CITY Or EN AZIMUTH 172° NA' NA' Received BUILDIN AP PLAN AP RO REVIEWED B1 •Approval Pm I mgwafl u ally Nam jobsb until cm oft I i I ( I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) ri �a II -- "vr � PV DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 ' MAIN SERVICE PANEL (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF Z® PLAN I ELEVATION A-RIGHT ORIENTATION 2 LO # I99 ORIGINAL BY: KIM ABCOUNER DATE:I7.01.02 CAMELLIA AT LENNAR: 9 REVIEWED BY:SHAUN MARUNA DATE:17.01.03 THE LAKES CORONNA,A.C LA I DRIVE,#302 A CORONA. 92879 REV.# BY DATE DESCRIPTION J 01 KA 17.04.12 PLAN CHANGE �1)namasGe SUUR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30108 BRISTOL GATE LANE Boulder,CO 8030d PLOT PLAN 1 I716•=V-0' MENIFEE,CA 303."7.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(Be) 48 TEMP,DELTA LOW(ToELTA) THIN-TTEST •C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(Gc) 238 COMPLIANCE INVERTER SPEC UI-174111110M47 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DO 31.30 INV. GROUNDING INVERTER SPEC ISOLAT MOD. OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(oc) 38.10 INV. OTY.MAX/BRANCH CCT. INV,OTYeC OTY 10 OG MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V7•C -0.114 BRANCH CCT. OUTPUT.IMAXBC GAC'INV.GTY8C) AMPS(AC) 9.00 MOD.MAX VOLTAGE NMAXMO6) (Voc♦(To•COEF)) VOLTS(oc) 41.18 INV. QUANTITY,TOTAL I 1NV.QTYT OTY 10 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(oc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS I (IAC'INV.QTYT) AMPS(AC) 9.00 Al MOD.SHORT CCT.CURRENT(13c) MODULE SPEC AMPS(00 9.00 MOD.MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(oC) 11.25 MIN.AMPACITY REO'0.PER NEC (IMAX' 1.25) AMPS(DO 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS 00 15 ELECTRICAL EQUIPMENT SCHEDULE k12Q, KEY OTY MANUFACTURER MODEL I NOTES TRADE 1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 10 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3115 PV ROOF JUNCTION BOX,NEMA 3R SOLAR �L 4 1 CUTLER-HAMMER DG22JURB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR .hall wt 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TIED 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR of���MMUI aq Sofl 7 1 TBD TIED CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR L This set aFyyryi 8 NOTE CU AR �R'�•TLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x I5A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 20A-ZP.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TIE SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBO UTILITY METER.IPH,120/240V,200A BLDR.ELEC. 12 1 1 1 TBD TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY• TEMP. DEBATE• FILL DERATE) Vs.REO'D (IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM I AMPACITY AT TERMINALS. VS.REO'D,(IMAX• 1.25) PANEL MFR. I CUTLER-HAMMER HEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'0 BCD BITS RATING AMPS 200 TYPE DERATES BERATE BERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A M*12CUTHWN-2 COU 30 0.76 1.0 22.80 9.00 ALLOWED PV PER NEC AMPSTERM25 25 11.25 20 FV OCPD DEVICE USED AMPSB NM-B COU 40 0.91 1.0 36.40 9A0 TERM 35 35 1125 20 C NM-B I COU 140 0.91 1 LO 1 36.40 19.00 1r♦ TERM 1 35 1 1 1 35 111.25 1 20 CONDUCTOR SCHEDULE KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE, 146G,FREE AIR I CU TC-ER ARRAY SOLAR B 1 3-0 10.1- 10 EGG ICU I NM-B(ROMEX) INTERIOR SOLAR C 3410.1410 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR O D CAT5E.ETHERNET CABLE CU CAT5E INTERIOR SOLAR 5 6 II 7 o • O _ • SEE NOTE 15 0 0 O ISdIIP O O LZ°O 3 �N G G GJ A B C i 1 _ 12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2,650 KW LOT#199 ORIGINAL BY: KIM ABCOUWER DATE:17.01. LENNAR: 02 CAMELLIA AT REVIEWED BY:SHAUN MARUNA I DATE:17.01.03 980 MONTECITO DRIVE,#302 THE LAKES CORONA.CA 92879 RE . .BY DATE DESCRIPTION 01 KA 17.04.12 PLAN CHANGE namaste SaI..E DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway S6eel INDIVIDUAL 30108 BRISTOL GATE LANE Boulder,W BM04 PLOT PLAN 2 NTS MENIFEE,CA 303."7.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR.CONTRACTOR- O ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. A D ROOFING CONTRACTOR- ARTM NT U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 5% 2)26 GAUGE INTERLOCKING FLASHING SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. I )beapermi for,ora federal,stal or city plans must I a kept o ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY REECOGN12ED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 121 EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT, 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS, 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t- 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SMALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 11026. ORIGINAL BY: KIM ASCOUWER DATE:I . LENNAR: 01.02 CAMELLIA AT REVIEWED BY: SHAUN MARUNA DATE:17.01.03 980 MONTECITO DRIVE,*302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION 01 KA 17.04.12 PLAN CHANGE It imasbe xoux OWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmarmy Street INDIVIDUAL 30108 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. E SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) )e PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL ki (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.o A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: KIM ABCOUWER I DATE:I].01.02 CAMELLIA AT LENNAR: REVIEWED BY:SMAUN MARUNA DATE:17.01.03 CO NA,CA ITO DRIVE,#302 THE LAKES CORONA,CA 928]9 REV.# BY GATE DESCRIPTION 01 KA 17.04.12 PLAN CHANGE �b namaste sav DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4371 Broadway Stmt INDIVIDUAL 30108 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 301. 7.0300 PLACARDS