Loading...
PMT17-01685 City of Menifee Permit No.: PMT17-01685 29714 HAUN RD. Type: Residential Electrical <A—CCELA MENIFEE,CA 92586 MENIFEE Date Issued: 06/13/2017 PERMIT Site Address: 30345 BRISTOL GATE LN, MENIFEE,CA Parcel Number: 364-360-020 92584 Construction Cost: $6.328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.36KW LOT 50 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description O9t Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK Menifee DATE 05/03/2017 PERMIT/PLAN CHECK NUMBER pffirl Vico TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL [—]MECHANICAL []NEW []PLUMBING [:IRE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit-Plan 1924-2.36kW/9PCS Master Solar Permit No.:PMT14-02629 PROJECTADDRESS 30345 Bristol Gate Ln, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 364-360-020 LOT 50 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL )eremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL )eremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC�N7U(M�BER 728102 LICENSE CLASSIFICATION VALUATION$ L Qom— L SQ FT APPLICANT'S SIGNATURE -DATE wr- CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION i{� `� CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN V� SMIP INVOICE �O PAIDAMOUNT AMOUNT OCASH OCHECK# 0CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK N O CREDITCARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DLNUMBER NOTARIZED LETTER O. YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92596 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION Q J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY HER. MODEL M4Ou(eWt ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 XW Sr VPOpmt1o. LOCATIONS INDICATED BY THE ILLUSTRATION. '�'{/ /��MODULE 9PCS. HYUNDAI HIS-S265RG(265W) Uc01001133 CINSB BUYER: fly—i"V� M IFE INVERTER 9PCS. ENPHASE M215-60-2LL-S22-IG �RRIT ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: pWCDING AND ! SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 PLAN-APPR VAI MOD OTY 9 NA NA City of Menifee BUYER: TILT 23° NA• i Building Dept DATE:_ AZIMUTH I 236° I NA° I NA• MAY 3 0 2017 REVIEWED � Received 'Approval of these pl ins shall approval of,any viola 'on of a regulations and ordin noes. T 16'- ARRAY I7' obsite until completi . 3'FLASHING 3' I ------- ----- -, I 9 SOLAD I I I I I M I I I I (UNDER A WIRE TRANSITION BOX (UNDER ARRAYS I I PV AC DISCONNECT + I EXTERIOR-GARAGE UTILITY METER MAIN SERVICE PANEL '� I (VERIFIED BY BUILDER) UJ r NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 192L ELEVA ION B-LEFT ORIENTATION 4 LO #5 ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:17.4. 55 CORONNA,A.C CA AT THE LAKES 9BO DRIVE.#302 A 92879 REV.# BY DATE I DESCRIPTION namasbe SOLAP DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30345 BRISTOL GATE LN BoCOBD3D9 PLOT PLAN I /Ib'=1'-0' MENIFEE,CA 303.4 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE /CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAR) ASHRAE 2% °C. 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22AG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(SO 225 TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(DC) 48 "Ty TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV.OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(Oc) 239 COMPLIANCE INVERTER SPEC UL1741/IEEEI547 MOD. OPERATING VOLTAGE(VnP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(VOc) MODULE SPEC VOLTS(DO) 38.10 INV.OTY,MAX/BRANCH CCT. INV.QTYec QTY 9 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IHAXBC (IAC-INV.QTYBC) AMPS(AC) B.10 MOD. MAX VOLTAGE (VMAXMOD) (VOC+(TD•COEF)) VOLTS(DC) 41.IB INV.QUANTITY,TOTAL INV.QTYT I CITY 9 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT. IMAXT$ I (IAC-INV.OTYT) I AMPS(AC) 8.10 MOD.SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(DC) 9.00 MOD,MAXIMUM CURRENT(IMAX) (ISO• 1.25) AMPS(DC) 11.25 MIN.AMPACITY REDID.PER NEC (IMAX• 1.25) AMPS(DC) 14.06 C GOnst SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE If visions KEY QTY MANUFACTURER MODEL NOTES TRADE Iofapp 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X ZDA-21'.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER,IPH, 120/240V,200A BLDR.ELEC. 12 I TBO TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 I TBD I TBD I GROUNDING ELECTRODE,69D.47(D) I SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU): (AMPACITY•TEMP.DEBATE • FILL DERATE)vs. REDID(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.Vs.REO'D,CIMAX° 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CARE' AMPACITY W70 TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 20D TYPE DEBATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 B.ID ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20 ` n C #10 CU NM-B COU 40 0.91 1.0 36.40 8.ID TERM 35 35 10.13 20 Mike DOauR CONDUCTOR SCHEDULE Ucl 1001P133oaam0 KEY CONDUCTORS I CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE, I-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10,1410 EGC CU NM-B(ROMEX) I INTERIOR SOLAR C 3410, 1410 EGC I CU NM-B(ROMEX) I INTERIOR SOLAR D CATSE,ETHERNET CABLE I CU CAT5E I INTERIOR SOLAR E 1-06GEC,2010 CEC 690.47(D) I CU BARE I EXTERIOR SOLAR 5 6 II o 7 • o = O SEE NOTE 15 10 O ISC/t O O2 O mO P 3 __ �N 0 G G ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.38SXW LOT*50 : ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA LENNAR 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:17.4.25 AT THE LAKES CORONA.CA 9ZB79 REV.# BY DATE DESCRIPTION namast6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: treet INDIVIDUAL 4571 Ber,CO$ 304 PLOT PLAN 2 NTS 30345 E.CA L GATE LN Boulder,C030704 ELECTRICAL MENIFEE,CA 303.447.0300 �J STRUCTURAL NOTES: Mike Duhult SOLAR CONTRACTOR- 5r VP DpmNoes U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. UcV6 10D1133 Class 8 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. ) 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. �I'I"{e,RI 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(ID OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO.THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE J ne B 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO �feder, INSTALLATION. 1 plans( ELECTRICAL NOTES: GENERAL- O ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR.TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SIR PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING 7 PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LINE MANNER. 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: DESIREE WILLIAMS DATE:17.L.25 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:17.4.25 AT THE LAKES CO NA.CA 92 DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Is u namasGe DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 Street PLOT PLAN 3 NTS 303L5 BRISTOL GATE LN Be3 ldw,D3.4 CO 8030A NOTES MENIFEE,CA 03.d47.0300 iFe Ouhultk�Yt M Sr VPOlxratlons u 01001333 Classa IIENT CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. E if,or ai or city )e kept o the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8. 1 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA REVIEWED BY:SHAUN MARUNA DATE:17.4.25 980 NA.CA I92 DRIVE,#302 AT THE LAKES CORONA,CA 92879 REV.# BY GATE DESCRIPTION b namaste .LA[ DWG TITLE: PAGE#: SCALE: SITE LOCATION: It INDIVIDUAL 4571lda,,C ay304 PLOT PLAN 4 NTS 30345 BRISTOL GATE LN Ba303.4 7. 30304 PLACARDS MENIFEE,CA 303.4g7.0300