PMT17-01684 City of Menifee Permit No.: PMT17-01684
29714 HAUN RD. Type: Residential Electrical
<►CCELA— MENIFEE,CA 92586
MENIFEE Date Issued: 06/13/2017
PERMIT
Site Address: 30357 BRISTOL GATE LN,MENIFEE,CA Parcel Number: 364-360-030
92584 Construction Cost: $6,328.72
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 MARIPOSA
Work: 9 MODULES,2.36KW
LOT 49
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description O0ty Amount
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors In the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bidg_Permit_Template.rpt Page 1 of 1
• • • •
Menifee
DATE 05/03/2017 PERMIT/PLAN CHECK NUMBER M
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: [E]ADDITION []ALTERATION []DEMOLITION []ELECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING ❑RE-ROOF-N UMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2129-2.36kW/9PCS
Master Solar Permit No.: PMT14-02629
PROJECTADDRESS 30357 Bristol Gate Ln, Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER 364-360-030 LOT 49 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 MonteCito Dr.,suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California,Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of Califomia, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.scayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION
VALUATION$ 7Z So,FT L SO.FT
APPLICANT'S SIGNATURE DATE 05/02/2017
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP V�
INVOICE 106/� PAIDAMOUNT
AMOUNT 1 ✓' O CASH O CHECK H O CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT O CASH O CHECK R O CREDITCARD VISA/MC
OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER 0 YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM CITY MFR. MODEL Mike Ou(xult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.385 XW Sr VPOPeratiooa LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 9 PCS.1 HYUNDAI I HiS-S265RG(265W) 1.1,01001133 Cim
BUYER:
INVERTER 1 9 PCS.1 ENPHASE I M215-60-2LL-522-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:_ __ —L"I'V-Jy V F IV ENII
SUB-ARRAY INFORMATION
ARRAY#I ARRAY#2 1 DIN ANI
ARRAY#3
MOD OTY 9 BUILDING NA NA BUYER: I��
TILT 23° NA° NA' AP OV
AZIMUTH ILI° NA' DI NA' DATE:__— _ AN
City Dept
Building
ngg D Dept
REVIEWED
MAY 3 0 2017
e C I V `Approval of thes plans
approval of,any v olation
6'-4• 3 regulations and o inam
jobsite until competion,
_ I �
EA
SOLADEC
i
LL
i
i
i
i
TRANSITION BOX
(UNDER WIRE
i (UNDER ARRAY)
i i PV DISCONNECT
i ( � EXTERIOR-GARAGE A
`V.
UTILITY METER 8 —
MAIN SERVICE PANEL O
(VERIFIED BY BUILDER)
L--
Pon
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ®\
PLAN 2129 ELEVATION A-RIGHT
ORIEN ATION 4
: ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25
MARIPOSA LENNAR
980 I REVIEWED BY:SHAUN MARUNA DATE:17.4.25
AT THE LAKES
CORONA.
A,C CA A 92 DRIVE,#302 879 REV:# BY DATE DESCRIPTION •,
namast6
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Sheet
INDIVIDUAL 30357 BRISTOL GATE LN Boulder,CO 803D4
PLOT PLAN I 1116'=V-0' MENIFEE,CA 3D3.447.0300
SYSTEM LAYOf1T
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV.INPUT V,(VOc MAX) INVERTER SPEC VOLTS(Be) 48
TEMP.DELTA LOW(TELLTA) Tmw-TTEST °C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 �1�/
MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 0.9
MOD. POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER PTC MODULE SPEC WATTS(De) 238 COMPLIANCE INVERTER SPEC UL1741/IEEEI547
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS Wc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(D0 38.10 INV.OTY,MAX/BRANCH CCT. INV.OTYBc OTT 9
MOD, COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CLT. OUTPUT.IMAXBC I (IACINV.QTYBC) I AMPS(AC) 1 8.10
MOD. MAX VOLTAGE(VMAXMOD) (VOc r(TD-COEF)) VOLTS(DC) 41.18 INV.QUANTITY,TOTAL I INV.OTYT I QTY 1 9
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 6.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC°INV.OTYT) I AMPS(AC) 8.10
MOD.SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(DC) 9.00
MOD.MAXIMUM CURRENT(IMAX) (Ise° 1.25) AMPS 00 11.25 no
MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(DC) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 1 15
ELECTRICAL EQUIPMENT SCHEDULE no becon5
KEY QTY MANUFACTURER MODEL NOTES TRADE ny TOVISIOn!
1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 9 ENPHASE M215-60-2LL-S22AG PV INVERTER SOLAR tbl$ et of ap
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24DV,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTER14ET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD FV BREAKER, I x 2OA-ZP,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
II TBO TBD UTILITY METER, IPH, 120/240V,200A BLDR.ELEC.
12 1 TBD TBD I GROUNDING ELECTRODE UFER BLDR.ELEC.
13 TBD I TBD I GROUNDING ELECTRODE,690.47(D) SOLAR
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU): (AMPACITY° TEMP.DEBATE - FILL DERATE)VS. REWD(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS. REQ'D,(IMAX• L25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200
TYPE OERATES 'DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 1 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 140
TERM 25 25 10,13 ZD PV OCPD DEVICE USED AMPS 1 20
B #10 CU NM-B COU 40 0.91 1.0 36.4D 8.10 <
TERM 35 35 10.13 20 \ n
C #10 CU NM-B COU 40 0.91 1.0 36.40 8.10
TERM 35 35 10.13 20 Mike DS,VP�yufEault
CONDUCTOR SCHEDULE UcNI80011330clasae
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1-#12 ENGAGE CABLE.146G,FREE AIR CU TC-ER ARRAY SOLAR
B 3410, 1-410 EGC CU NM-B(ROMEX) INTERIOR SOLAR
C 3410. 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
D CATSE.ETHERNET CABLE CU
CAT"
INTERIOR SOLAR
E 1-#6GEC.2010 CEC 690.47(D) CU BARE EXTERIOR SOLAR
5 6 II
7
I
SEE NOTE 15 10
O
O 2 2DO
O
L'N
D G D._�
13 = E A B C = 12
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.385 KW
LOT#49
LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:17.G.25
MARIPOSA REVIEWED BY:SHAUN MARUNA DATE:17.4.25
CORONA.
AT THE LAKES 9B0 DRIVE.#302
A,C CA A 92879 REV.# BY DATE DESCRIPTION
tanamaste
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4571 Bmatlway Brae(
PLOT PLAN 2 NTS 30357 F.CA L GATE LN eDultler,C0 80304
ELECTRICAL MENIFEE,LA 303.447.0300
--?S),4P-
STRUCTURAL NOTES: Mike Dufault
SOLAR CONTRACTOR- Sr VPOP fioea
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"O.C. UCR 1D01133 Class B
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. pp D
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION �f ^��
MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
O DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO I. be a n
INSTALLATION. ii)e federal,S'
)ed lans mu!
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC6I730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
IQ A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25
MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:17.4.25
CORONNA.A.C CA
AT THE LAKES 980 DRIVE,#302
A 92879 REV.# BY DATE DESCRIPTION
Vtm(=6
SOIaR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
tzoot
INDIVIDUAL 4571ld.r,C a8 304
PLOT PLAN 3 NTS 30357 BRISTOL GATE LN Bo30O. C08D304
NOTES MENIFEE,LA 303.447.0300
Mlke OuhNt
Sr VPOpentlons
LIcg1DD1133 OassO
CAUTION: �T
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
r,or an
it city
kept on the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 0
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8.1 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25
MARIPOSA LENNAR:
980 MONTECITD DRIVE,#302 REVIEWED BY:SHAUN MARUNA 17 DATE: .4.25
AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
vb namast:6
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4571 Br,CO 8
Sirsel
INDIVIDUAL 30357 BRISTOL GATE LN BoWtle480304
PLOT PLAN 4 NTS 04
PLACARDS MENIFEE,CA 303.447.0300