Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01683
City of Menifee Permit No.: PMT17-01683 29714 HAUN RD. Type: Residential Electrical <—ACCELX-3' MENIFEE, CA 92586 MENIFEE Date Issued: 0 6/1 312 01 7 PERMIT Site Address: 30369 BRISTOL GATE LN, MENIFEE,CA Parcel Number: 364-360-029 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.36KW LOT 48 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Amount(Sl Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/.LA PERMIT/PLAN CHECK APPLICATION ��`kMenifee DATE 05/03/2017 PERMIT/PLAN CHECK NUMBER W10 Y/ D TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL [I MECHANICAL ❑NEW ❑PLUMBING ❑RE-RODF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1769-2.36kW/9PCS Master Solar Permit No.: PMT14-02629 PROJECT ADDRESS 30369 Bristol Gate Ln., Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 364-360-029 LOT 48 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)B17-3680 EMAIL )eremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennarcom CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION VALUATION$ l'7 3O^ 54 FT L SQ ST� � FT APPLICANT'S SIGNATURE DATE 05/02/2017 DEPARTMENT DISTRIBUTION V�V CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I SMIP INVOICE PAID AMOUNT AMOUNT OCASH OCHECK# 0CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION .r J/J� BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL Mike Dufault ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 XW Sr VPOperatbns LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9PC5. HYUNDAI HIS-5265RG (265W) Uctl1001133 CWssB BUYER: _ IJ I Y OF ME IFE INVERTER 1 EN SE PHA M215-60-2LL-522-IG R fIl D!�G q D ROOF TYPE TILEE W1 W/COMPOSITE SHINGLE UNDER ARRAY DATE: �' r SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 PLAN APPR V MOD OTY 9 NA NA BUYER: TILT 1 23° 1 NA' I NA' AZIMUTH 1 193° 1 NA' I NA' DATE: City of Menifee REVIEWED Building Deht MAY 3 0 10 r- 'Approval of these pla IS shall Rpp approval of,any viola ' n of an e c e i v e k, regulations and ordinaieft Tf jobsite until comp) 29'-B'ARRAY 30'-6'FLASHING I — —— ————————————— ——— ( SOLADECK ❑ N M TRANSITION WIRE TRANSITION IRE I (UNDER ARRAY) PV AC DISCONNECT 9 EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL,--I Z5 (VERIFIED BY BUILDER) L--------� (w, J r NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ®^^11 1v PLAN 1769 ELEVATION B-LEFT RI T ON 3 LUI9 4 ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:17.4.25 CORONNA,A.C CA AT THE LAKES 980 DRIVE,#3DZ A 92879 REV.# BY DATE I DESCRIPTION 2amaste sai�s DWG TITLE: PAGE#: SCALE: SITE LOCATION: y Street INDIVIDUAL 4871lder,C 83D4 30369 BRISTDL GATE LN Boulder,C080304 PLOT PLAN I/16'=I'-0' MENIFEE,CA SY STEM LAYOUT 3D3.447.0300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Vnc MAX) INVERTER SPEC VOLTS(DO 4B TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 INV.OUTPUT V.(VAC MOM) INVERTER SPEC VOLTS(At) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AD) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DO 265 INV,PHASE-QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL174111EEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(Dc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(VOO MODULE SPEC VOLTS 0c) 38.10 INV. OTY,MAX/BRANCH CCT. INV.OTYac OTY 9 MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V)°C -0.114 BRANCH CCT. OUTPUT,IMAXBC I (IAC°INV.QTYec) AMPS(AG) 1 8.10 MOD.MAX VOLTAGE(VMAXMOD) (VOC+(T0'COEF)) VOLTS 0c) 41.18 INV. QUANTITY,TOTAL I INV.OTYT OTY 1 9 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC°INV.OTYT) I AMPS(AC) 16.10 MOD.SHORT CCT. CURRENT OSO MODULE SPEC AMPS(DO 9.00 ` MOD.MAXIMUM CURRENT(IMAX) 05C• 1.25) AMPS(DC) 11.25 MIN.AMPACITY REQ'D,PER NEC (]MAX• 1.25) AMPS(DC) 14.06 )e CODS) SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE Qvisions KEY OTY MANUFACTURER MODEL NOTES TRADE I of apF 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,I20V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR ID I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II 1 1 1 TBD TBD UTILITY METER, IPH, 120/24DV,200A BLDR.ELEC. 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 1 1 TBD I TBD I GROUNDING ELECTRODE,690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): (AMPACITY•TEMP. DERATE• FILL DEBATE)Vs. REQ'D.(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vS.REQ'D.(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/D TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 20D TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 FV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 LO 36.40 B.IO TERM 35 35 10.13 20 C #10 CU NM-B COU 40 0.91 1.0 36.4D 8.10 TERM 35 35 10.13 20 Mike Dufault Sr VPOperadons CONDUCTOR SCHEDULE Lk#1001133 Class8 KEY CONDUCTORS I CU/AL TYPE I LOCATION I TRADE A I-#12 ENGAGE CABLE.146G,FREE AIR CU TC-ER ARRAY SOLAR B 3410, 1410 EGC CU NM-B(ROMEX) I INTERIOR SOLAR C 3-010, 1-#10 EGC I CU NM-B(ROMEX) I INTERIOR SOLAR D CA75E.ETHERNET CABLE I CU CAT5e I INTERIOR SOLAR E 146GEC.2010 CEC 690.47(D) I CU BARE I EXTERIOR I SOLAR 5 © 11 7 • o • O SEE NOTE 15 10 ® GO O O � aaO 3 I LN G— G� IS= E A B L = 12 ROOF E%TERIDR-GARAGE ELECTRICAL DIAGRAM 2.385 KW LOT#48 ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:17.4.25 CORONNA,A.C CA AT THE LAKES 980 ITO DRIVE.#302 A 92879 REV.# BY DATE DESCRIPTION naM=6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL A6-/t Broadway Street PLOT PLAN 2 NTS 30369 BRISTOL GATE LN BOulder,C0BOOM ELECTRICAL I MENIFEE,CA 303.A47.0300 STRUCTURAL NOTES: Mike SOLAR CONTRACTOR- Sr VP Op Opmtlons 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Uc#2001133 Clan B 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED, PAR 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 41 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS.MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40% # ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED.ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. --O 5e a 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. a federal d plans In ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEL. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NDN-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC6173D. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTORS TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT r. 19)ALL WIRING/RACEWAYSIJUNCTION BOXES WILL BE MARKED PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE: MARIPOSA REVIEWED BY:SHAUN MARUNA DATE:17.4.25 CORONNA,A,C CA AT THE LAKES 980 I DRIVE,#302 A 92879 REV.# BY DATE DESCRIPTION S it masbe sous DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 45]1ldar,C 803M t PLOT PLAN 3 NTS 30369 BRISTOL GATE LN Bo303. C080304 NO]EB MENIFEE,CA 303.A4].0300 Mike I Duhul Sr VP Operatlons UcN fOD1133 Clatte CAUTION: 1ENT POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. l Fly ran e or city Te kept on t e SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8J A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA LENNAR: 980 MONTECITD DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:17.4.25 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •, t0 namasbd SOIA[ DWG TITLE: PAGE#: SCALE: SITE LOCATION: treet INDIVIDUAL 4571Ber,CO8roadway 3D4 PLOT PLAN 4 NITS 303&9 BRISTOL GATE LN Boulder,CO 80304 PLACARDS MENIFEE,CA 3D3.447.0300