PMT17-01682
City of Menifee Permit No.: PMT17-01682 29714 HAUN RD. Type: Residential Electrical �A-CCEL/? MENIFEE, CA 92586 "�t— MENIFEE Date Issued: 06/13/2017 PERMIT Site Address: 30381 BRISTOL GATE LN,MENIFEE,CA Parcel Number: 364-360-028 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.36KW LOT 47 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description 0Y Amount LSl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when In violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pevnit Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE 05/03/2017 PERMIT/PLAN CHECK NUMBER f 1 V J TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL [—]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: QADDITION ❑ALTERATION [-]DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1924-2.36kW/9PCS Master Solar Permit No.: PMT14-02629 PROJECT ADDRESS 30381 Bristol Gate Ln, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 364-360-028 LOT 47 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturN@Iennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lenner Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennarcom CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION VALUATION$ 32872 S LSQFT APPLICANT'S SIGNATURE DATE 05/02/2017 DEPARTMENT DISTRIBUTION V� CITYOFMENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP V_ INVOICE PAID- AMOUNT AMOUNT �� O CASH O CHECK# O CREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0 CASH 0 CHECK# O CREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION -..r�J/J� BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL IIBte Default ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW Sr VPOReraUons LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9PCS. HYUNDAI HIS-S265RG (265W) Ud11001133 Clan F M NIF INVERTER 9 PCS. ENPHASE M215-60-2LL-S22-IG BUYER: ;� y ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: ING ND SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 `1 MOD OTY 9 NA NA BUYER: I'�I AIL APP OVI TILT 23° NA° NA° AZIMUTH I80° NM NM DATE- City of Menifee r 'ILEE $ Building Dept '" ., _ MAY 3 0 20V `Arumaalofthese planssl �Ppt , ation aReceived eguiaions and or nances 16'-5'ARRAY 3' 17'-3'FLASHING jobsite until COMPIE tion. r-- ------------ --� t I I - I I I I I SOLADECK WIRE TRANSITION 1444 I (UNDER ARRAY)X YL PV AC DISCONNECT EXTERIOR-GARAGEUTILITY METER& MAIN SERVILEPANEL (VERIFIED BY BUILDER) r NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 192A ELEVATION C-RIGHT ORIENTATION 3 LOF7 ORIGINAL BY: DESIREE WILLIAMS DATE:I7.4.25 MARIPOSA LENNAR: 980 ITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:I7.A,25 CORONA,CA AT THE LAKES A,CA 92879 REV.# BY GATE DESCRIPTION •� namasGe mus DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 BouldBroer. COa8 Streel 30381 EE,CA L GATE LN BoelUer,0 80304 PLOT PLAN 1/I6'=I'-0' MENIFEE,CA 303.447.030D SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALL UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC 0215-60-2LL-S22-IG TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.Woc MAX) INVERTER SPEC VOLTS(DC) 48 TEMP.DELTA LOW(TDECTA) TMIN-TTEST °C -27 INV. OUTPUT V.(VAc NDM) INVERTER SPEC VOLTS(AC) 240 FET MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD,PART NUMBER MODULE SPEC MIS-S265RG INV. OUTPUT CURRENT, IAc INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(00 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(oc) 23B COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV, GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(CC) 38.10 INV. OTY,MAX/BRANCH CCT. INV.QTYBc OTY 9 MOD.COEFF. VOLT/TEMP(CLEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBC I (IAC•INV.OTYBC) I AMPS(AD) I B.10 MOD.MAX VOLTAGE(VMAXMOD) (Voc+(TD•COEF)) VOLTS(DO 41.1E INV.QUANTITY,TOTAL I INV.QTYT I OTY 1 9 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) B.50 TOTAL SYSTEM OUTPUT,IMUT5 I(IAc•INV.QTYT) I AMPS(Ac) 1 8.10 MOD.SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(oc) 9.00 MOD.MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(m) 11.25 MIN.AMPACITY REQ'D,PER NEC (IMAX• 1.25) AMPS(DC) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(DC) 15 t be COI ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE I IOYI$IO 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR Ii Set ofa 2 9 ENPHASE M215-60-ZLL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URD PV AC DISCONNECT.NEMA 3R.24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X I5A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER, IPH, 1201240V,200A BLDR.ELEC. 12 TBD TBD GROUNDING ELECTRODE UFER BLOR.ELEC. 13 1 1 TBD I TBD I GROUNDING ELECTRODE,690.47(D) I SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS O CONDITION OF USE(COU): (AMPACITY•TEMP. DEBATE• FILL DERATE)VS.REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS. REWD,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 202 TYPE DEBATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 140 TERM 25 25 10.13 2D PV OCPD DEVICE USED AMPS I 20 B #10 CU NM-S COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 2D \ n C #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20 Mike Duault Sr VPOper=Iom CONDUCTOR SCHEDULE UC111001133 CIa%B KEY CONDUCTORS I CU/AL I TYPE I LOCATION I TRADE A 1-#12 ENGAGE CABLE,1-#613,FREE AIR 1 CU !C -ER ARRAY SOLAR B 3-#10, 14HO EGC CU NM-B (ROMEX) INTERIOR SOLAR C 3410, 1-410 EGL I CU I NM-B (ROMEX) I INTERIOR SOLAR D CAT5E,ETHERNET CABLE I CU I CATSE I INTERIOR SOLAR E I46GEC.2010 CEC 690.47(D) I CU I BARE I EXTERIOR I SOLAR 5 5 11 7 • c u O — I SEE NOTE 15 10 O 15© O 2 2GO O N G_ G �G_SI 13= E A B C = 12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM Z.3BSKW LOT#47 LENNAR: ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:17.4.25 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast;6 SOL•P DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Ber,DO 8 tuvet 304 INDIVIDUAL 30381 BRISTOL GATE LN Boulder, 7030304 PLOT PLAN 2 NT5 MENIFEE.CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: Mike Outaul[ SOLAR CONTRACTOR- 5r VP 0pers0ans U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. UcH 1001133 Class B 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION D PARI MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO FV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE,COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF SAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO to be a INSTALLATION. he ledera ,v d plans r ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE LODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC6I730. S)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 16)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT s¢'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHDTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: DESIREE WILLIAMS DATE:I .4.25 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:17.4.25 CORONNA,A,C LA AT THE LAKES 980 I DRIVE,#3D2 A 92879 REV.# BY DATE DESCRIPTION Vuasul§ SOlir OWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4671 Broatl__ 304 PLOT PLAN 3 NTS 30381 BRISTOL GATE LN Bo303.4 C080304 NOTES MENIFEE.CA 303.M].0300 Mike Oufaull Sr VP OperanoM Licp 1001133 Oau B CAUTION: ,ENT POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. or nor,or n city uz kept on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-B77-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8.1 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: DESIREE WILLIAMS DATE:17.4.25 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:17.4.25 AT THE LAKES CO NA,CA 92 DRIVE,#3@ CORONA,CA 92879 REV.# BY DATE DESCRIPTION ma ti st SOLnR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4577 Br,CO 8 Street INDIVIDUAL 30381 BRISTOL GATE LN Boulder, 00304 PLOT PLAN 4 NTS 04 PLACARDS MENIFEE,CA 3D3.447.0300