Loading...
PMT17-01295 City of Menifee Permit No.: PMT17-01295 29714 HAUN RD. Type: Residential Electrical <A-CCEL/? MENIFEE, CA 92586 MENIFEE Date Issued: 08/01/2017 PERMIT Site Address: 29111 MORAGA ST, MENIFEE,CA 92584 Parcel Number: Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR MODEL TR 31582 HERITAGE HEIGHTS Work: 8 MODULES,2.12KW LOT 121 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtv Amount I81 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_aldg_Peonit_Template.rpt Page 1 of 1 APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ✓❑RESIDENTIAL []MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1782-2.12 kW/8 PCS Master Solar Permit No.: PMT17-00129 PROJECT ADDRESS 29111 Moraga St,Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER LOT 121 TRACT 31582 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acaytuni@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ L SQ FT APPLICANT'S SIGNATURE DATE 04/11/2017 CITY STAFF USE ONLY - .. .. DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP INVOICE I PAID AMOUNT AMOUNT I 1 0CASH 0 CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Hawn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.120 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8 PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 1 8 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I CONC.TILE DATE: SUB-ARRAY INFORMATION -s 17 OF ME NIFI ARRAY#1 ARRAY#2 1 ARRAY 43 ARRAY#4 MOD OTY B NA NA NA BUYER: S I DING ND TILT 23° NA' I NA- NA' AZIMUTH 232° NA' NA' NA° DATE: VA City Of Menitee Building DePt RrVIEIAIED 114 APR .orovalof these p nssha Recelvftdl approval of,anyviola ion of, regulations and ordin inces. ' jobsite until completil , a a 9 m « V SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) Off° PV AC DISCONNECT EXTERIOR-GARAGE O UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) 1 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1782 ELEVATION A-LEFT /t® ORIENTATION 3 LOT# 121 LENNAR: ORIGINAL BY:KIM ABCOUWER DATE:17.04,07 HERITAGE HEIGHTS 980 REVIEWED BY:JIM PARKS DATE:17.04,07 CORONNA,A.C LA A 92879 DRIVE,#302 REV.# BY I DATE I DESCRIPTION V , namasG6 5MAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 13madwe7 Sl t INDIVIDUAL 29111 MDRAGA STREET BouMer,CO 8D304 PLOT PLAN 1 1/16-=1'-0' MENIFEE.CA 3D3.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALL UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN •C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS.(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VBC MAX) INVERTER SPEC VOLTS(BC) LB TEMP.DELTA LOW(ToELTA) THIN-TTEST °C -27 INV, OUTPUT V,(Vac NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(DO 265 INV. PHASE QUANTITY INVERTER SPEC PHASE ETY MOD. POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL17LI/IEEEISL7 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DO 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(DC) 38.10 INV.OTY,MAX/BRANCH CCT, NV.QTYBC OTY 8 MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBC (IAC•INV.QTYBC) I AMPS(AC) 17.20 MOD.MAX VOLTAGE(VMAXMOO) (VOC♦(TD•COEF)) VOLTS(BC) 41.18 INV.QUANTITY,TOTAL INV.OTYT OTY 8 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 8.50 TOTAL SYSTEM OUTPUT.IMAXTS (IAC•INV.OTYT) AMPS(AU 7.20 MOD.SHORT CCT. CURRENT(ISO MODULE SPEC AMPS(DC) 9.00 MOD.MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(DC) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(DC) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE r e consl 1 8 HYUNDAI HIS-SZ65RG(265W) PV MODULE SOLAR 2 8 ENPHASE M215-60-2LL-SZZ-IG PVINVERTER SOLAR jr VI$IOII! 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR t of a 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV.30A SOLAR I PF 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD I20V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATE PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR B NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IF(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBO PV BREAKER. I x 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD THD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBO 78D UTILITY METER, IPH, 120/240V,200A BLDR.ELEC. 12 I 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY•TEMP. DERATE •FILL DEBATE) vs. REO'D(IMAX) =PER UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vS. REO'D.(IMAX- 1.25) CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL' AMPACITY W/O TEMP. FILL RESULT REQ'D OCD AMPS 200 TYPE DERATES DEBATE DERATE (A) (A) USED(A) ECT AMPS 200 A *12 CU THWN-2 COU 3D 0.76 I.0 22.80 7.20 ER NEC AMPS LO TERM 25 25 9.00 20 E USED AMPS 20 B #10 CU NM-B COU 40 D.91 1.0 36.40 7.20 INTERCONNECTION CALLS: TERM 35 35 9.00 20 O.9A K S(MODS)= 7.20A OF CURRENT C #10 CU NM-B COU 40 0.91 1.0 36.40 7.20 7.20A x 1.25= 9.o0A TERM 35 35 9.00 20 TIE-IN WITH A EOA72P E SPACE PV SACKFEEO BREAKER CONDUCTOR SCHEDULE KEY 1 CONOIICTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE, 146G,FREE AIR I CU I TC-ER ARRAY SOLAR B 1 3-#10. 1-#10 EGC CU I NM-B(ROMEX) INTERIOR I SOLAR 5 © II C 3410. 1410 EGC CU I NM-B(ROMEX) INTERIOR I SOLAR D CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR 0° c ® O - SEE NOTE 15 10 O15AIlP O 0 O OI zoazP 3 L �N G G G A B C - 12 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.120 KW LOT#121 LENNAR: ORIGINAL BY:KIM ABCOUWER DATE:I7.OL.O] HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE:I].OL.D7 980 MONTECITO DRIVE.#302 CORONA.CA 92879 REV.# BY DATE I DESCRIPTION Q�namastEe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4M Bmadmy Sheet INDIVIDUAL 29111 MORAGA STREET BOOIEar,CO 803M PLOT PLAN 2 NTS MENIFEE,LA 303.007.030D ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- O ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION ���, MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(z)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- • O DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. be.. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. fedel ,J plans ELECTRICAL NOTES: GENERAL- O ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. W NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL17D3,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS, 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A.DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES, 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING, BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT j7'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:KIM ABCOUWER DATEI7.DL.D7 HERITAGE HEIGHTS LEN14AR: REVIEWED BY:JIM PARKS DATE17.04.07 980 MONTECITO DRIVE.#302 CORONA,CA 92B79 REV.# BY DATE DESCRIPTION •� Qu namaste SOLA[ DWG TITLE: PAGE#: I SCALE: SITE LOCATION: SIVeat INDIVIDUAL 4577 Broadway 0304 PLOT PLAN 3 NTS 29111 MORAGA STREET Boulder,7. 30304 NOTES MENIFEE,CA 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE iI NT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ,I W E Io a e or city c •e kept onthe SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER A MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 7.20A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:KIM ABCDUWER DATE:17.04.07 LENNAR: HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE:I7.OL.07 CO NA.CA I92 DRIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION `d namast;e SOLAR DWG TITLE: PAGE*: I SCALE: SITE LOCATION: eet INDIVIDUAL 4571 B.,.CO O 304 PLOT PLAN 4 NTS 291II MORAGA STREET BO3D3.44 030309 PLACARDS MENIFEE,CA 303.467.0300