PMT17-01294
City of Menifee Permit No.: PMT17-01294 29714 HAUN RD. Type: Residential Electrical �ACCELA? MENIFEE, CA 92586 °"'" MENIFEE Date Issued: 0 8101/2 01 7 PERMIT Site Address: 29097 MORAGA ST, MENIFEE,CA 92584 Parcel Number: Construction Cost: $5,613.76 Existing Use: Proposed Use: Description of SOLAR MODEL TR 31582 HERITAGE HEIGHTS Work: 8 MODULES,2.12KW LOT 120 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Oft Amount f51 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit Templatespt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN APPLICATION "Menifee DATE DATE PERMIT/PLAN CHECK NUMBER 1 TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1874-2,12 kW/8 PCS Master Solar Permit No.:PMT17-00129 PROJECT ADDRESS 29097 Moraga St,Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER LOT 120 TRACT 31582 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennaccom CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ 6 �.7 S L SO FT APPLICANT'S SIGNATURE DATE 04/11/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION YG �� CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I I SMIP INVOICE PAID AMOUNT AMOUNT 1 0CASH 0CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.120 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 8 VC1.1 HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 1 8 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I CONIC.TILE DATE: SUB-ARRAY INFORMATION , °YI ARRAY#1 ARRAY#2 1 ARRAY#3 ARRAY#4 MOD OTY B NA iA NA BUYER: uttt(-DIN AN TILT I IB° I NA' I NA- NA° AZIMUTH 262° NA' NA° NA' DATE: City of Menifee Ar IF R01 Building Dept APR 2 6 2017 22"`JIEWE C Receives. "Approval ofthes plans aporoval of,any v olal;ion re;Nlations and o inancl jcbslte until camp etion, a V i SOLADECK WIRE rd TRANSITION BOX t (UNDER ARRAY) Q PV AC DISCONNECT EXTERIOR-GARAGE d UTILITY METER 8 , MAIN SERVICE PANEL (VERIFIED BY BUILDER) Ki'. IA NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1874 ELEVATION 8-RIGHT ORIENTATION 3 LOT#120 LENNAR: ORIGINAL BY:KIM ABCOUWER DATE:17.D4.07 HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DA7E:17.04.D7 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# aV DATE I DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Breatl yStreet INDIVIDUAL 29097 MORAGA STREET Boulder,CO 80304 PLOT PLAN 1/16'= 1'-0' MENIFEE,CA 301,147.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE /CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(DO 48 TEMP,DELTA LOW(TDELTA) THIN-TTEsi 'C -27 INV. OUTPUT V.(VAC MOM) INVERTER SPEC VOLTS(Ac) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,AC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE 1 MOD.POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL174I1 EEEI547 [G' MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED rG MOD.OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(oc) 38.10 INV. QTY.MAX/BRANCH CCT. INV.OTYBC OTY 8 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT. OUTPUT, IMAXBC I (IAC-INV.OTYBC) AMPS(AC) 7.20 MOD.MAX VOLTAGE(VMAXMOD) (VOC♦(TD-COEF)) VOLTS(DC) 41.18 INV. QUANTITY,TOI I INV.QTYT OTY 8 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(Dc) 8.50 TOTAL SYSTEM OUTPUT.IMAXTS (lac'INV.QTYT) AMPS(AC) 7.20 MOD.SHORT CCT. CURRENT (ISC) MODULE SPEC AMPS(DO 9.00 MOD.MAXIMUM CURRENT(IMAX) (ISc- 1.25) AMPS(DO 11.25 MIN.AMPACITY REO'D.PER NEC (IMAX' 1.25) AMPS 00 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 1 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE I 8 HYUNDAI HIS-SZ65RG(265W) PV MODULE SOLAR I Tot be I 2 8 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR J y NrOVI'. 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA SR,240V.30A SOLAR 'I 1$Set 0 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 I TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR. ELEC. 11 1 I 1 TBD 1 TBD 1 UTILITY METER,IPH, 120/240V,ZOOA BLDR. ELEC. 12 1 I 1 TBD I TED I GROUNDING ELECTRODE LIFER BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU): I (AMPACITY=TEMP. DERATE •FILL DERATE) VS. REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS. VS. REQ'D,(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER KEY SRE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS ZOD A #12 CU THWN-2 COU 30 D,76 1.0 22.80 7.20 ALLOWED PV PER NEC AMPS 40 TERM 25 25 9.00 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 7.20 INTERCONNECTION CALCS: TERM 35 35 9.00 20 0.9A X 8(MODS). 7,20A OF CURRENT C #10 CU NM-B COU 40 0.91 I.D 36.40 7.20 7,20A X 1.25= 9.00A TERM 35 35 9.00 20 TIE-IN WITH A 2012 SPACE PV BACXFEEO BREMER CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE p 1-#12 ENGAGE CABLE,I-#66,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10, I-A CU NM-B(ROMEX) INTERIOR SOLAR 5 © II C 3-#10, 1-#10 EGC CU NM-B(RDMEX) INTERIOR SOLAR D CAT5E,ETHERNET CABLE I CU CAT5E INTERIOR I SOLAR IO — SEE NOTE 15 10 4O15A/IP 2 0 O O O 2oA/2P 3 �N G G G� I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.120 KW LOT#120 ORIGINAL BY:KIM ABCOUWER DATE:17.04.07 HERITAGE HEIGHTS LENNAR: 980 MONTELITO DRIVE,#302 REVIEWED BY:JIM PARKS I DATE:17.04.07 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasGe iOUR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 B..d.y Street INDIVIDUAL 29097 MORAGA.STREET Boulder,CO W304 PLOT PLAN 2 NITS MENIFEE,CA 303.447,0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER INCH(L)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWD INCHES In BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 09 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. COMPOSITION SHINGLE I SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. (:I d to be e Jr the fede irol edplam ELECTRICAL NOTES: GENERAL- Q ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2D14 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. ID)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT, IS)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. (8)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT r. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:KIM ABCOUWER DATE77.04.07 HERITAGE HEIGHTS LENNAR: REVIEWED BY:JIM PARKS DATEd].04.07 9BO MONTECITO DRIVE.#302 . CORONA,CA 92879 REV.# BY DATE I DESCRIPTION namaste SOLA[ DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 45]IIdw,CO 304 PLOT PLAN 3 NTS 29097 E.CA STREET Bo303.4 7. 30904 NOTES MENIFEE.LA 303.g4].0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS E� ARE LOCATED AS SHOWN. it for, ^ t to or be ke:. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE U71LRY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 7.20A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY:KIM ABCOUWER DATE:17.04.07 HERITAGE HEIGHTS 9BD MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS DATE:17.04. 77 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namasbe 301A' DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29097 MORAGA STREET Boulder.CO 80304 PLOT PLAN A NTS MENIFEE,CA 303.447.0300 PLACARDS