Loading...
PMT17-01293 City of Menifee Permit No.: PMT17-01293 29714 HAUN RD. Type: Residential Electrical ACC iuA—> MENIFEE, CA 92586 MENIFEE Date Issued: 08/01/2017 PERMIT Site Address: 29083 MORAGA ST, MENIFEE,CA 92584 Parcel Number: Construction Cost: $8,420.64 Existing Use: Proposed Use: Description of SOLAR MODEL TR 31582 HERITAGE HEIGHTS Work: 12 MODULES, 3.18KW LOT 119 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE , CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Oft( Amount 181 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 C APPLICATION `Menifee DATE PERMIT/PLAN CHECK NUMBER I� trj TYPE: [—]COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [—]SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUM BER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2686-3.18kW/12 PCS Master Solar Permit No.: PMT17-00129 PROJECTADDRESS 29083 Moraga St,Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER LOT 119 TRACT 31582 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennarcom APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturd@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION '4RB VALUATION$ 0 1, q2O- 6Y SQ FT L SQ FT APPLICANT'S SIGNATURE DATE 04/11/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION {{LL CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING GINEERING FIRE GREEN l SMIP INVOICE q PAID AMOUNT AMOUNT l O CASH 0 CHECK# =%CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# 0CREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.citycfnlenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED IT OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.180 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 12 PCS.1 HYUNDAI HIS-SZ65RG(265W) BUYER: INVERTER 12 PCS.1 ENPHASE I 1215-60-21L-S22-I13 ROOF TYPE CONE.TILE DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 ARRAY#4 jr MEN MOD OTY 1 12 NA NA NA BUYER: TILT 23° NA' NA' NA° ING A AZIMUTH 13D° NA' NA. NA' DATE:— M City of Menifee PLAID AF PRO Building Dept APR 2 6 2017 REVIEW 10'-10, 3' g *Approval oftliese pla approval of,an I violat regulations an I ordina jobsite until cc Tipletic a P SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT O EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) 4000 NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION C-RIGHT ®� ORIENTATION 4 LOT# 119 LENNAR: ORIGINAL BY:KIM ASCOUWER DATE:17-04.07 HERITAGE HEIGHTS 980 MONTELITO DRIVE.#302 REVIEWED BY:JIM PARKS I DATE:17-04.07 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast;e It- SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4 1 B.a.y Street INDIVIDUAL 29003 MORAGA STREET B..Id.,,CO BD304 PLOT PLAN 1 1/16'=1'-0' MENIFEE.CA 303.447.03DO SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AO) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV..INPUT V.(Voc MAX) INVERTER SPEC VOLTS(OC) 48 TEMP.DELTA LOW(TDELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 c MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAc INVERTER SPEC AMPS(AC) 0.9 FE1 MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE MOD. POWER PTC MODULE SPEC WATTS(DO 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC IS MOD. OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(Dc) 38.10 INV.OTY,MAX/BRANCH CCT. INV-OTYA CITY 12 MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -D.114 BRANCH CCT. OUTPUT, MANIC I(IAc°INV.QTYBc) I AMPS(AC) I ID.BO MOD. MAX VOLTAGE(VMAXMDD) (VOC♦(TD•COEF)) VOLTS(OC) 41.18 INV.QUANTITY,TOTAL I INV.QTYT I QTY 1 12 MOD, OPERATING CURRENT(IMP) MODULE SPEC AMPS(oc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC°INV.QTYT) AMPS(AC) IO.BO MOD.SHORT CCT. CURRENT(ISO) MODULE SPEC AMPS(DC) 9.00 MOD.MAXIMUM CURRENT(IMAX) (ISC° 1.25) AMPS(DC) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX° 1.25) AMPS CDC) 14.D6 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE (1al not be KEY OTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR )f a v;17(GV 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR S. b15$EtI 3 1 RSTC/SOLADECK 0706-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 0 NOTE CURER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBO TBO SERVICE PANEL,MI N. 125A BUS BLDR.ELEC. II I TBD TBO UTILITY METER, IPH. 120/240V.200p BLDR.ELEC. 12 1 I 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE (COO): (AMPACITY - TEMP. DERATE•FILL DERATE) VS. REOD(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM). EDERATES ERMINALS. vs. READ.([MAX° 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION dTYPE TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 THWN-2 0.16 1.0 22.80 10.BO ALLOWED PV PER NEC AMPS 40 25 13.50 20 PV OCPD DEVICE USED AMPS 20 NM-B D.91 0 36.40 10.80 INTERCONNECTION CALLS:35 13.50 20 12(MODS)= IO.B04 OF CLBRENT NM-B 091LO36.40 IO.BD ID.BDA x2 = IssOA 35 3.50 20 TIE-IN WITH A 20A/2P 2 SPACE PV BACXFEED BREAKER CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL TYPE LOCATION TRADE p L#12 ENGAGE CABLE. 1-#6G,FREE AIR CU TC-ER ARRAY SOLR B 3-#10,1d 10 EGL CU SO NM-B(ROMEX) INTERIOR LAAR 5 G I C I 34HO.I-AHO EGC I CU NM-S(ROMEX) INTERIOR I SOLAR D I CATSE,ETHERNET CABLE I CU CAT55 INTERIOR I SOLAR M — SEE NOTE 15 10 8 O4 sO 9 O O � �OP IN G G G� A B C — 12 I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 5.IBOKW LOT# 119 ORIGINAL BY:KIM ABCOUWER DATE: LENNAR: 17.04.07 HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE:17.D4.D7 93D MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Z2nannasr6 SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: treet INDIVIDUAL 9571&O,COarAny 3D4 PLOT PLAN 2 NTS 29083 E.CA STREET Boulder,CO B00DA ELECTRICAL MENIFEE.CA 303.447.030D STRUCTURAL NOTES: SOLAR CONTRACTOR- O ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT, 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION VERSION 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE QUARTER YINCH({^)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND D PARI THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN AD'. ROOFING CONTRACTOR- O DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(1')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO, t BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED TO BE INSTALLED OVER TILE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 1 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE UNLESS PV ARRAY IS SPECIFIED.TO BE INSTALLED OVER TILE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. U ((to be B of the fede nro ied p:an! ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND.LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC7CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. 7)ENPHASE MICROINVERTERS.ARE TESTED AND LISTED FOR COMPLIANCE WITH RAPID SHUTDOWN REQUIREMENTS OF SECTION 690.12 OF THE 2014 NEC. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULI703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. Ill)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 1D'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY:KIM ABCOUWER DATE17.04.0 980 MONTECITO DRIVE.#302 7 HERITAGE HEIGHTS : REVIEWED BY:JIM PARKS DATE17.04.07 B0 CORONA,CA 9Z879 REV.# BY DATE DESCRIPTION namast:e SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL A571 Ber,CO 8 Street PLOT PLAN 3 NTS 29OB3 E,CA STREET Boulder, 7O B030A NOTES MENIFEE,CA 303.44].0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS IENT ARE LOCATED AS SHOWN. 110 Led ��DAp Of I it ror,or a� ate or city d be:cept on t1 SOLAOECK WIRE TRANSITION BOX (CNDER ARRAY) pV AC DISCONNECT EY.TERIDR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.80A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY:KIM ABCOUWER DATE LENNAR: :17.04.D7 HERITAGE HEIGHTS REVIEWED BY:JIM PARKS DATE:17.04.07 9110 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION t;51namas156 SOLAE DWG TITLE: PAGE#: SCALE: SITE LOCATION: keet INDIVIDUAL 4371 Ber,CO 304 PLOT PLAN 4 NTS 29083 E,CA STREET BODBIBI,C080304 PLACARDS MENIFEE,CA 303.447.0300